Search Results - "Harty, P"

Refine Results
  1. 1

    High-Fidelity Quantum Logic Gates Using Trapped-Ion Hyperfine Qubits by Ballance, C J, Harty, T P, Linke, N M, Sepiol, M A, Lucas, D M

    Published in Physical review letters (05-08-2016)
    “…We demonstrate laser-driven two-qubit and single-qubit logic gates with respective fidelities 99.9(1)% and 99.9934(3)%, significantly above the ≈99% minimum…”
    Get full text
    Journal Article
  2. 2

    High-Fidelity Preparation, Gates, Memory, and Readout of a Trapped-Ion Quantum Bit by Harty, T P, Allcock, D T C, Ballance, C J, Guidoni, L, Janacek, H A, Linke, N M, Stacey, D N, Lucas, D M

    Published in Physical review letters (28-11-2014)
    “…We implement all single-qubit operations with fidelities significantly above the minimum threshold required for fault-tolerant quantum computing, using a…”
    Get full text
    Journal Article
  3. 3

    High-Fidelity Trapped-Ion Quantum Logic Using Near-Field Microwaves by Harty, T P, Sepiol, M A, Allcock, D T C, Ballance, C J, Tarlton, J E, Lucas, D M

    Published in Physical review letters (30-09-2016)
    “…We demonstrate a two-qubit logic gate driven by near-field microwaves in a room-temperature microfabricated surface ion trap. We introduce a dynamically…”
    Get full text
    Journal Article
  4. 4

    Hybrid quantum logic and a test of Bell’s inequality using two different atomic isotopes by Ballance, C. J., Schäfer, V. M., Home, J. P., Szwer, D. J., Webster, S. C., Allcock, D. T. C., Linke, N. M., Harty, T. P., Aude Craik, D. P. L., Stacey, D. N., Steane, A. M., Lucas, D. M.

    Published in Nature (London) (17-12-2015)
    “…Web summaryHarnessing the entanglement of different ionic species could bring new flexibility in quantum computing, and now two groups independently…”
    Get full text
    Journal Article
  5. 5

    Coherent Control of Trapped-Ion Qubits with Localized Electric Fields by Srinivas, R, Löschnauer, C M, Malinowski, M, Hughes, A C, Nourshargh, R, Negnevitsky, V, Allcock, D T C, King, S A, Matthiesen, C, Harty, T P, Ballance, C J

    Published in Physical review letters (14-07-2023)
    “…We present a new method for coherent control of trapped ion qubits in separate interaction regions of a multizone trap by simultaneously applying an electric…”
    Get full text
    Journal Article
  6. 6

    Probing Qubit Memory Errors at the Part-per-Million Level by Sepiol, M. A., Hughes, A. C., Tarlton, J. E., Nadlinger, D. P., Ballance, T. G., Ballance, C. J., Harty, T. P., Steane, A. M., Goodwin, J. F., Lucas, D. M.

    Published in Physical review letters (13-09-2019)
    “…Robust qubit memory is essential for quantum computing, both for near-term devices operating without error correction, and for the long-term goal of a…”
    Get full text
    Journal Article
  7. 7

    High spatial resolution dosimetric response maps for radiotherapy ionization chambers measured using kilovoltage synchrotron radiation by Butler, D J, Stevenson, A W, Wright, T E, Harty, P D, Lehmann, J, Livingstone, J, Crosbie, J C

    Published in Physics in medicine & biology (21-11-2015)
    “…Small circular beams of synchrotron radiation (0.1 mm and 0.4 mm in diameter) were used to irradiate ionization chambers of the types commonly used in…”
    Get more information
    Journal Article
  8. 8

    Absolute dosimetry on a dynamically scanned sample for synchrotron radiotherapy using graphite calorimetry and ionization chambers by Lye, J E, Harty, P D, Butler, D J, Crosbie, J C, Livingstone, J, Poole, C M, Ramanathan, G, Wright, T, Stevenson, A W

    Published in Physics in medicine & biology (07-06-2016)
    “…The absolute dose delivered to a dynamically scanned sample in the Imaging and Medical Beamline (IMBL) on the Australian Synchrotron was measured with a…”
    Get more information
    Journal Article
  9. 9

    Preclinical TSPO Ligand PET to Visualize Human Glioma Xenotransplants: A Preliminary Study by Buck, Jason R, McKinley, Eliot T, Fu, Allie, Abel, Ty W, Thompson, Reid C, Chambless, Lola, Watchmaker, Jennifer M, Harty, James P, Cooper, Michael K, Manning, H Charles

    Published in PloS one (30-10-2015)
    “…Current positron emission tomography (PET) imaging biomarkers for detection of infiltrating gliomas are limited. Translocator protein (TSPO) is a novel and…”
    Get full text
    Journal Article
  10. 10

    Absolute x-ray dosimetry on a synchrotron medical beam line with a graphite calorimeter by Harty, P. D., Lye, J. E., Ramanathan, G., Butler, D. J., Hall, C. J., Stevenson, A. W., Johnston, P. N.

    Published in Medical physics (Lancaster) (01-05-2014)
    “…Purpose: The absolute dose rate of the Imaging and Medical Beamline (IMBL) on the Australian Synchrotron was measured with a graphite calorimeter. The…”
    Get full text
    Journal Article
  11. 11

    Dark-resonance Doppler cooling and high fluorescence in trapped Ca-43 ions at intermediate magnetic field by Allcock, D T C, Harty, T P, Sepiol, M A, Janacek, H A, Ballance, C J, Steane, A M, Lucas, D M, Stacey, D N

    Published in New journal of physics (12-02-2016)
    “…We demonstrate simple and robust methods for Doppler cooling and obtaining high fluorescence from trapped 43Ca+ ions at a magnetic field of 146 Gauss. This…”
    Get full text
    Journal Article
  12. 12

    Assessment of leakage doses around the treatment heads of different linear accelerators by Lonski, P, Taylor, M L, Franich, R D, Harty, P, Kron, T

    Published in Radiation protection dosimetry (01-12-2012)
    “…Out-of-field doses to untargeted organs may have long-term detrimental health effects for patients treated with radiotherapy. It has been observed that…”
    Get full text
    Journal Article
  13. 13

    Activated polymorphonuclear cells promote injury and excitability of dorsal root ganglia neurons by Shaw, S.K., Owolabi, S.A., Bagley, J., Morin, N., Cheng, E., LeBlanc, B.W., Kim, M., Harty, P., Waxman, S.G., Saab, C.Y.

    Published in Experimental neurology (01-04-2008)
    “…Therapies aimed at depleting or blocking the migration of polymorphonuclear leukocytes (PMN or neutrophils) are partially successful in the treatment of…”
    Get full text
    Journal Article
  14. 14

    Comparison of the NMIJ and the ARPANSA standards for absorbed dose to water in high-energy photon beams by Shimizu, M, Morishita, Y, Kato, M, Tanaka, T, Kurosawa, T, Takata, N, Saito, N, Ramanathan, G, Harty, P D, Oliver, C, Wright, T, Butler, D J

    Published in Radiation protection dosimetry (01-04-2015)
    “…The authors report the results of an indirect comparison of the standards of absorbed dose to water in high-energy photon beams from a clinical linac and…”
    Get full text
    Journal Article
  15. 15

    Direct MC conversion of absorbed dose to graphite to absorbed dose to water for 60Co radiation by Lye, J E, Butler, D J, Franich, R D, Harty, P D, Oliver, C P, Ramanathan, G, Webb, D V, Wright, T

    Published in Radiation protection dosimetry (01-06-2013)
    “…The ARPANSA calibration service for (60)Co gamma rays is based on a primary standard graphite calorimeter that measures absorbed dose to graphite. Measurements…”
    Get full text
    Journal Article
  16. 16

    Body composition and metabolic factors in obese children and adolescents by Tershakovec, A.M, Kuppler, K.M, Zemel, B.S, Katz, L, Weinzimer, S, Harty, M.P, Stallings, V.A

    Published in International Journal of Obesity (01-01-2003)
    “…OBJECTIVE: Body composition is associated with metablic factors in adults; however, data are limited regarding obese children. This study was undertaken to…”
    Get full text
    Journal Article
  17. 17
  18. 18

    Navigating the perils and pitfalls of pediatric forensic postmortem imaging in the United States by Harty, Mary P., Gould, Sharon W., Harcke, Howard T.

    Published in Pediatric radiology (01-05-2021)
    “…Postmortem CT is widely used in the general adult and military populations. It is used extensively in pediatric death investigations in Europe and Asia, but…”
    Get full text
    Journal Article
  19. 19

    Current utilization of pediatric postmortem imaging in North America: a questionnaire-based survey by Harty, Mary P., Gould, Sharon W., Arthurs, Owen J., Miller, Elka, Harcke, H. Theodore

    Published in Pediatric radiology (01-05-2023)
    “…Background Postmortem imaging is used more widely as the number of conventional autopsies has decreased over the last several decades. It is widely accepted in…”
    Get full text
    Journal Article
  20. 20

    Maturation of pelvic ossification centers on computed tomography in normal children by Grissom, Leslie E., Harty, Mary P., Guo, Grace W., Kecskemethy, Heidi H.

    Published in Pediatric radiology (01-12-2018)
    “…Background The pelvis is composed of three paired primary ossification centers: the pubis, the ischium and the ilium. During maturation, multiple secondary…”
    Get full text
    Journal Article