  1. 1

    Comparison of Macintosh, Truview EVO2®, Glidescope®, and Airwayscope® laryngoscope use in patients with cervical spine immobilization by Malik, M.A., Maharaj, C.H., Harte, B.H., Laffey, J.G.

    Published in British journal of anaesthesia : BJA (01-11-2008)
    “…The purpose of this study was to evaluate the effectiveness of the Pentax AWS®, Glidescope®, and the Truview EVO2®, in comparison with the Macintosh…”
    Get full text
    Journal Article
  2. 2

    Randomized controlled trial of the Pentax AWS®, Glidescope®, and Macintosh laryngoscopes in predicted difficult intubation by Malik, M.A., Subramaniam, R., Maharaj, C.H., Harte, B.H., Laffey, J.G.

    Published in British journal of anaesthesia : BJA (01-11-2009)
    “…The purpose of this study was to determine the potential for the Pentax AWS® and the Glidescope® to reduce the difficulty of tracheal intubation in patients at…”
    Get full text
    Journal Article
  3. 3

    Evaluation of the Airtraq® and Macintosh laryngoscopes in patients at increased risk for difficult tracheal intubation by Maharaj, C. H., Costello, J. F., Harte, B. H., Laffey, J. G.

    Published in Anaesthesia (01-02-2008)
    “…Summary The Airtraq®, a novel single use indirect laryngoscope, has demonstrated promise in the normal and simulated difficult airway. We compared the ease of…”
    Get full text
    Journal Article
  4. 4

    Comparison of the C‐MAC® videolaryngoscope with the Macintosh, Glidescope®, and Airtraq® laryngoscopes in easy and difficult laryngoscopy scenarios in manikins by McElwain, J., Malik, M.A., Harte, B.H., Flynn, N.M., Laffey, J.G.

    Published in Anaesthesia (01-05-2010)
    “…Summary The C‐MAC® comprises a Macintosh blade connected to a video unit. The familiarity of the Macintosh blade, and the ability to use the C‐MAC as a direct…”
    Get full text
    Journal Article
  5. 5

    A comparison of tracheal intubation using the Airtraq® or the Macintosh laryngoscope in routine airway management: a randomised, controlled clinical trial by Maharaj, C. H., O'Croinin, D., Curley, G., Harte, B. H., Laffey, J. G.

    Published in Anaesthesia (01-11-2006)
    “…Summary The Airtraq® laryngoscope is a novel single use tracheal intubation device. We compared the Airtraq® with the Macintosh laryngoscope in patients deemed…”
    Get full text
    Journal Article
  6. 6

    Comparison of the Glidescope®, the Pentax AWS®, and the Truview EVO2® with the Macintosh laryngoscope in experienced anaesthetists: a manikin study by Malik, M.A., O’Donoghue, C., Carney, J., Maharaj, C.H., Harte, B.H., Laffey, J.G.

    Published in British journal of anaesthesia : BJA (01-01-2009)
    “…The Pentax Airwayscope®, the Glidescope®, and the Truview EVO2® constitute three novel laryngoscopes that facilitate visualization of the vocal cords without…”
    Get full text
    Journal Article
  7. 7

    Evaluation of intubation using the Airtraq® or Macintosh laryngoscope by anaesthetists in easy and simulated difficult laryngoscopy – a manikin study by Maharaj, C. H., Higgins, B. D., Harte, B. H., Laffey, J. G.

    Published in Anaesthesia (01-05-2006)
    “…Summary The Airtraq® Laryngoscope is a novel intubation device which allows visualisation of the vocal cords without alignment of the oral, pharyngeal and…”
    Get full text
    Journal Article
  8. 8

    Comparison of three cuffed emergency percutaneous cricothyroidotomy devices to conventional surgical cricothyroidotomy in a porcine model by Murphy, C, Rooney, S.J., Maharaj, C.H., Laffey, J.G., Harte, B.H.

    Published in British journal of anaesthesia : BJA (01-01-2011)
    “…Emergency cricothyroidotomy is a potentially life-saving procedure in the ‘cannot intubate cannot ventilate (CICV)’ scenario. Although surgical…”
    Get full text
    Journal Article
  9. 9
  10. 10

    The Airtraq® as a rescue airway device following failed direct laryngoscopy: a case series by Maharaj, C. H., Costello, J. F., McDonnell, J. G., Harte, B. H., Laffey, J. G.

    Published in Anaesthesia (01-06-2007)
    “…Summary We report the successful use of the Airtraq® as a rescue device following failed direct laryngoscopy, in patients deemed at increased risk for…”
    Get full text
    Journal Article
  11. 11

    Learning and performance of tracheal intubation by novice personnel: a comparison of the Airtraq® and Macintosh laryngoscope by Maharaj, C. H., Costello, J. F., Higgins, B. D., Harte, B. H., Laffey, J. G.

    Published in Anaesthesia (01-07-2006)
    “…Summary Direct laryngoscopic tracheal intubation is taught to many healthcare professionals as it is a potentially lifesaving procedure. However, it is a…”
    Get full text
    Journal Article
  12. 12

    Tracheal intubation in patients with cervical spine immobilization: a comparison of the Airwayscope®, LMA CTrach®, and the Macintosh laryngoscopes by Malik, M.A., Subramaniam, R., Churasia, S., Maharaj, C.H., Harte, B.H., Laffey, J.G.

    Published in British journal of anaesthesia : BJA (01-05-2009)
    “…The purpose of this study was to evaluate the effectiveness of the Pentax AWS®, and the LMA CTrach®, in comparison with the Macintosh laryngoscope, when…”
    Get full text
    Journal Article
  13. 13

    Determination of the optimal stylet strategy for the C‐MAC® videolaryngoscope by McElwain, J., Malik, M. A., Harte, B. H., Flynn, N. H., Laffey, J. G.

    Published in Anaesthesia (01-04-2010)
    “…Summary The C‐MAC® videolaryngoscope is a novel intubation device that incorporates a camera system at the end of its blade, thereby facilitating obtaining a…”
    Get full text
    Journal Article
  14. 14

    A comparison of direct and indirect laryngoscopes and the ILMA in novice users: a manikin study by Maharaj, C. H., McDonnell, J. G., Harte, B. H., Laffey, J. G.

    Published in Anaesthesia (01-11-2007)
    “…Summary Direct laryngoscopic tracheal intubation using the Macintosh laryngoscope is taught to many healthcare professionals as it is a potentially life‐saving…”
    Get full text
    Journal Article
  15. 15

    Retention of tracheal intubation skills by novice personnel: a comparison of the Airtraq® and Macintosh laryngoscopes by Maharaj, C. H., Costello, J., Higgins, B. D., Harte, B. H., Laffey, J. G.

    Published in Anaesthesia (01-03-2007)
    “…Summary Direct laryngoscopic tracheal intubation is a potentially lifesaving manoeuvre, but it is a difficult skill to acquire and to maintain. These…”
    Get full text
    Journal Article
  16. 16

    The effect of high‐flow nasal oxygen flow rate on gas exchange in apnoeic patients: a randomised controlled trial by Lyons, C., McElwain, J., Young, O., O'Gorman, D. A., Harte, B. H., Kinirons, B., Grady, D., Laffey, J. G., Callaghan, M.

    Published in Anaesthesia (01-06-2024)
    “…Summary High‐flow nasal oxygen can be administered at induction of anaesthesia for the purposes of pre‐oxygenation and apnoeic oxygenation. This intervention…”
    Get full text
    Journal Article
  17. 17

    Pre‐oxygenation with facemask oxygen vs high‐flow nasal oxygen vs high‐flow nasal oxygen plus mouthpiece: a randomised controlled trial by Lyons, C., McElwain, J., Coughlan, M. G., O’Gorman, D. A., Harte, B. H., Kinirons, B., Laffey, J. G., Callaghan, M.

    Published in Anaesthesia (01-01-2022)
    “…Summary High‐flow nasal oxygen used before and during apnoea prolongs time to desaturation at induction of anaesthesia. It is unclear how much oxygenation…”
    Get full text
    Journal Article
  18. 18

    Recovery of older patients undergoing ambulatory anaesthesia with isoflurane or sevoflurane by Mahajan, V. A., Ni Chonghaile, M., Bokhari, S. A., Harte, B. H., Flynn, N. M., Laffey, J. G.

    Published in European journal of anaesthesiology (01-06-2007)
    “…BACKGROUND:Delayed recovery of cognitive function is a well-recognized phenomenon in older patients. The potential for the volatile anaesthetic used to…”
    Get full text
    Journal Article
  19. 19
  20. 20