Search Results - "Haninger, T."

  • Showing 1 - 18 results of 18
Refine Results
  1. 1

    DOSIMETRIC PROPERTIES OF THE NEW TLD ALBEDO NEUTRON DOSEMETER AWST-TL-GD 04 by Haninger, T, Henniger, J

    Published in Radiation protection dosimetry (01-09-2016)
    “…A new official albedo dosemeter based on thermoluminescent detectors has been introduced in 2015 by the individual monitoring service of the Helmholtz Zentrum…”
    Get full text
    Journal Article
  2. 2

    New eye lens dosemeters for integration in radiation protection glasses by Hoedlmoser, H., Greiter, M., Bandalo, V., Mende, E., Brönner, J., Kleinau, P., Haninger, T., Furlan, M., Schmid, M., Esser, R., Scheubert, P., Figel, M.

    Published in Radiation measurements (01-06-2019)
    “…With the annual dose limit for the lens of the eye being lowered to 20 mSv from 2019, both new efforts to improve radiation protection for this part of the…”
    Get full text
    Journal Article
  3. 3

    NEUTRON WORKPLACE SPECTROMETRY (ENERGY AND DIRECTION) USING TL DETECTORS: FIRST APPROACH AND RESPONSE FUNCTIONS by Radeck, D, Luszik-Bhadra, M, Haninger, T, Reginatto, M

    Published in Radiation protection dosimetry (01-08-2018)
    “…The response of albedo dosemeters depends on the energy and angle of the incident neutron radiation. For their use as personal dosemeters, a field-calibration…”
    Get full text
    Journal Article
  4. 4

    FIELD CALIBRATION OF A TLD ALBEDO DOSEMETER IN THE HIGH-ENERGY NEUTRON FIELD OF CERF by Haninger, T, Kleinau, P, Haninger, S

    Published in Radiation protection dosimetry (28-04-2017)
    “…The new albedo dosemeter-type AWST-TL-GD 04 has been calibrated in the CERF neutron field (Cern-EU high-energy Reference Field). This type of albedo dosemeter…”
    Get full text
    Journal Article
  5. 5

    PROPERTIES OF THE BEOSL DOSIMETRY SYSTEM IN THE FRAMEWORK OF A LARGE-SCALE PERSONAL MONITORING SERVICE by Haninger, T, Hödlmoser, H, Figel, M, König-Meier, D, Henniger, J, Sommer, M, Jahn, A, Ledtermann, G, Eßer, R

    Published in Radiation protection dosimetry (01-09-2016)
    “…The Individual Monitoring Service of the Helmholtz Zentrum München is currently using the BeOSL dosimetry system for monitoring ∼15 000 persons per month. This…”
    Get full text
    Journal Article
  6. 6

    Albedo neutron dosimetry in Germany: regulations and performance by Luszik-Bhadra, M, Zimbal, A, Busch, F, Eichelberger, A, Engelhardt, J, Figel, M, Frasch, G, Günther, K, Jordan, M, Martini, E, Haninger, T, Rimpler, A, Seifert, R

    Published in Radiation protection dosimetry (01-12-2014)
    “…Personal neutron dosimetry has been performed in Germany using albedo dosemeters for >20 y. This paper describes the main principles, the national standards,…”
    Get full text
    Journal Article
  7. 7

    Neutron dosimetry with TL albedo dosemeters at high energy accelerators by Haninger, T., Fehrenbacher, G.

    Published in Radiation protection dosimetry (01-01-2007)
    “…The GSF—Personal Monitoring Service uses the TLD albedo dosemeter as standard neutron personal dosemeter. Due to its low sensitivity for fast neutrons however,…”
    Get full text
    Journal Article
  8. 8

    Individual monitoring with BeOSL dosemeters: New dosemeters for extremity and area dosimetry by Hoedlmoser, H., Greiter, M., Bandalo, V., Brönner, J., Kleinau, P., Haninger, T., Mende, E., Emmerl, M., Scheubert, P., Esser, R., Figel, M.

    Published in Radiation measurements (01-03-2020)
    “…To extend the applications of BeOSL technology beyond whole body dosimetry, three new dosemeters were developed: an eye lens dosemeter and a finger ring…”
    Get full text
    Journal Article
  9. 9

    A BeOSL finger ring dosemeter by Hoedlmoser, H., Greiter, M., Bandalo, V., Brönner, J., Kleinau, P., Haninger, T., Emmerl, M., Mende, E., Scheubert, P., Esser, R., Figel, M.

    Published in Radiation measurements (01-02-2020)
    “…The Individual Monitoring Service (IMS) at the Helmholtz Zentrum München together with Dosimetrics GmbH has developed and characterized a new ring dosemeter…”
    Get full text
    Journal Article
  10. 10

    Estimation of human exposure to natural radionuclides by using in vivo skull measurements by Muikku, M., Rahola, T., Pusa, S., Salonen, L., Wahl, W., Roth, P., Haninger, T., Kucheida, D.

    Published in Radiation protection dosimetry (01-01-2003)
    “…In a preliminary study, in vivo skull measurements and in vitro urine measurements of 210Pb and natU have been performed to find out the individual, chronic…”
    Get full text
    Journal Article Conference Proceeding
  11. 11

    Performance of the BeOSL eye lens dosemeter with radiation protection glasses by Bandalo, V., Figel, M., Greiter, M.B., Brönner, J., Kleinau, P., Haninger, T., Strobel, I., Mende, E., Scheubert, P., Eßer, R., Furlan, M., Schmid, M., Hoedlmoser, H.

    Published in Radiation measurements (01-02-2020)
    “…A new BeOSL eye lens dosemeter for integration in radiation protection glasses has been investigated in laboratory tests on an Alderson head phantom. Several…”
    Get full text
    Journal Article
  12. 12

    Indoor Air as an Important Source for 210Pb Accumulation in Man by Haninger, T., Winkler, R., Roth, P., Trautmannsheimer, M., Wahl, W.

    Published in Radiation protection dosimetry (01-02-2000)
    “…A pilot study was performed with measurements in a German, inhabited, two-family house, to obtain data on the correlation between the equilibrium equivalent…”
    Get full text
    Journal Article
  13. 13

    In vivo measurements on the human skull for retrospective assessment of individual intakes of natural radionuclides by Haninger, T, Wahl, W, Salonen, L, Rahola, T, Kucheida, D, Roth, P

    Published in International Congress series (01-02-2002)
    “…In vivo skull measurements of Pb-210 have been performed to assess the individual, chronic intakes of natural radionuclides of five members of a family (two…”
    Get full text
    Journal Article
  14. 14
  15. 15
  16. 16
  17. 17

    Fission of heavy nuclei induced by stopped antiprotons. I. Inclusive characteristics of fission fragments by Hofmann, P, Iljinov, AS, Kim, YS, Mebel, MV, Daniel, H, David, P, von Egidy T, Haninger, T, Hartmann, FJ, Jastrzebski, J, Kurcewicz, W, Lieb, J, Machner, H, Plendl, HS, Riepe, G, Wright, B, Ziock, K

    Published in Physical review. C, Nuclear physics (01-05-1994)
    “…Antiproton-induced fission has been investigated with a novel double-arm fission fragment spectrometer. Inclusive distributions of total mass, individual mass,…”
    Get full text
    Journal Article
  18. 18

    Indoor Air as an Important Source for super(210)Pb Accumulation in Man by Haninger, T, Winkler, R, Roth, P, Trautmannsheimer, M, Wahl, W

    Published in Radiation protection dosimetry (01-01-2000)
    “…Aerosol samples collected in German two-family houses under low ventilation conditions were analyzed to define a correlation between the equilibrium equivalent…”
    Get full text
    Journal Article