Search Results - "Hanagaki, K"
-
1
Electron identification in Belle
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-06-2002)“…We report on electron identification methods and their performance in the Belle experiment at the KEK-B asymmetric B-Factory e +e − storage ring. Electrons are…”
Get full text
Journal Article -
2
Development of n+-in-p large-area silicon microstrip sensors for very high radiation environments – ATLAS12 design and initial results
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-11-2014)“…We have been developing a novel radiation-tolerant n+-in-p silicon microstrip sensor for very high radiation environments, aiming for application in the high…”
Get full text
Journal Article -
3
Charge collection and field profile studies of heavily irradiated strip sensors for the ATLAS inner tracker upgrade
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-09-2016)“…The ATLAS group has evaluated the charge collection in silicon microstrip sensors irradiated up to a fluence of 1×1016neq/cm2, exceeding the maximum of…”
Get full text
Journal Article -
4
Evaluation of test structures for the novel n+-in-p pixel and strip sensors for very high radiation environments
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-12-2013)“…Radiation-tolerant n+-in-p silicon sensors were developed for use in very high radiation environments. Novel n+-in-p silicon strip and pixel sensors and test…”
Get full text
Journal Article -
5
Detailed studies of full-size ATLAS12 sensors
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-09-2016)“…The “ATLAS ITk Strip Sensor Collaboration” R&D group has developed a second iteration of single-sided n+-in-p type micro-strip sensors for use in the tracker…”
Get full text
Journal Article -
6
Layer 0 in D0 silicon tracker for Run2b
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-09-2003)“…We report on the status of R&D of the innermost layer of the D0 Silicon Tracker for Run2b. Because of space constraints, the cooling issues, and the amount of…”
Get full text
Journal Article -
7
Study of surface properties of ATLAS12 strip sensors and their radiation resistance
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-09-2016)“…A radiation hard n+-in-p micro-strip sensor for the use in the Upgrade of the strip tracker of the ATLAS experiment at the High Luminosity Large Hadron…”
Get full text
Journal Article -
8
Lessons learned from the DØ Silicon Microstrip Tracker
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-04-2005)“…A Silicon Microstrip Tracker has been built and installed into the upgraded DØ detector for Run II at the Tevatron. It provides excellent b-hadron…”
Get full text
Journal Article -
9
Development of readout system for FE-I4 pixel module using SiTCP
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-12-2013)“…The ATLAS pixel detector will be replaced in the future High Luminosity-Large Hadron Collider (HL-LHC) upgrade to preserve or improve the detector performance…”
Get full text
Journal Article -
10
Evaluation of the performance of irradiated silicon strip sensors for the forward detector of the ATLAS Inner Tracker Upgrade
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-09-2016)“…The upgrade to the High-Luminosity LHC foreseen in about ten years represents a great challenge for the ATLAS inner tracker and the silicon strip sensors in…”
Get full text
Journal Article -
11
Design of an upgraded DØ silicon microstrip tracker for Run IIb at the tevatron
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-09-2004)“…The DØ collaboration planned to upgrade the Silicon Tracker to withstand the radiation dose corresponding to above 2 fb −1 of data. This new detector was…”
Get full text
Journal Article -
12
Evaluation of slim-edge, multi-guard, and punch-through-protection structures before and after proton irradiation
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-01-2013)“…Planar geometry silicon pixel and strip sensors for the high luminosity upgrade of the LHC (HL-LHC) require a high bias voltage of 1000V in order to withstand…”
Get full text
Journal Article -
13
Embedded pitch adapters: A high-yield interconnection solution for strip sensors
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-09-2016)“…A proposal to fabricate large area strip sensors with integrated, or embedded, pitch adapters is presented for the End-cap part of the Inner Tracker in the…”
Get full text
Journal Article -
14
Noise evaluation of silicon strip super-module with ABCN250 readout chips for the ATLAS detector upgrade at the High Luminosity LHC
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-09-2016)“…Toward High Luminosity LHC (HL-LHC), the whole ATLAS inner tracker will be replaced, including the semiconductor tracker (SCT) which is the silicon micro strip…”
Get full text
Journal Article -
15
A measurement of the branching fraction for the inclusive B→ Xsγ decays with the Belle detector
Published in Physics letters. B (05-07-2001)“…We have measured the branching fraction of the inclusive radiative B meson decay B→ X s γ to be Br( B→ X s γ)=(3.36±0.53(stat)±0.42(sys) +0.50 −0.54(th))×10…”
Get full text
Journal Article -
16
Electrical performance of a silicon micro-strip super-module prototype for the High-Luminosity LHC collider
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-01-2013)“…A major luminosity upgrade for the Large Hadron Collider (LHC) proton–proton collider at CERN is planned for ∼2022 to allow for peak luminosities of…”
Get full text
Journal Article -
17
Development of a silicon-microstrip super module prototype for the high luminosity LHC
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-01-2013)“…Following the Phase II upgrade of the CERN Large Hadron Collider (LHC) currently foreseen in 2022–2023, the High Luminosity LHC (HL-LHC) is expected to deliver…”
Get full text
Journal Article -
18
Development of novel n+-in-p Silicon Planar Pixel Sensors for HL-LHC
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-01-2013)“…We have been developing highly radiation-tolerant n+-in-p planar pixel sensors for use in the high-luminosity LHC. Novel n+-in-p structures were made using…”
Get full text
Journal Article -
19
Test beam evaluation of newly developed n-in-p planar pixel sensors for use in a high radiation environment
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-09-2016)“…Radiation-tolerant n-in-p planar pixel sensors have been under development in cooperation with Hamamatsu Photonics K.K. (HPK). This is geared towards…”
Get full text
Journal Article -
20
Evaluation of KEK n-in-p planar pixel sensor structures for very high radiation environments with testbeam
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-11-2014)“…Various structures for n-in-p planar pixel sensors have been developed at KEK in order to cope with the huge particle fluence in the upcoming LHC upgrades…”
Get full text
Journal Article