Search Results - "Hamada, Margarida Mizue"
-
1
Radiation damage studies on the optical and mechanical properties of plastic scintillators
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-02-1999)“…This paper describes the radiation damage studies on a large volume plastic scintillator based in polystyrene doped with PPO and POPOP. The consequences on…”
Get full text
Journal Article -
2
Influence of Impurities on the Radiation Response of the TlBr Semiconductor Crystal
Published in Advances in materials science and engineering (01-01-2017)“…Two commercially available TlBr salts were used as the raw material for crystal growths to be used as radiation detectors. Previously, TlBr salts were purified…”
Get full text
Journal Article -
3
Temperature Dependence in the Long-Term Stability of the TlBr Detector
Published in IEEE transactions on nuclear science (01-08-2009)“…In this paper, TlBr detectors with three-electrodes were prepared and their long term stability evaluated as a function of the temperature. Systematic…”
Get full text
Journal Article -
4
Zonal Refining and Bridgman Technique for CsI:Tl Scintillation Crystal Growth
Published in Brazilian Journal of Radiation Sciences (04-12-2022)“…This work describes the development of the production of the crystal cesium iodide doped with thallium [CsI :Tl] for use as a radiation detector. For salt…”
Get full text
Journal Article -
5
Development and characterization of CsI(Tl) crystal for use as a radiation detector
Published in Brazilian Journal of Radiation Sciences (30-04-2021)“…Cesium iodide crystal activated with thallium (CsI(Tl)) is used as radiation sensor because of its favorable characteristics as scintillator, when excited by…”
Get full text
Journal Article -
6
Study of the petrology of the shale rock from the Parana basin
Published in Brazilian Journal of Radiation Sciences (30-04-2021)“…In the present work, the characteristics of the shale rock, collected in the surrounds of Limeira, in the interior of São Paulo, were studied. Shales are…”
Get full text
Journal Article -
7
Performance of the X-ray powder diffraction (XRD), X-ray fluorescence (XRF) and the industrial computed tomography used for characterization of the vesicular volcanic rock
Published in Brazilian Journal of Radiation Sciences (30-04-2021)“…Volcanic rock is a designation in geology given to extrusive igneous rocks. One type of igneous rock of interest, in economic terms, is vesicular, since,…”
Get full text
Journal Article -
8
Characterization of the petrology of the tar sandstone rock of the Paraná basin
Published in Brazilian Journal of Radiation Sciences (30-04-2021)“…In the state of São Paulo (Brazil), occurrences of tar sandstone are known in Botucatu, Angatuba, Pirambóia, Anhembi and Bofete municipalities. In the present…”
Get full text
Journal Article -
9
CHEMICAL AND PHYSICAL ANALYSIS OF SANDSTONE ROCK FROM BOTUCATU FORMATION
Published in Brazilian Journal of Radiation Sciences (30-04-2021)“…The productive capacity of the Guarani Aquifer System is subject to variations along its length, due to its complex structural and compositional heterogeneity…”
Get full text
Journal Article -
10
EVALUATION OF ITERATIVE ALGORITHMS FOR TOMOGRAPHY IMAGE RECONSTRUCTION
Published in Brazilian Journal of Radiation Sciences (19-02-2019)“…The greatest impact of the tomography technology currently occurs in medicine. The success is due to the fact that human body presents standardized dimensions…”
Get full text
Journal Article -
11
IMAGE QUALITY ANALYSIS OF AN INDUSTRIAL INSTANT NON-SCANNING TOMOGRAPHY SYSTEM WITH DIFFERENT COLLIMATORS
Published in Brazilian Journal of Radiation Sciences (06-02-2019)“…The greatest impact of the computed tomography (CT) applications currently occurs in medicine. In industry there is much interest of using CT in order to know…”
Get full text
Journal Article -
12
GALLIUM-67 CITRATE USED AS A TRACER OF ACETONE PRODUCTION ROUTE
Published in Brazilian Journal of Radiation Sciences (06-02-2019)“…In this work the pathway of the chemical product and the kinetics parameters were evaluated in a laboratory plant settled, using 0.4 GBq (10 mL) of 67Ga…”
Get full text
Journal Article -
13
Gas–liquid distribution in a bubble column using industrial gamma-ray computed tomography
Published in Radiation physics and chemistry (Oxford, England : 1993) (01-02-2014)“…A gas absorption column used as a simulator bubble column for industrial processes was evaluated, using the third-generation industrial computed tomography…”
Get full text
Journal Article -
14
The effect of Pb 2+ dopant in the crystal of CsI and its application as scintillation detector: a study of alpha particles
Published in Radiation effects and defects in solids (01-12-2012)Get full text
Journal Article -
15
The effect of Pb^sup 2+^ dopant in the crystal of CsI and its application as scintillation detector: a study of alpha particles
Published in Radiation effects and defects in solids (01-12-2012)“…Scintillation crystals have been used in various fields, such as high energy physics, nuclear instrumentation, radiation measurements, medical imaging, nuclear…”
Get full text
Journal Article -
16
The effect of Pb2+ dopant in the crystal of CsI and its application as scintillation detector: a study of alpha particles
Published in Radiation effects and defects in solids (01-12-2012)“…Scintillation crystals have been used in various fields, such as high energy physics, nuclear instrumentation, radiation measurements, medical imaging, nuclear…”
Get full text
Journal Article -
17
Luminescence and scintillation characteristics in the CsI:Br crystal on Br concentrations
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-01-2005)“…Cesium Iodide (CsI) doped with Cesium Bromide (CsBr) was grown, using the Bridgman technique, varying the concentration of the Br from 10−2 to 2×10−1 mol. The…”
Get full text
Journal Article -
18
Target theory applied in the radiation damage analysis for organic detectors
Published in 2007 IEEE Nuclear Science Symposium Conference Record (01-10-2007)“…The target theory was used to explain the radiation damage in samples containing 1% (g//L) of 2,5- diphenil-oxazolyl (PPO) diluted in toluene and irradiated…”
Get full text
Conference Proceeding -
19
Development of a Monte Carlo simulation to study linear radiation position sensitive detectors
Published in 2007 IEEE Nuclear Science Symposium Conference Record (01-10-2007)“…This work describes a special Monte Carlo program proposed to study the extension of light generation in a bar of plastic scintillator used as a linear…”
Get full text
Conference Proceeding -
20
Development of neutron detector using the surface barrier sensor with polyethylene (n, p) and 10B (n,α) converters
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-02-2001)“…A Si semiconductor detector, surface barrier type, with a slim film of a converter material, capable to produce charged particles, was used as a sensor of…”
Get full text
Journal Article