Search Results - "HOGAN, G. E"
-
1
Measurements of ultracold-neutron lifetimes in solid deuterium
Published in Physical review letters (30-12-2002)“…We present the first measurements of the survival time of ultracold neutrons (UCNs) in solid deuterium (SD2). This critical parameter provides a fundamental…”
Get full text
Journal Article -
2
Postnatal ventilatory response to CO2 in awake piglets
Published in Respiratory physiology & neurobiology (31-01-2011)“…Abstract Abnormal ventilatory responses to increased levels of inspired CO2 during postnatal development may pose a risk for Sudden Infant Death Syndrome,…”
Get full text
Journal Article -
3
Determination of the axial-vector weak coupling constant with ultracold neutrons
Published in Physical review letters (29-10-2010)“…A precise measurement of the neutron decay β asymmetry A₀ has been carried out using polarized ultracold neutrons from the pulsed spallation ultracold neutron…”
Get full text
Journal Article -
4
Do genes on rat chromosomes 9, 13, 16, 18, and 20 contribute to regulation of breathing?
Published in Respiratory physiology & neurobiology (30-05-2003)“…As part of a large scale, high through-put physiologic genomics study, we sought to determine whether genes on rat chromosomes 9, 13, 16, 18, and 20 contribute…”
Get full text
Journal Article -
5
Image reconstruction and material Z discrimination via cosmic ray muon radiography
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-03-2004)“…Highly penetrating cosmic ray muons shower the Earth at the rate of 10,000 m −2 min −1 at sea level. In our previous work (Nature 422 (2003) 277; Rev. Sci…”
Get full text
Journal Article -
6
Tomographic Imaging with Cosmic Ray Muons
Published in Science & global security (15-10-2008)“…Over 120 million vehicles enter the United States each year. Many are capable of transporting hidden nuclear weapons or nuclear material. Currently deployed…”
Get full text
Journal Article -
7
New Limit for the Lepton-Family-Number Nonconserving Decay μ + → e + γ
Published in Physical review letters (23-08-1999)Get full text
Journal Article -
8
Development of multiframe detectors for ultrafast radiography with 800 MeV protons
Published in IEEE transactions on nuclear science (01-02-2002)“…We constructed two small-area pixelated detectors, which can record signals produced by 800-MeV proton beam micropulses with a repetition rate of 358 ns. The…”
Get full text
Journal Article -
9
Demonstration of a solid deuterium source of ultra-cold neutrons
Published in Physics letters. B (22-07-2004)“…Ultra-cold neutrons (UCN), neutrons with energies low enough to be confined by the Fermi potential in material bottles, are playing an increasing role in…”
Get full text
Journal Article -
10
First measurement of the neutron beta asymmetry with ultracold neutrons
Published in Physical review letters (09-01-2009)“…We report the first measurement of an angular correlation parameter in neutron beta decay using polarized ultracold neutrons (UCN). We utilize UCN with…”
Get full text
Journal Article -
11
An 800-MeV proton radiography facility for dynamic experiments
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (03-11-1999)“…The capability has successfully been developed at the Los Alamos Nuclear Science Center (LANSCE) to utilize a spatially and temporally prepared 800 MeV proton…”
Get full text
Journal Article -
12
Sealed drift tube cosmic ray veto counters
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-05-2011)“…We describe a simple drift tube counter that has been used as a cosmic ray veto for the UCNA experiment, a first-ever measurement of the neutron beta-asymmetry…”
Get full text
Journal Article -
13
A narrow-gap ion chamber for beam motion correction in proton radiography experiments
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-08-2003)“…A small gap, segmented hydrogen ion chamber was constructed for beam position monitoring in dynamic proton radiography imaging experiments at the Los Alamos…”
Get full text
Journal Article -
14
Determination of the Pion Structure Function from Muon-Pair Production
Published in Physical review letters (09-04-1979)Get full text
Journal Article -
15
Evidence for Longitudinal Photon Polarization in Muon-Pair Production by Pions
Published in Physical review letters (22-10-1979)Get full text
Journal Article -
16
New Measurement of the Rate for Pion Beta Decay
Published in Physical review letters (25-07-1983)Get full text
Journal Article -
17
Construction and performance of MEGAs low-mass, high-rate cylindrical MWPCs
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-11-1998)“…A design for extremely low mass, high-resolution multiwire proportional chambers (MWPC) was achieved by the MEGA collaboration in its experiment to search for…”
Get full text
Journal Article -
18
Determination of the Axial-Vector Weak Coupling Constant with Ultracold Neutrons
Published 25-09-2010“…Phys.Rev.Lett.105:181803,2010 A precise measurement of the neutron decay $\beta$-asymmetry $A_0$ has been carried out using polarized ultracold neutrons (UCN)…”
Get full text
Journal Article -
19
Inexpensive and practical sealed drift-tube neutron detector
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-07-2009)“…The design, construction, and performance of a type of sealed 3He drift tubes for neutron detection are presented. Because the 3He pressure is in the 25–300…”
Get full text
Journal Article -
20
Search for spontaneous conversion of muonium to antimuonium
Published in Physical review. D, Particles and fields (01-09-1993)“…An experimental search for the spontaneous conversion of muonium to antimuonium is described. A 10 MeV/[ital c] [mu][sup +] beam of average intensity…”
Get full text
Journal Article