Search Results - "HIRSCHORN, D"

  • Showing 1 - 9 results of 9
Refine Results
  1. 1

    Wavelet transform-based image compression for transmission of MR data [published erratum appears in AJR Am J Roentgenol 1997 Sep;169(3):919] by Maldjian, JA, Liu, WC, Hirschorn, D, Murthy, R, Semanczuk, W

    Published in American journal of roentgenology (1976) (01-07-1997)
    “…The purpose of this study was to develop an effective, inexpensive teleradiology image-transmission system for transfer of MR studies using wavelet transform…”
    Get full text
    Journal Article Conference Proceeding
  2. 2

    Impact of a diagnostic workstation on workflow in the emergency department at a level I trauma center by Hirschorn, D S, Hinrichs, C R, Gor, D M, Shah, K, Visvikis, G

    Published in J DIGITAL IMAGING (01-06-2001)
    “…When a computed tomography (CT) scan on a patient from the emergency department is completed at University of Medicine and Dentistry of New Jersey…”
    Get full text
    Journal Article Conference Proceeding
  3. 3
  4. 4

    Starting to think digitally: evaluation of web browser-based presentation of images at a Rad Path conference in a traditional film-based environment by Hirschorn, D S, Sider, L F

    Published in Journal of digital imaging (01-05-2000)
    “…Images have traditionally been projected from film to a large-screen television at the weekly Rad Path conference at University of Medicine and Dentistry of…”
    Get full text
    Journal Article
  5. 5

    Intraoperative functional MRI using a real-time neurosurgical navigation system by MALDJIAN, J. A, SCHULDER, M, LIU, W.-C, MUN, I.-K, HIRSCHORN, D, MURTHY, R, CARMEL, P, KALNIN, A

    Published in Journal of computer assisted tomography (01-11-1997)
    “…A 42-year-old-man had focal left hand motor seizures. MR studies demonstrated a right posterior frontal brain tumor. Functional MRI was performed, localizing…”
    Get full text
    Journal Article
  6. 6

    Agonist anti-GITR antibody induces CD8 T cell-mediated tumor rejection by Cohen, A. D., Diab, A., Perales, M. A., Duan, F., Jenq, R., Rizzuto, G., Hirschorn-Cymmerman, D., Merghoub, T., Wolchok, J. D., Houghton, A. N.

    Published in Journal of clinical oncology (20-06-2007)
    “…Abstract only 3058 Background: Signaling through GITR (glucocorticoid-induced tumor necrosis factor receptor) can abrogate the suppressive effects of…”
    Get full text
    Journal Article
  7. 7

    Distributed time-constant impedance responses interpreted in terms of physically meaningful properties by Hirschorn, Bryan D

    Published 01-01-2010
    “…Models invoking Constant-Phase Elements (CPE) are often used to fit impedance data arising from a broad range of experimental systems. The physical origins of…”
    Get full text
    Dissertation
  8. 8

    Distributed time-constant impedance responses interpreted in terms of physically meaningful properties by Hirschorn, Bryan D

    “…Models invoking Constant-Phase Elements (CPE) are often used to fit impedance data arising from a broad range of experimental systems. The physical origins of…”
    Get full text
    Dissertation
  9. 9

    Scanning-tunneling-microscopy studies of disilane adsorption and pyrolytic growth on Si(100)-(2x1) by LIN, D.-S, HIRSCHORN, D.-S, CHIANG, T.-C, TSU, R, LUBBEN, D, GREENE, J. E

    Published in Physical review. B, Condensed matter (15-02-1992)
    “…Scanning tunneling microscopy has been employed to study the adsorption of disilane (Si{sub 2}H{sub 6}) and pyrolytic growth on Si(100)-(2{times}1) at various…”
    Get full text
    Journal Article