Search Results - "Högel, F."

  • Showing 1 - 14 results of 14
Refine Results
  1. 1

    A biomechanical evaluation of orthopaedic implants for hip fractures by finite element analysis and in-vitro tests by Eberle, S, Gerber, C, von Oldenburg, G, Högel, F, Augat, P

    “…The aim of this study was to test the hypothesis that a reinforced gamma nail for the fixation of subtrochanteric fractures would experience less stress during…”
    Get more information
    Journal Article
  2. 2

    Development of heterotopic ossifications, blood markers and outcome after radiation therapy in spinal cord injured patients by Krauss, H, Maier, D, Bühren, V, Högel, F

    Published in Spinal cord (01-05-2015)
    “…Study Design: Retrospective study. Objectives: This study was implemented to detect risk factors for the developing of heterotopic ossifications (HOs) in…”
    Get full text
    Journal Article
  3. 3

    Functional outcome of patients 12 and 48 weeks after acute traumatic tetraplegia and paraplegia: data analysis from 2004–2009 by Högel, F, Mach, O, Maier, D

    Published in Spinal cord (01-07-2012)
    “…Objectives: During the first rehabilitation of patients with traumatic spinal cord injuries (SCIs), professional skills are learned, which can be objectified…”
    Get full text
    Journal Article
  4. 4

    Bone healing of critical size defects of the rat femur after the application of bone marrow aspirate and two different rh-BMP7 concentrations by Högel, F., Hoffmann, S., Hungerer, S., Fleischacker, E., Ullamann, T., Betz, O. B., Augat, P.

    “…Background It is known that the application of growth factors can enhance fracture healing in defect fractures. The role of bone marrow aspirate (BMA) in…”
    Get full text
    Journal Article
  5. 5

    Reamed intramedullary nailing of diaphyseal tibial fractures: comparison of compression and non-compression nailing by Högel, F., Gerber, C., Bühren, V., Augat, P.

    “…Background Modern intramedullary implants provide the option to perform compression at the fracture gap in long bone fractures via a compression screw…”
    Get full text
    Journal Article
  6. 6

    Fracture healing after reamed and unreamed intramedullary nailing in sheep tibia by Högel, F, Schlegel, U, Südkamp, N, Müller, C

    Published in Injury (01-07-2011)
    “…Abstract Intramedullary nailing is a well-established method for stabilisation of long-bone shaft fractures. It is still a controversy as to whether the…”
    Get full text
    Journal Article
  7. 7

    Pulmonary fat embolism after reamed and unreamed nailing of femoral fractures by Högel, F, Gerlach, U.V, Südkamp, N.P, Müller, C.A

    Published in Injury (01-12-2010)
    “…Abstract Background To determine whether reamed or unreamed intramedullary nailing of femoral fractures results in higher incidence of pulmonary fat embolism,…”
    Get full text
    Journal Article
  8. 8

    Distal radius fracture fixation with volar locking plates and additional bone augmentation in osteoporotic bone: a biomechanical study in a cadaveric model by Högel, F., Mair, S., Eberle, S., Weninger, P., von Oldenburg, G., Augat, P.

    “…Background Fractures of the distal radius represent the most common fractures in adults. Volar locked plating has become a popular method for treating these…”
    Get full text
    Journal Article
  9. 9

    Biomechanical comparison of two locking plate systems for the distal tibia by Högel, F., Hoffmann, S., Weninger, P., Bühren, V., Augat, P.

    “…Background Distal tibia fractures are known to be difficult to stabilize and nonunions often occur because of a relative instability of the fragments…”
    Get full text
    Journal Article
  10. 10

    Komplikationen des Segmenttransports: Regeneratinsuffizienzbehandlung mittels Wachstumsfaktoren by Wagner, F., Militz, M., Högel, F., Bühren, V., Hungerer, S.

    Published in Trauma und Berufskrankheit (01-06-2012)
    “…Zusammenfassung Der Segmenttransport zur Rekonstruktion von Röhrenknochendefekten >2 cm Länge ist ein sicheres Verfahren zur Wiederherstellung der anatomischen…”
    Get full text
    Journal Article
  11. 11

    Stability of volar fixed-angle plating for distal radius fractures. Failure modes in osteoporotic bone by Mair, S, Weninger, P, Högel, F, Panzer, S, Augat, P

    Published in Der Unfallchirurg (01-04-2013)
    “…Distal radius fractures continue to show significant complication rates after operative treatment with locked plating. Failure occurs by screw loosening or…”
    Get full text
    Journal Article
  12. 12

    Die Stabilität von distalen Radiusfrakturen mit volaren winkelstabilen Plattenosteosynthesen: Versagensmechanismen im osteoporotischen Knochen by Mair, S., Weninger, P., Högel, F., Panzer, S., Augat, P.

    Published in Der Unfallchirurg (01-04-2013)
    “…Zusammenfassung Hintergrund Die operative Behandlung von distalen Radiusfrakturen mit Plattenosteosynthesen kann zu Komplikationen in Form einer…”
    Get full text
    Journal Article
  13. 13

    Percutaneous administration of recombinant human bone morphogenetic protein-7 (rhBMP-7) after callus distraction. Two case reports by Högel, F, Militz, M, Bühren, V, Augat, P, Wagner, F

    Published in Der Unfallchirurg (01-02-2011)
    “…Two cases of increased bone density after callus distraction are described following percutaneous administration of 3.5 mg recombinant bone morphogenetic…”
    Get full text
    Journal Article
  14. 14

    Perkutane Applikation von rekombinantem humanem Bone Morphogenetic Protein-7 (rhBMP-7) nach Kallusdistraktion: Zwei Fallberichte by Högel, F., Militz, M., Bühren, V., Augat, P., Wagner, F.

    Published in Der Unfallchirurg (01-02-2011)
    “…Zusammenfassung In der vorliegenden Arbeit werden 2 Fälle von zunehmender Kallusdichte nach der perkutanen Applikation von 3,5 mg rekombinantem humanem Bone…”
    Get full text
    Journal Article