Search Results - "Gurbuz, Yasar"

Refine Results
  1. 1

    Graphene-interfaced electrical biosensor for label-free and sensitive detection of foodborne pathogenic E. coli O157:H7 by Pandey, Ashish, Gurbuz, Yasar, Ozguz, Volkan, Niazi, Javed H., Qureshi, Anjum

    Published in Biosensors & bioelectronics (15-05-2017)
    “…E. coli O157:H7 is an enterohemorrhagic bacteria responsible for serious foodborne outbreaks that causes diarrhoea, fever and vomiting in humans. Recent…”
    Get full text
    Journal Article
  2. 2

    Development of surface chemistry for surface plasmon resonance based sensors for the detection of proteins and DNA molecules by Altintas, Zeynep, Uludag, Yıldız, Gurbuz, Yasar, Tothill, Ibtisam

    Published in Analytica chimica acta (27-01-2012)
    “…The principle of applied protein and DNA assays on dendrimer modified MUDA-SAM. [Display omitted] ► Immobilisation of biomolecules to sensor surface is a…”
    Get full text
    Journal Article
  3. 3

    All-Pass Network and Transformer Based SiGe BiCMOS Phase Shifter for Multi-Band Arrays by Caliskan, Can, Yazici, Melik, Gurbuz, Yasar

    “…In this brief, an all-pass network (APN) based SiGe BiCMOS phase shifter (PS) is presented showing a root-mean-square (RMS) phase error lower than 5.6° for a…”
    Get full text
    Journal Article
  4. 4

    7-Bit SiGe-BiCMOS Step Attenuator for X-Band Phased-Array RADAR Applications by Davulcu, Murat, Caliskan, Can, Kalyoncu, Ilker, Kaynak, Mehmet, Gurbuz, Yasar

    “…This letter presents a 7-bit CMOS step attenuator for the first time in the literature, designed with isolated NMOS (iNMOS) using IHP 0.25 μm SiGe BiCMOS…”
    Get full text
    Journal Article
  5. 5

    A Phase-Calibration Method for Vector-Sum Phase Shifters Using a Self-Generated LUT by Kalyoncu, Ilker, Ozeren, Emre, Burak, Abdurrahman, Ceylan, Omer, Gurbuz, Yasar

    “…This paper presents a new self-calibration method for vector-sum phase shifters (PS) to compensate for process variations and achieve reconfigurable operating…”
    Get full text
    Journal Article
  6. 6

    Solution-Based PbS Photodiodes, Integrable on ROIC, for SWIR Detector Applications by Heves, Emre, Ozturk, Cem, Ozguz, Volkan, Gurbuz, Yasar

    Published in IEEE electron device letters (01-05-2013)
    “…Photodiodes, based on PbS colloidal quantum dots (CQD), are realized on both silicon substrates and the replicas of the read-out integrated circuits (ROICs) to…”
    Get full text
    Journal Article
  7. 7

    A 26-GHz Vector Modulator in 130-nm SiGe BiCMOS Achieving Monotonic 10-b Phase Resolution Without Calibration by Kalyoncu, Ilker, Burak, Abdurrahman, Kaynak, Mehmet, Gurbuz, Yasar

    “…This paper presents a high-resolution (10-b) vevtor-modulator (VM) phase shifter (PS) in 130-nm SiGe BiCMOS targeting 5G applications at 26 GHz. It employs a…”
    Get full text
    Conference Proceeding
  8. 8

    An aptamer based competition assay for protein detection using CNT activated gold-interdigitated capacitor arrays by Qureshi, Anjum, Roci, Irena, Gurbuz, Yasar, Niazi, Javed H.

    Published in Biosensors & bioelectronics (15-04-2012)
    “…► The aptamer can competitively bind its target protein or a complementary strand (cRNA) in co-mixtures. ► An RNA aptamer wrapped CNT activated capacitor array…”
    Get full text
    Journal Article
  9. 9

    A novel interdigitated capacitor based biosensor for detection of cardiovascular risk marker by Quershi, Anjum, Gurbuz, Yasar, Kang, Weng P., Davidson, Jimmy L.

    Published in Biosensors & bioelectronics (15-12-2009)
    “…C-reactive protein (CRP) is a potential biomarker whose elevated levels in humans determine cardiovascular disease risk and inflammation. In this study, we…”
    Get full text
    Journal Article
  10. 10

    A single-chip RF power amplifier with integrated impedance matching Wilkinson power dividers for 5.2 GHz WLAN applications by Kaymaksut, Ercan, Gürbüz, Yasar, Tekin, İbrahim

    Published in Microwave and optical technology letters (01-11-2010)
    “…In this article, a new on‐chip power combining technique by using impedance matching Wilkinson power divider circuits will be presented. Two impedance matching…”
    Get full text
    Journal Article
  11. 11

    Impedance matching Wilkinson power dividers in 0.35 μm SiGe BiCMOS technology by Kaymaksut, Ercan, Gürbüz, Yasar, Tekin, Ibrahim

    Published in Microwave and optical technology letters (01-03-2009)
    “…This article presents two miniature impedance matching Wilkinson power divider circuits in 0.35 μm SiGe BiCMOS technology for on‐chip power combining…”
    Get full text
    Journal Article
  12. 12

    A SiGe BiCMOS W-Band Single-Chip Frequency Extension Module for VNAs by Turkmen, Esref, Gurbuz, Yasar

    “…This article reports the design and characterization of a W-band frequency extension module, implemented in a 0.13-μm SiGe BiCMOS technology, for the vector…”
    Get full text
    Journal Article
  13. 13

    Biosensors for cardiac biomarkers detection: A review by Qureshi, Anjum, Gurbuz, Yasar, Niazi, Javed H.

    Published in Sensors and actuators. B, Chemical (01-08-2012)
    “…The cardiovascular disease (CVD) is considered as a major threat to global health. Therefore, there is a growing demand for a range of portable, rapid and low…”
    Get full text
    Journal Article
  14. 14

    Diamond microelectronic gas sensor for detection of benzene and toluene by Gurbuz, Yasar, Kang, Weng P, Davidson, Jimmy L, Kerns, David V

    Published in Sensors and actuators. B, Chemical (01-05-2004)
    “…We have applied diamond chemical sensor to detect benzene (C 6H 6) and toluene (C 7H 8), volatile organic compounds and possible indication of environmental…”
    Get full text
    Journal Article
  15. 15

    Label-free capacitance based aptasensor platform for the detection of HER2/ErbB2 cancer biomarker in serum by Qureshi, Anjum, Gurbuz, Yasar, Niazi, Javed H.

    Published in Sensors and actuators. B, Chemical (01-12-2015)
    “…•Label-free aptasensor platform for detecting cancer biomarker.•Change in capacitance as the ssDNA aptamer interacts with HER2 protein.•Capacitance change…”
    Get full text
    Journal Article
  16. 16

    Capacitive aptamer–antibody based sandwich assay for the detection of VEGF cancer biomarker in serum by Qureshi, Anjum, Gurbuz, Yasar, Niazi, Javed H.

    Published in Sensors and actuators. B, Chemical (31-03-2015)
    “…•Selected anti-VEGF aptamer that specifically bind VEGF protein, a cancer biomarker.•Fabricated an aptamer based biosensor comprised of gold IDE capacitor…”
    Get full text
    Journal Article
  17. 17

    A K-Band 5G Phased Array RX Channel With 3.3-dB NF and 28.5-dB Gain in 130-nm SiGe by Kalyoncu, Ilker, Burak, Abdurrahman, Gurbuz, Yasar

    “…This brief presents a low-noise K-band phased array receive channel implemented in a 130-nm SiGe BiCMOS process. The IC consists of a cascode LNA, a vector…”
    Get full text
    Journal Article
  18. 18

    A 6 Bit Vector-Sum Phase Shifter With a Decoder Based Control Circuit for X-Band Phased-Arrays by Cetindogan, Barbaros, Ozeren, Emre, Ustundag, Berktug, Kaynak, Mehmet, Gurbuz, Yasar

    “…This letter presents a 6 bit vector-sum phase shifter with a novel control circuitry for X-band phased-arrays using a 0.25 \mu m SiGe BiCMOS technology. A…”
    Get full text
    Journal Article
  19. 19

    A Low Noise Variable Gain Amplifier With Low Phase Error for X- and Ku-Band Phased Arrays by Altintas, Kutay, Ozkan, Tahsin Alper, Burak, Abdurrahman, Yazici, Melik, Gurbuz, Yasar

    “…In this article, we present a detailed analysis of current steering, wideband, low noise, variable gain amplifier (VGA) and a novel method to decrease its…”
    Get full text
    Journal Article
  20. 20

    A 7-Bit Reverse-Saturated SiGe HBT Discrete Gain Step Attenuator by Davulcu, Murat, Burak, Abdurrahman, Gurbuz, Yasar

    “…In this brief, the analysis, design, and measured results of a fully integrated 7-bit step attenuator implemented in a 0.25-μm Silicon-Germanium (SiGe) BiCMOS…”
    Get full text
    Journal Article