Search Results - "Guena, Jocelyne"

Refine Results
  1. 1

    New Measurement of the 1S-3S Transition Frequency of Hydrogen: Contribution to the Proton Charge Radius Puzzle by Fleurbaey, Hélène, Galtier, Sandrine, Thomas, Simon, Bonnaud, Marie, Julien, Lucile, Biraben, François, Nez, François, Abgrall, Michel, Guéna, Jocelyne

    Published in Physical review letters (04-05-2018)
    “…We present a new measurement of the 1S-3S two-photon transition frequency of hydrogen, realized with a continuous-wave excitation laser at 205 nm on a…”
    Get full text
    Journal Article
  2. 2

    Evaluation of Doppler shifts to improve the accuracy of primary atomic fountain clocks by Guéna, Jocelyne, Li, Ruoxin, Gibble, Kurt, Bize, Sébastien, Clairon, André

    Published in Physical review letters (01-04-2011)
    “…We demonstrate agreement between measurements and ab initio calculations of the frequency shifts caused by distributed cavity phase variations in the microwave…”
    Get full text
    Journal Article
  3. 3

    Progress in atomic fountains at LNE-SYRTE by Guena, J., Abgrall, M., Rovera, D., Laurent, P., Chupin, B., Lours, M., Santarelli, G., Rosenbusch, P., Tobar, M. E., Ruoxin Li, Gibble, K., Clairon, A., Bize, S.

    “…We give an overview of the work done with the Laboratoire National de Metrologie et d'Essais-Systemes de Reference Temps-Espace (LNE-SYRTE) fountain ensemble…”
    Get full text
    Journal Article Conference Proceeding
  4. 4

    Demonstration of a dual alkali Rb/Cs fountain clock by Guena, Jocelyne, Rosenbusch, Peter, Laurent, Philippe, Abgrall, Michel, Rovera, Daniele, Santarelli, Giorgio, Tobar, Michael E., Bize, Sebastien, Clairon, Andre

    “…We report the operation of a dual Rb/Cs atomic fountain clock. 133 Cs and 87 Rb atoms are cooled, launched, and detected simultaneously in LNE-SYRTE's FO2…”
    Get full text
    Journal Article Conference Proceeding
  5. 5

    High-Stability Comparison of Atomic Fountains Using Two Different Cryogenic Oscillators by Abgrall, M., Guena, J., Lours, M., Santarelli, G., Tobar, M. E., Bize, S., Grop, S., Dubois, B., Fluhr, C., Giordano, V.

    “…We present a detailed characterization of two atomic clock interrogation systems based on two different cryogenic sapphire oscillators operated simultaneously…”
    Get full text
    Journal Article
  6. 6

    Switching atomic fountain clock microwave interrogation signal and high-resolution phase measurements by Santarelli, G., Governatori, G., Chambon, D., Lours, M., Rosenbusch, P., Guena, J., Chapelet, F., Bize, S., Tobar, M., Laurent, P., Potier, T., Clairon, A.

    “…This paper focuses on the development of tools aiming to solve several problems related to the microwave interrogation signal in atomic fountains. We first…”
    Get full text
    Journal Article
  7. 7

    Carrier-phase two-way satellite frequency transfer between LNE-SYRTE and PTB by Fujieda, Miho, Takiguchi, Hiroshi, Achkar, Joseph, Abgrall, Michel, Guena, Jocelyne, Riedel, Franziska, Benkler, Erik, Weyers, Stefan, Piester, Dirk

    “…We performed a carrier-phase two-way satellite frequency transfer (TWCP) experiment between LNE-SYRTE and PTB for several days in September 2015. Different…”
    Get full text
    Conference Proceeding
  8. 8
  9. 9

    Ultralow noise microwave generation with fiber-based optical frequency comb and application to atomic fountain clock by Millo, J., Abgrall, M., Lours, M., English, E. M. L., Jiang, H., Guéna, J., Clairon, A., Tobar, M. E., Bize, S., Le Coq, Y., Santarelli, G.

    Published in Applied physics letters (06-04-2009)
    “…We demonstrate the use of a fiber-based femtosecond laser locked onto an ultrastable optical cavity to generate a low-noise microwave reference signal…”
    Get full text
    Journal Article
  10. 10

    A Neutral Atom Frequency Reference in the Deep Ultraviolet with FractionalUncertainty = 5.7×10-15 by Mcferran, John J., Yi, Lin, Mejri, Sinda, Di Manno, Sylvain, Zhang, Wei, Guéna, Jocelyne, Le Coq, Yann, Bize, Sébastien

    Published in Physical review letters (2012)
    “…We present an assessment of the (6s 2 ) S01(6s6p)P03 clock transition frequency in Hg199 with an uncertainty reduction of nearly 3 orders of magnitude and…”
    Get full text
    Journal Article
  11. 11

    Design Details of FOCS-2, an Improved Continuous Cesium Fountain Frequency Standard by Fuzesi, Ferenc, Plimmer, Mark D., Dudle, Gregor, Guena, Jocelyne, Thomann, Pierre

    “…We report on the design, construction and current status of FOCS-2, the second continuous fountain microwave cesium frequency standard after FOCS-1. Both…”
    Get full text
    Conference Proceeding
  12. 12

    Invited Review: Progress in atomic fountains at LNE-SYRTE by Guéna, Jocelyne, Abgrall, Michel, Rovera, Daniele, Laurent, Philippe, Chupin, Baptiste, Lours, Michel, Santarelli, Giorgio, Rosenbusch, Peter, Tobar, Michael E., Li, R., Gibble, Kurt, Clairon, André, Bize, Sébastien

    “…We give an overview of the work done with the Laboratoire National de Metrologie et d'Essais-Systemes de Reference Temps-Espace (LNE-SYRTE) fountain ensemble…”
    Get full text
    Journal Article
  13. 13

    Pump-probe measurement of atomic parity violation in caesium with a precision of 2.6 by Lintz, Michel, Guéna, Jocelyne, Bouchiat, Marie-Anne

    “…We present the atomic parity violation measurements made in Cs vapour using a pump-probe scheme. After pulsed excitation of the 6S-7S forbidden transition in…”
    Get full text
    Journal Article
  14. 14

    Experimental demonstration of intermodulation effects in a continuous cesium fountain microwave frequency standard by Guena, J., Dudle, G., Plimmer, M.D., Thomann, P.

    “…The short-term stability of passive atomic frequency standards, particularly ones operated sequentially, is often limited by local oscillator noise via…”
    Get full text
    Conference Proceeding
  15. 15

    New manifestation of atomic parity violation in cesium: a chiral optical gain induced by linearly polarized 6S-7S excitation by Guéna, J, Chauvat, D, Jacquier, Ph, Jahier, E, Lintz, M, Sanguinetti, S, Wasan, A, Bouchiat, M A, Papoyan, A V, Sarkisyan, D

    Published in Physical review letters (11-04-2003)
    “…We have detected, by using stimulated emission, an atomic parity violation (APV) in the form of a chiral optical gain of a cesium vapor on the 7S-6P(3/2)…”
    Get full text
    Journal Article
  16. 16

    Performances of UTC(OP) based on LNE-SYRTE atomic fountains by Rovera, G. D., Abgrall, M., Bize, S., Chupin, B., Guena, J., Laurent, Ph, Rosenbusch, P., Uhrich, P.

    “…We present the current realization of UTC(OP) generated at LNE-SYRTE, Observatoire de Paris (OP), Paris, France, which is also the source of French legal time…”
    Get full text
    Conference Proceeding Journal Article
  17. 17

    Demonstration of an optical polarization magnifier with low birefringence by Lintz, Michel, Guena, Jocelyne, Bouchiat, Marie-Anne, Chauvat, Dominique

    Published 07-10-2004
    “…Review of Scientific Instruments 76 (2005) 043102 In any polarimetric measurement technique, enhancing the laser polarization change of a laser beam before it…”
    Get full text
    Journal Article
  18. 18

    New feature in selective reflection with a highly parallel window: phase-tunable homodyne detection of the radiated atomic field by PAPOYAN, A. V, GRIGORYAN, G. G, SHMAVONYAN, S. V, SARKISYAN, D, GUENA, J, LINTZ, M, BOUCHIAT, M. A

    “…Selective reflection (SR) of light from a cesium vapor-sapphire interface close to the D-2 resonance line has been studied by use of a sapphire window with…”
    Get full text
    Journal Article
  19. 19

    New measurement of the $1S-3S$ transition frequency of hydrogen: contribution to the proton charge radius puzzle by Fleurbaey, Hélène, Galtier, Sandrine, Thomas, Simon, Bonnaud, Marie, Julien, Lucile, Biraben, François, Nez, François, Abgrall, Michel, Guéna, Jocelyne

    Published 26-01-2018
    “…Phys. Rev. Lett. 120, 183001 (2018) We present a new measurement of the $1S-3S$ two-photon transition frequency of hydrogen, realized with a continuous-wave…”
    Get full text
    Journal Article
  20. 20

    Temperature-tunable sapphire windows for reflection loss-free operation of vapor cells by Jahier, E., Guéna, J., Jacquier, Ph, Lintz, M., Papoyan, A.V., Bouchiat, M.A.

    Published in Applied physics. B, Lasers and optics (01-10-2000)
    “…We have developed a 'temperature-tunable cell', for which the reflected intensity of a laser beam on a chosen window can be reduced below 0.5% of the incident…”
    Get full text
    Journal Article