Search Results - "Groza, Voicu Z."
-
1
Oscillometric Blood Pressure Estimation: Past, Present, and Future
Published in IEEE reviews in biomedical engineering (2015)“…The use of automated blood pressure (BP) monitoring is growing as it does not require much expertise and can be performed by patients several times a day at…”
Get full text
Journal Article -
2
Uncertainty in Blood Pressure Measurement Estimated Using Ensemble-Based Recursive Methodology
Published in Sensors (Basel, Switzerland) (08-04-2020)“…Automated oscillometric blood pressure monitors are commonly used to measure blood pressure for many patients at home, office, and medical centers, and they…”
Get full text
Journal Article -
3
Event Recognition for Contactless Activity Monitoring Using Phase-Modulated Continuous Wave Radar
Published in IEEE transactions on biomedical engineering (01-02-2017)“…Objectives: The use of remote sensing technologies such as radar is gaining popularity as a technique for contactless detection of physiological signals and…”
Get full text
Journal Article -
4
Design and Experimental Measurement of EMI Reduction Techniques for Integrated Switching DC/DC Converters
Published in Canadian journal of electrical and computer engineering (2017)“…This paper presents the design and verification of electromagnetic interference (EMI) reduction techniques for switching dc/dc converters. A 48-V dc/dc…”
Get full text
Journal Article -
5
Oscillometric blood pressure estimation by combining nonparametric bootstrap with Gaussian mixture model
Published in Computers in biology and medicine (01-06-2017)“…Abstract Background : Blood pressure (BP) is one of the most important vital indicators and plays a key role in determining the cardiovascular activity of…”
Get full text
Journal Article -
6
Metrological Characterization of a Method for Blood Pressure Estimation Based on Arterial Lumen Area Model
Published in IEEE transactions on instrumentation and measurement (01-04-2017)“…Accuracy of blood pressure (BP) measurement is a challenging issue in oscillometry. Most of the automated noninvasive BP monitors estimate BP from envelope of…”
Get full text
Journal Article -
7
Coefficient-Free Blood Pressure Estimation Based on Pulse Transit Time-Cuff Pressure Dependence
Published in IEEE transactions on biomedical engineering (01-07-2013)“…Oscillometry is a popular technique for automatic estimation of blood pressure (BP). However, most of the oscillometric algorithms rely on empirical…”
Get full text
Journal Article -
8
Characteristic Ratio-Independent Arterial Stiffness-Based Blood Pressure Estimation
Published in IEEE journal of biomedical and health informatics (01-09-2017)“…Noninvasive blood pressure (BP) measurement is an important tool for managing hypertension and cardiovascular disease. However, automated noninvasive BP…”
Get full text
Journal Article -
9
An Integrated Blood Pressure Measurement System for Suppression of Motion Artifacts
Published in Computer methods and programs in biomedicine (01-07-2017)“…Highlights • An algorithm based on Empirical Mode Decomposition to supress the effect of both transient motion artifacts and vibration during the blood…”
Get full text
Journal Article -
10
Oscillometric Blood Pressure Estimation Based on Maximum Amplitude Algorithm Employing Gaussian Mixture Regression
Published in IEEE transactions on instrumentation and measurement (01-12-2013)“…This paper introduces a novel approach to estimate the systolic and diastolic blood pressure ratios (SBPR and DBPR) based on the maximum amplitude algorithm…”
Get full text
Journal Article -
11
Ratio-Independent Blood Pressure Estimation by Modeling the Oscillometric Waveform Envelope
Published in IEEE transactions on instrumentation and measurement (01-10-2014)“…Oscillometry is the most common measurement method used in electronic blood pressure (BP) monitors. However, most of the existing oscillometric algorithms…”
Get full text
Journal Article -
12
Feature-Based Neural Network Approach for Oscillometric Blood Pressure Estimation
Published in IEEE transactions on instrumentation and measurement (01-08-2011)“…In this paper, we present a novel feature-based neural network (NN) approach for estimation of blood pressure (BP) from wrist oscillometric measurements…”
Get full text
Journal Article -
13
Bayesian fusion algorithm for improved oscillometric blood pressure estimation
Published in Medical engineering & physics (01-11-2016)“…Highlights • Oscillometric blood pressure estimation algorithms are fused for better performance. • The goal is to exploit the advantages of the oscillometric…”
Get full text
Journal Article -
14
Estimated confidence interval from single blood pressure measurement based on algorithmic fusion
Published in Computers in biology and medicine (01-07-2015)“…Abstract Background : Current oscillometric blood pressure measurement devices generally provide only single-point estimates for systolic and diastolic blood…”
Get full text
Journal Article -
15
Confidence Interval Estimation for Oscillometric Blood Pressure Measurements Using Bootstrap Approaches
Published in IEEE transactions on instrumentation and measurement (01-10-2011)“…Although estimation of average blood pressure is commonly done with oscillometric measurements, confidence intervals (CIs) for systolic blood pressure (SBP)…”
Get full text
Journal Article -
16
Extraction of Breathing Signal and Suppression of Its Effects in Oscillometric Blood Pressure Measurement
Published in IEEE transactions on instrumentation and measurement (01-05-2011)“…Breathing causes fluctuations in blood pressure and contributes to variations in blood pressure estimates. In order to reduce the variability in the blood…”
Get full text
Journal Article -
17
Spirometer and sEMG respiratory patterns for clinical decision support system
Published in 2023 IEEE International Instrumentation and Measurement Technology Conference (I2MTC) (22-05-2023)“…To improve support system for subjects with respiratory ailments, this work analyses the respiratory patterns from spirometer and surface electromyography…”
Get full text
Conference Proceeding -
18
Adaptive R-Peak Detector in Extreme Noise Using EMD Selective Analyzer
Published in 2022 IEEE International Symposium on Medical Measurements and Applications (MeMeA) (22-06-2022)“…Accurately detecting R-peaks in electrocardiogram (ECG) signals is important in various health monitoring applications, such as cuffless blood pressure…”
Get full text
Conference Proceeding -
19
Entangled Bimodal Vision in Vehicles for Decision During Risk Situation
Published in 2022 IEEE International Workshop on Metrology for Automotive (MetroAutomotive) (04-07-2022)“…On the foundation of a cost-effective embedded system, this work integrates the principles of entanglement and learned simulated flows in a vehicular vision…”
Get full text
Conference Proceeding -
20
Intelligent Parking Vehicle Identification and Classification System
Published in 2021 IEEE International Workshop on Metrology for Automotive (MetroAutomotive) (01-07-2021)“…In this paper, we propose an intelligent system for identification and classification of parking vehicles. The proposed system uses artificial intelligence and…”
Get full text
Conference Proceeding