Novel SOI-Biosensor Topology for the Detection of an Acute Myocardial Infarction Marker - Troponin I
A biosensor based on field-effect transistors on silicon-on-insulator structures (SOI-biosensor) is a high-potential device for detection of biological molecules, for instance, such as troponin I; the biosensor allows conducting label-free real-time analysis. is the development of SOI-biosensor desi...
Saved in:
Published in: | Sovremennye tekhnologii v medit͡s︡ine Vol. 16; no. 1; pp. 37 - 43 |
---|---|
Main Authors: | , , , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
Russia (Federation)
Privolzhsky Research Medical University
01-01-2024
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | A biosensor based on field-effect transistors on silicon-on-insulator structures (SOI-biosensor) is a high-potential device for detection of biological molecules, for instance, such as troponin I; the biosensor allows conducting label-free real-time analysis.
is the development of SOI-biosensor design for detection of acute myocardial infarction marker - troponin I. A notable feature of this design was the integration of two grounding electrodes directly onto the biosensor surface, which effectively nullified the static potential of the liquid sample and minimized physical breakdowns of biosensor elements.
The highly specific anti-troponin I DNA aptamer was used as a receptor for specific detection of protein marker. Aptamer immobilization on the biosensor surface was carried out by physical adsorption. The analyzed range of target troponin I molecules concentration in the sample varied within 10
to 10
mol/L, mirroring clinical levels observed in myocardial infarction cases. During the experiment, a constant voltage of V
=0.15 V was maintained.
The developed SOI-biosensor successfully detected target troponin I molecules at a concentration of 10
mol/L. The detection process exhibited an effective time of approximately 200-300 s per sample. Moreover, analysis of the detection process revealed a noticeable decrease in current within the source-drain circuit, indicative of the negatively charged complex formed by troponin I and anti-troponin I DNA-aptamer at the "liquid sample-nanowire" phase interface. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 Conflicts of interest. The authors have no conflicts of interest to declare. How to cite: Cheremiskina A.A., Krasitskaya V.V., Generalov V.M., Frank L.A., Glukhov A.V., Kruchinina M.V., Kudrov G.A., Serdyuk D.E., Grabezhova V.K. Novel SOI-biosensor topology for the detection of an acute myocardial infarction marker — troponin I. Sovremennye tehnologii v medicine 2024; 16(1): 37, https://doi.org/10.17691/stm2024.16.1.04 |
ISSN: | 2076-4243 2309-995X 2309-995X |
DOI: | 10.17691/stm2024.16.1.04 |