Search Results - "Goor, D"

Refine Results
  1. 1

    The Synthesis of Substituted Benzo[c]chromen-6-ones by a Suzuki Coupling and Lactonization Sequence Using Ionic Liquids - from Laboratory Scale to Multi-Kilogram Synthesis by Kemperman, Gerardus J., Ter Horst, B., Van de Goor, D., Roeters, T., Bergwerff, J., Van der Eem, R., Basten, J.

    Published in European Journal of Organic Chemistry (01-07-2006)
    “…A series of benzo[c]chromen‐6‐ones are prepared by a Suzuki coupling and lactonization sequence starting with 2‐methoxyphenylboronic acids and methyl…”
    Get full text
    Book Review Journal Article
  2. 2

    Dad1p, third component of the Duo1p/Dam1p complex involved in kinetochore function and mitotic spindle integrity by Enquist-Newman, M, Cheeseman, I M, Van Goor, D, Drubin, D G, Meluh, P B, Barnes, G

    Published in Molecular biology of the cell (01-09-2001)
    “…We showed recently that a complex between Duo1p and Dam1p is required for both spindle integrity and kinetochore function in the budding yeast Saccharomyces…”
    Get full text
    Journal Article
  3. 3

    Analyses and design of bias circuits tolerating output voltages above BV/sub CEO by Veenstra, H., Hurkx, G.A.M., van Goor, D., Brekelmans, H., Long, J.R.

    Published in IEEE journal of solid-state circuits (01-10-2005)
    “…Due to the inevitable tradeoff between speed and breakdown voltage, the spectacular speed improvement of modern SiGe processes in recent history has partially…”
    Get full text
    Journal Article
  4. 4

    An ultra-low-power 868/915 MHz RF transceiver for wireless sensor network applications by van Langevelde, R., van Elzakker, M., van Goor, D., Termeer, H., Moss, J., Davie, A.J.

    “…This paper describes an ultra-low-power RF transceiver implemented as part of a system-on-chip. The transceiver operates in the 868/915 MHz frequency band…”
    Get full text
    Conference Proceeding
  5. 5

    Clamping of the atherosclerotic ascending aorta during coronary artery bypass operations. Its cost in strokes by Bar-El, Y, Goor, D A

    “…In 632 consecutive primary operations for coronary bypass grafting, the effect of instrumentation of the ascending aorta on the prevalence of stroke was…”
    Get more information
    Journal Article
  6. 6

    The hemostatic effect of transfusing fresh whole blood versus platelet concentrates after cardiac operations by Mohr, R, Martinowitz, U, Lavee, J, Amroch, D, Ramot, B, Goor, D A

    “…The major cause of nonsurgical bleeding after cardiopulmonary bypass is delayed recovery of platelet count and function. Recovery of platelet count and…”
    Get more information
    Journal Article
  7. 7

    15-27 GHz pseudo-noise UWB transmitter for short-range automotive radar in a production SiGe technology by Veenstra, H., van der Heijden, E., van Goor, D.

    “…Short-range radar is a technology that potentially can help to enhance road safety. Recently, in the USA as well as in Europe, frequency bands around 24 GHz…”
    Get full text
    Conference Proceeding
  8. 8

    Inaccuracy of radial artery pressure measurement after cardiac operations by Mohr, R, Lavee, J, Goor, D A

    “…The phenomenon of a pressure gradient between central and radial arteries was evaluated in 48 patients immediately after coronary artery bypass operations. All…”
    Get more information
    Journal Article
  9. 9

    Platelet protection by aprotinin in cardiopulmonary bypass: Electron microscopic study by Lavee, Jacob, Savion, Naphtali, Smolinsky, Aram, Goor, Daniel A., Mohr, Rephael

    Published in The Annals of thoracic surgery (01-03-1992)
    “…To evaluate the functional integrity of platelets in patients administered the proteinase inhibitor aprotinin during cardiopulmonary bypass, 20 patients…”
    Get full text
    Journal Article
  10. 10

    The effect of transfusion of fresh whole blood versus platelet concentrates after cardiac operations. A scanning electron microscope study of platelet aggregation on extracellular matrix by Lavee, J, Martinowitz, U, Mohr, R, Goor, D A, Golan, M, Langsam, J, Malik, Z, Savion, N

    “…To evaluate the effect of fresh whole blood transfusion versus platelet concentrates transfusion on platelet aggregation after cardiac operations, 24 patients…”
    Get more information
    Journal Article
  11. 11

    Octave tunable, highly linear, RC-ring oscillator with differential fine-coarse tuning, quadrature outputs and amplitude control for fiber optic transceivers by Sanduleanu, M.A.T., van Goor, D., Veenstra, H.

    “…This paper presents a low-voltage, RC-ring oscillator for fiber optic transceivers (SDH/SONET applications). It has one octave coarse tuning range,…”
    Get full text
    Conference Proceeding Journal Article
  12. 12

    Platelet protection by low-dose aprotinin in cardiopulmonary bypass: Electron microscopic study by Lavee, Jacob, Raviv, Zvi, Smolinsky, Aram, Savion, Naphtali, Varon, David, Goor, Daniel A., Mohr, Rephael

    Published in The Annals of thoracic surgery (01-01-1993)
    “…To evaluate the effect of low-dose aprotinin during cardiopulmonary bypass on platelet function and clinical hemostasis, 30 patients undergoing various…”
    Get full text
    Journal Article
  13. 13

    Synergism between infarct-borne left ventricular dysfunction and cardiomegaly in increasing the risk of coronary bypass surgery by Goor, D A, Golan, M, Bar-El, Y, Modan, M, Lusky, A, Rozenman, J, Mohr, R

    “…The effect of cardiomegaly on operative and late mortality in patients with left ventricular dysfunction undergoing coronary bypass operation was investigated…”
    Get more information
    Journal Article
  14. 14

    Effect of cardiac operation on platelets by Mohr, R, Golan, M, Martinowitz, U, Rosner, E, Goor, D A, Ramot, B

    “…The effect of extracorporeal circulation on platelet count and size (mean platelet volume) was studied in 65 patients (nine bleeders and 56 nonbleeders). In…”
    Get more information
    Journal Article
  15. 15

    Is transfusion of fresh plasma after cardiac operations indicated? by Martinowitz, U, Goor, D A, Ramot, B, Mohr, R

    “…Patients undergoing cardiac operations constitute the majority of recipients of fresh frozen plasma. In most centers the reason for transfusing fresh frozen…”
    Get more information
    Journal Article
  16. 16

    Irradiation of fresh whole blood for prevention of transfusion-associated graft-versus-host disease does not impair platelet function and clinical hemostasis after open heart surgery by Lavee, J, Shinfeld, A, Savion, N, Thaler, M, Mohr, R, Goor, D A

    Published in Vox sanguinis (01-01-1995)
    “…Since our previous studies suggested that the transfusion of 1 unit fresh whole blood (FWB) after cardiopulmonary bypass (CPB) using a bubble oxygenator may…”
    Get more information
    Journal Article
  17. 17

    Transfusion of fresh whole blood stored (4 degrees C) for short period fails to improve platelet aggregation on extracellular matrix and clinical hemostasis after cardiopulmonary bypass by Golan, M, Modan, M, Lavee, J, Martinowitz, U, Savion, N, Goor, D A, Mohr, R

    “…It has recently been shown that the hemostatic effect of 1 unit of fresh whole blood is equivalent to the effect of 8 to 10 platelet units. This study was…”
    Get more information
    Journal Article
  18. 18
  19. 19

    Surgical closed pulmonary valvotomy for critical pulmonary stenosis: implications for the balloon valvuloplasty era by Smolinsky, A, Arav, R, Hegesh, J, Lusky, A, Goor, D A

    Published in Thorax (01-03-1992)
    “…BACKGROUND: Closed pulmonary valvotomy for critical pulmonary stenosis has no apparent advantage over the percutaneous balloon technique, though it is used…”
    Get full text
    Journal Article Conference Proceeding
  20. 20

    Preservation of the posterior leaflet during mechanical valve replacement for ischemic mitral regurgitation and complete myocardial revascularization by Goor, D A, Mohr, R, Lavee, J, Serraf, A, Smolinsky, A

    “…Between 1980 and 1987, 40 patients with ischemic mitral insufficiency underwent mitral valve replacement (with a mechanical prosthesis) and coronary bypass…”
    Get more information
    Journal Article