Search Results - "Goedbloed, Martijn"
-
1
Flexible, electrostatic microfluidic actuators based on thin film fabrication
Published in Sensors and actuators. A. Physical. (01-10-2012)“…► We presented design and fabrication of microvalve for on-chip fluid handling. ► Microvalve was made on flexible substrate technology and with biocompatible…”
Get full text
Journal Article -
2
A MALDI-chip integrated system with a monitoring window
Published in Lab on a chip (01-01-2005)“…The integration of a monitoring port along the microfluidic path of a MALDI-chip integrated device is described. Optimization of the microreactor design allows…”
Get more information
Journal Article -
3
Adhesion and patterning of cortical neurons on polyethylenimine- and fluorocarbon-coated surfaces
Published in IEEE transactions on biomedical engineering (01-12-2000)“…Adhesion and patterning of cortical neurons was investigated on isolated islands of neuron-adhesive polyethylenimine (PEI) surrounded by a neuron-repellent…”
Get full text
Journal Article -
4
Solid-Contact Reference Electrode for Ion-Selective Sensors
Published in Proceedings (01-08-2017)“…This work presents a flexible miniaturized ion-selective sensor consisting of a solid-contact reference electrode (RE) and ion-selective electrodes (ISE)…”
Get full text
Journal Article -
5
-
6
Charge injection and storage in single-layer and multilayer inorganic electrets based on SiO2 and Si3N4
Published in IEEE transactions on dielectrics and electrical insulation (01-08-2012)“…It is shown that the maximum surface potential in inorganic electrets is limited by the breakdown of the dielectric layer. It is observed that several…”
Get full text
Journal Article -
7
Integrated Microfluidic System Enabling (Bio)chemical Reactions with On-Line MALDI-TOF Mass Spectrometry
Published in Analytical chemistry (Washington) (15-08-2002)“…A continuous flow micro total analysis system (μ-TAS) consisting of an on-chip microfluidic device connected to a matrix assisted laser desorption ionization…”
Get full text
Journal Article -
8
Fine patterning of electrets for sensors and energy harvesters
Published in 2012 IEEE Sensors (01-10-2012)“…Charge patterning on 1.3 μm-wide electret lines has successfully been demonstrated with a voltage of 80 V between charged Si 3 N 4 lines and discharged…”
Get full text
Conference Proceeding -
9
A Microfabricated 4-Electrode Conductivity Sensor with Enhanced Range
Published in Proceedings (01-12-2018)“…Conductivity is a routinely measured parameter to assess impurities in water. Changing the geometry from parallel plate electrodes to planar microfabricated…”
Get full text
Journal Article