Search Results - "Gimon, Mary E"

  • Showing 1 - 12 results of 12
Refine Results
  1. 1

    Pulsed laser deposition of mesoporous niobium oxide thin films and application as chemical sensors by Gimon-Kinsel, Mary E, Balkus, Kenneth J

    Published in Microporous and mesoporous materials (01-03-1999)
    “…The pulsed laser deposition (PLD) of a mesoporous niobium oxide, Nb-TMS1, and post-hydrothermal treatment result in mesoporous thin films (90 nm–3 μm thick)…”
    Get full text
    Journal Article
  2. 2

    Investigation of the dynamics of matrix-assisted laser desorption/ionization ion formation using an electrostatic analyzer/time-of-flight mass spectrometer by Kinsel, Gary R., Gimon-Kinsel, Mary E., Gillig, Kent J., Russell, David H.

    Published in Journal of mass spectrometry. (01-06-1999)
    “…A hybrid electrostatic analyzer/time‐of‐flight mass spectrometer was used to examine the matrix‐assisted laser desorption/ionization (MALDI) ion kinetic energy…”
    Get full text
    Journal Article
  3. 3

    Global Chirality in Rigid Decametallic Ruthenium Dendrimers by Kim, Mahn-Jong, MacDonnell, Frederick M., Gimon-Kinsel, Mary E., Du Bois, Thomas, Asgharian, Niloofar, Griener, James C.

    Published in Angewandte Chemie International Edition (04-02-2000)
    “…Metallodendrimers with ten chiral Ru centers have been prepared in a stereospecific fashion (see picture; •=chiral Ru(diimine)3 center). These molecules are…”
    Get full text
    Journal Article
  4. 4
  5. 5

    Matrix-Assisted Laser Desorption/Ionization Time-of-flight Mass Spectrometry of Paclitaxel and Related Taxanes by Gimon, Mary E, Kinsel, Gary R, Edmondson, Ricky D, Russell, David H, Prout, Timothy R, Ewald, Hernita A

    “…Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry has been demonstrated for the analysis of Taxus brevifolia extracts. The detection…”
    Get full text
    Journal Article
  6. 6

    Conformations of protonated gas-phase bradykinin ions: evidence for intramolecular hydrogen bonding by Gimon-Kinsel, Mary E., Barbacci, Damon C., Russell, David H.

    Published in Journal of mass spectrometry. (01-02-1999)
    “…The post‐source decay of bradykinin, Lys1‐bradykinin, des‐Arg1‐bradykinin, des‐Arg9‐bradykinin and [D‐Phe7]‐bradykinin [M+H]+ ions was examined in order to…”
    Get full text
    Journal Article
  7. 7

    A capacitance-type chemical sensor that employs VAPO-5, MnAPO-5 and MAPO-36 molecular sieves as the dielectric phase by Balkus, Kenneth J, Ball, Laura J, Gimon-Kinsel, Mary E, Anthony, J.Mark, Gnade, Bruce E

    Published in Sensors and actuators. B, Chemical (15-07-1997)
    “…We have developed a chemical sensor based on a capacitor design that utilizes molecular sieves as the dielectric phase. In this study, thin films of vanadium…”
    Get full text
    Journal Article
  8. 8

    Global Chirality in Rigid Decametallic Ruthenium Dendrimers by Kim, Mahn-Jong, MacDonnell, Frederick M., Gimon-Kinsel, Mary E., Du Bois, Thomas, Asgharian, Niloofar, Griener, James C.

    Published in Angewandte Chemie (04-02-2000)
    “…Metallodendrimere mit zehn chiralen Ru‐Zentren wurden stereospezifisch hergestellt (siehe Bild; •=chirales Ru(diimin)3‐Zentrum). Diese Moleküle sind…”
    Get full text
    Journal Article
  9. 9

    Photoluminescent properties of MCM-41 molecular sieves by Gimon-Kinsel, Mary E., Groothuis, Kathy, Balkus, Kenneth J.

    Published in Microporous and mesoporous materials (01-02-1998)
    “…The photoluminescence of as-synthesized and calcined siliceous as well as aluminosilicate MCM-41 molecular sieves was examined at 350, 300, 250 and 200 nm. The…”
    Get full text
    Journal Article
  10. 10
  11. 11

    Oriented films of mesoporous MCM-41 macroporous tubules via pulsed laser deposition by Balkus, Kenneth J., Scott, Ashley S., Gimon-Kinsel, Mary E., Blanco, Justo H.

    Published in Microporous and mesoporous materials (01-07-2000)
    “…All-silica mesoporous MCM-41 molecular sieve films consisting of oriented macroporous tubules have been prepared utilizing pulsed laser deposition and a series…”
    Get full text
    Journal Article
  12. 12

    Photodissociation of High Molecular Weight Peptides and Proteins in a Two-Stage Linear Time-Of-Flight Mass Spectrometer by Gimon-Kinsel, Mary E., Kinsel, Gary R., Edmondson, Ricky D., Russell, David H.

    “…A two-stage linear time-of-flight mass spectrometer is used to investigate the requirements for performance of laser photodissociation of peptide and protein…”
    Get full text
    Journal Article