Search Results - "Gibreel, Mona"

Refine Results
  1. 1

    Evaluation of the mechanical properties and degree of conversion of 3D printed splint material by Perea-Lowery, Leila, Gibreel, Mona, Vallittu, Pekka K., Lassila, Lippo

    “…To evaluate the effect of post-curing method, printing layer thickness, and water storage on the mechanical properties and degree of conversion of a…”
    Get full text
    Journal Article
  2. 2

    Two-body wear and surface hardness of occlusal splint materials by GIBREEL, Mona, PEREA-LOWERY, Leila, VALLITTU, Pekka K., GAROUSHI, Sufyan, LASSILA, Lippo

    Published in Dental Materials Journal (25-11-2022)
    “…The aim of this in vitro study was to evaluate the wear and surface hardness of nine materials for conventional manufacturing, subtractive milling, and 3D…”
    Get full text
    Journal Article
  3. 3

    3D-Printed vs. Heat-Polymerizing and Autopolymerizing Denture Base Acrylic Resins by Perea-Lowery, Leila, Gibreel, Mona, Vallittu, Pekka K., Lassila, Lippo V.

    Published in Materials (03-10-2021)
    “…The aim of this work was to investigate the effect of two post-curing methods on the mechanical properties of a 3D-printed denture base material. Additionally,…”
    Get full text
    Journal Article
  4. 4

    Characterization of occlusal splint materials: CAD-CAM versus conventional resins by Gibreel, Mona, Perea-Lowery, Leila, Vallittu, Pekka K., Lassila, Lippo

    “…The aim of this in vitro study was to assess the mechanical properties of five commercially available subtractive computer-aided design and computer-aided…”
    Get full text
    Journal Article
  5. 5

    Characterization of the mechanical properties of CAD/CAM polymers for interim fixed restorations by PEREA-LOWERY, Leila, GIBREEL, Mona, VALLITTU, Pekka K., LASSILA, Lippo

    Published in Dental Materials Journal (27-03-2020)
    “…This study investigated some mechanical properties of five CAD/CAM materials used for the fabrication of provisional restorations and tooth segments for…”
    Get full text
    Journal Article
  6. 6

    Effect of Nitrogen Gas Post-Curing and Printer Type on the Mechanical Properties of 3D-Printed Hard Occlusal Splint Material by Wada, Junichiro, Wada, Kanae, Gibreel, Mona, Wakabayashi, Noriyuki, Iwamoto, Tsutomu, Vallittu, Pekka K., Lassila, Lippo

    Published in Polymers (22-09-2022)
    “…Although three-dimensional (3D) printing is clinically convenient to fabricate occlusal splints, it is still unclear how the post-curing method and the printer…”
    Get full text
    Journal Article
  7. 7

    Mechanical Properties Evaluation of Three Different Materials for Implant Supported Overdenture: An In-Vitro Study by Gibreel, Mona, Perea-Lowery, Leila, Lassila, Lippo, Vallittu, Pekka K

    Published in Materials (02-10-2022)
    “…Aim: the aim of this study was to compare the flexural strength and elastic modulus of three-dimensionally (3D) printed, conventional heat-cured, and…”
    Get full text
    Journal Article
  8. 8

    Effect of 3D Printer Type and Use of Protection Gas during Post-Curing on Some Physical Properties of Soft Occlusal Splint Material by Wada, Junichiro, Wada, Kanae, Gibreel, Mona, Wakabayashi, Noriyuki, Iwamoto, Tsutomu, Vallittu, Pekka K, Lassila, Lippo

    Published in Polymers (31-10-2022)
    “…Despite the fact that three-dimensional (3D) printing is frequently used in the manufacturing of occlusal splints, the effects of the 3D printer type and…”
    Get full text
    Journal Article
  9. 9

    Effect of Surface Polishing on Physical Properties of an Occlusal Splint Material for Additive Manufacturing under Protection Gas Post-Curing Condition by Wada, Junichiro, Wada, Kanae, Gibreel, Mona, Wakabayashi, Noriyuki, Iwamoto, Tsutomu, Vallittu, Pekka K, Lassila, Lippo

    Published in Polymers (25-01-2023)
    “…The aim of this study was to evaluate the effect of surface polishing as well as the post-curing atmospheres (air and nitrogen gas) on the physical properties…”
    Get full text
    Journal Article
  10. 10

    Effect of Implant Location on Palateless Complete Overdenture Retention: an In Vitro Study by El-Amier, Nesma, Elsaih, Ehab, Gibreel, Mona, El-Motaiam, Hassan

    Published in Journal of oral & maxillofacial research (30-09-2018)
    “…The purpose of this study was to evaluate effect of implant location on initial retention values of palateless complete overdentures retained by four o-rings…”
    Get full text
    Journal Article
  11. 11

    Biomechanical aspects of reinforced implant overdentures: A systematic review by Gibreel, Mona Fathy, Khalifa, Ahmed, Said, Mohamed Moustafa, Mahanna, Fatma, El-Amier, Nesma, Närhi, Timo O, Perea-Lowery, Leila, Vallittu, Pekka K

    “…The purpose of this systematic review was to investigate the effect of reinforcement on the mechanical behaviour of implant overdenture (IOD) bases and its…”
    Get full text
    Journal Article
  12. 12

    Evaluation of flexible three-dimensionally printed occlusal splint materials: An in vitro study by Perea-Lowery, Leila, Gibreel, Mona, Garoushi, Sufyan, Vallittu, Pekka, Lassila, Lippo

    Published in Dental materials (01-10-2023)
    “…To evaluate and compare the mechanical properties, water sorption, water solubility, and degree of double bond conversion of three different commercially…”
    Get full text
    Journal Article
  13. 13

    Characterization of the mechanical properties of CAD/CAM polymers for interim fixed restorations by PEREA-LOWERY, Leila, GIBREEL, Mona, VALLITTU, Pekka K., LASSILA, Lippo

    Published in Dental Materials Journal (2020)
    “…This study investigated some mechanical properties of five CAD/CAM materials used for the fabrication of provisional restorations and tooth segments for…”
    Get full text
    Journal Article
  14. 14

    Two-body wear and surface hardness of occlusal splint materials by GIBREEL, Mona, PEREA-LOWERY, Leila, VALLITTU, Pekka K., GAROUSHI, Sufyan, LASSILA, Lippo

    Published in Dental Materials Journal (2022)
    “…The aim of this in vitro study was to evaluate the wear and surface hardness of nine materials for conventional manufacturing, subtractive milling, and 3D…”
    Get full text
    Journal Article
  15. 15

    Midline denture base strains of glass fiber-reinforced single implant-supported overdentures by Gibreel, Mona, Lassila, Lippo V.J., Närhi, Timo O., Perea-Lowery, Leila, Vallittu, Pekka K.

    Published in The Journal of prosthetic dentistry (01-09-2021)
    “…The fracture incidence of implant-supported overdentures is more frequent in the area of attachment because of stress concentration and denture deformation in…”
    Get full text
    Journal Article
  16. 16

    Effect of specific retention biomaterials for ball attachment on the biomechanical response of single implant-supported overdenture: A finite element analysis by Gibreel, Mona, Sameh, Ahmed, Hegazy, Salah, Närhi, Timo O., Vallittu, Pekka K., Perea-Lowery, Leila

    “…The purpose of this finite element analysis (FEA) was to evaluate the effect of specific retention biomaterials with different elastic modulus on the…”
    Get full text
    Journal Article
  17. 17

    Flexural strength and flexural modulus of fiber-reinforced, soft-liner retained implant overdenture by Gibreel, Mona, Lassila, Lippo Vj, Närhi, Timo O, Perea-Lowery, Leila, Vallittu, Pekka K

    “…To compare the flexural strength and modulus of ball-soft liner–retained overdentures vs ballsocket– retained overdentures, as well as to evaluate the effect…”
    Get more information
    Journal Article
  18. 18

    Fatigue resistance of a simulated single LOCATOR overdenture system by Gibreel, Mona, Lassila, Lippo V.J., Närhi, Timo O., Perea-Lowery, Leila, Vallittu, Pekka K.

    Published in The Journal of prosthetic dentistry (01-12-2019)
    “…The incidence of fracture in a single-implant overdenture base increases in the region adjacent to the fulcrum implant. The purpose of this in vitro study was…”
    Get full text
    Journal Article
  19. 19
  20. 20

    Load-bearing capacity of simulated Locator-retained overdenture system by Gibreel, Mona, Lassila, Lippo V.J., Närhi, Timo O., Perea-Lowery, Leila, Vallittu, Pekka K.

    Published in The Journal of prosthetic dentistry (01-10-2018)
    “…Acrylic resin overdenture bases usually fracture because of stress concentrations at the area of the abutments. The purpose of this study was to evaluate the…”
    Get full text
    Journal Article