Search Results - "Gasparotto, E"

Refine Results
  1. 1
  2. 2

    Inter-laboratories comparison at 100 G Omega and 1 T Omega level to evaluate the traceability transfer from INRIM in the field of high dc resistance by Galliana, F, Capra, P P, Gasparotto, E

    “…A National inter-laboratories comparison of dc resistance at 100 G Omega and 1 T Omega among the National Institute of Metrological Research (INRIM) and eight…”
    Get full text
    Journal Article
  3. 3

    Metrological management of the high dc resistance scale at INRIM by Galliana, F., Capra, P.P., Gasparotto, E.

    “…In the framework of the revision of the high dc resistance scale from 10kΩ to 1TΩ at National Institute of Metrological Research (INRIM) a measurement method…”
    Get full text
    Journal Article
  4. 4

    Report of the Italian inter-laboratories comparison of high dc resistance on the calibration of a and a resistors by Galliana, F, Capra, P P, Gasparotto, E

    “…A national comparison of high dc resistance at [MathML equation] and [MathML equation] level was organized by the Electromagnetic Division of National…”
    Get full text
    Journal Article
  5. 5
  6. 6

    Impedance comparison at power frequency by asynchronous sampling by Callegaro, L, D'Elia, V, Gasparotto, E

    Published in CPEM 2010 (01-06-2010)
    “…We present a measurement setup for the comparison of four-terminal impedances at power frequency, based on synchronous sampling of the voltage drops on the…”
    Get full text
    Conference Proceeding
  7. 7

    Fabrication and characterization of graphene-based quantum hall effect devices at INRIM by Bruna, M, Cassiago, C, Callegaro, L, Gasparotto, E, Rocci, R, Borini, S

    Published in CPEM 2010 (01-06-2010)
    “…This paper describes the research activity in progress at INRIM about graphene-based devices. This study, aimed at the realization of new quantum resistance…”
    Get full text
    Conference Proceeding
  8. 8

    Analysis of a national comparison in the field of electrical low dc resistance by Galliana, F., Gasparotto, E.

    “…•A comparison on low resistance among INRIM and 19 Laboratories gave positive results.•Three standard resistors were characterized before their…”
    Get full text
    Journal Article
  9. 9

    On the calibration of DC resistance ratio bridges by Marzano, M., Cassiago, C., D’Elia, V., Gasparotto, E., Callegaro, L.

    “…Current comparator bridges are employed for the realization of the resistance scale from the quantum Hall effect in several National Metrology Institutes and…”
    Get full text
    Journal Article
  10. 10

    The IEN CCC bridge to scale the quantized Hall resistance to 1-/spl Omega/ standards by Boella, G., Mihai, I., Marullo-Reedtz, G., Capra, P.P., Gasparotto, E.

    “…A resistance bridge based on a cryogenic current comparator has been built at the Istituto Elettrotecnico Nazionale "G. Ferraris" (IEN). The use of this bridge…”
    Get full text
    Journal Article
  11. 11

    The IEN CCC Bridge to Scale the Quantized Hall Resistance to 1- $Omega$ Standards by Boella, G., Mihai, I., Marullo-Reedtz, G., Capra, P.P., Gasparotto, E.

    “…A resistance bridge based on a cryogenic current comparator has been built at the Istituto Elettrotecnico Nazionale "G. Ferraris" (IEN). The use of this bridge…”
    Get full text
    Journal Article
  12. 12

    Metrological assessment of DC current comparator resistance bridges by Marzano, M., Capra, P.P., Cassiago, C., D’Elia, V., Gasparotto, E., Callegaro, L.

    “…Direct-current comparator bridges (DCC) are the working horses of primary resistance metrology in the intermediate resistance range. Having a ratio accuracy…”
    Get full text
    Journal Article
  13. 13

    Systemic leukocyte filtration during cardiopulmonary bypass by Fabbri, Alessandro, Manfredi, Jacopo, Piccin, Caterina, Soffiati, Giuliano, Carta, Maria Rosa, Gasparotto, Edoardo, Nardon, Giuseppe

    Published in Perfusion (2001)
    “…Cardiopulmonary bypass (CPB) induces a whole body inflammatory response leading to postoperative lung dysfunction. Activated leukocytes may play a role in the…”
    Get full text
    Journal Article
  14. 14

    A traceable technique to calibrate dc current shunts and resistors in the range from 10 I14ICO to 10 mICO by Galliana, F, Capra, P P, Gasparotto, E

    “…A traceable to dc resistance and dc voltage National Standards measurement technique to calibrate dc current shunts and resistors in the range from 10 mu ICO…”
    Get full text
    Journal Article
  15. 15

    A traceable technique to calibrate dc current shunts and resistors in the range from 10μΩ to 10mΩ by Galliana, F., Capra, P.P., Gasparotto, E.

    “…► This technique to calibrate shunts is suitable for secondary laboratories. ► The setup involves standard shunts, power supplies and digital nanovoltmeters. ►…”
    Get full text
    Journal Article
  16. 16
  17. 17

    Dynamics of immunoglobulin sequence diversity in HIV-1 infected individuals by Hoehn, Kenneth B., Gall, Astrid, Bashford-Rogers, Rachael, Fidler, S. J., Kaye, S., Weber, J. N., McClure, M. O., Kellam, Paul, Pybus, Oliver G.

    “…Advances in immunoglobulin (Ig) sequencing technology are leading to new perspectives on immune system dynamics. Much research in this nascent field has…”
    Get full text
    Journal Article
  18. 18

    Inter-laboratories comparison at 100GΩ and 1TΩ level to evaluate the traceability transfer from INRIM in the field of high dc resistance by Galliana, F., Capra, P.P., Gasparotto, E.

    “…► Electrical Metrological Laboratories are traceable to INRIM in different ways. ► Calibrators and DMM can be involved in measurement systems of high…”
    Get full text
    Journal Article
  19. 19

    10x10 G/spl Omega/ Guarded Hamon Network for the Modified Wheatstone Bridge for High Value Resistors Calibration by Galliana, F., Capra, P. P., Gasparotto, E.

    “…At the National Institute of Metrological Research (INRIM), a Hamon guarded 10×100 MΩ network was developed to improve the traceability levels of dc resistance…”
    Get full text
    Journal Article
  20. 20

    Report of the Italian inter-laboratories comparison of high dc resistance on the calibration of a 10 M Ω and a 1 G Ω resistors by Galliana, F., Capra, P.P., Gasparotto, E.

    “…A national comparison of high dc resistance at 10 M Ω and 1 G Ω level was organized by the Electromagnetic Division of National Institute of Metrological…”
    Get full text
    Journal Article