Search Results - "Garutti, Erika"
-
1
Correcting the Non-Linear Response of Silicon Photomultipliers
Published in Sensors (Basel, Switzerland) (05-03-2024)“…The finite number of pixels in a silicon photomultiplier (SiPM) limits its dynamic range to light pulses up to typically 80% of the total number of pixels in a…”
Get full text
Journal Article -
2
Determination of Self-Heating in Silicon Photomultipliers
Published in Sensors (Basel, Switzerland) (01-05-2024)“…The main consequence of radiation damage on a silicon photomultiplier (SiPM) is a significant increase in the dark current. If the SiPM is not adequately…”
Get full text
Journal Article -
3
Study of point- and cluster-defects in radiation-damaged silicon
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-08-2018)“…Non-ionising energy loss of radiation produces point defects and defect clusters in silicon, which result in a significant degradation of sensor performance…”
Get full text
Journal Article -
4
PeakOTron: A Python module for fitting charge spectra of Silicon Photomultipliers
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-11-2023)“…A Python program has been developed which fits a published detector-response model to SiPM charge spectra to characterise SiPMs. Spectra for SiPMs illuminated…”
Get full text
Journal Article -
5
Overview on calorimetry
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-02-2011)“…In this paper I want to review the state of the art of calorimeter developments. I will focus on innovative solutions in calorimetry at the technology frontier…”
Get full text
Journal Article -
6
Radiation hardness of a wide spectral range SiPM with quasi-spherical junction
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-02-2023)“…New pixel geometries are on the rise to achieve high sensitivity in near-infrared wavelengths with silicon photomultipliers (SiPMs). We test prototypes of the…”
Get full text
Journal Article -
7
EndoTOFPET-US a novel multimodal tool for endoscopy and Positron Emission Tomography
Published in 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC) (01-10-2012)“…The EndoTOFPET-US project aims to jointly exploit Time-Of-Flight Positron Emission Tomography (TOFPET) and ultrasound endoscopy with a multi-modal instrument…”
Get full text
Conference Proceeding -
8
Influence of X-ray irradiation on the properties of the Hamamatsu silicon photomultiplier S10362-11-050C
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-10-2014)“…We have investigated the effects of X-ray irradiation to doses of 0, 200Gy, 20kGy, 2MGy, and 20MGy on the Hamamatsu silicon-photomultiplier (SiPM)…”
Get full text
Journal Article -
9
Comparison of digital and analog silicon photomultiplier for positron emission tomography application
Published in 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC) (01-10-2013)“…In recent years, silicon photomultipliers (SiPMs) became popular candidates for applications in positron emission tomography (PET) scanners or PET based…”
Get full text
Conference Proceeding -
10
Towards a multi-channel TOF-PET system with SiPM readout
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-12-2012)“…The goal of this project is to develop a multi-channel TOF-PET system with a 300ps FWHM time resolution, a factor two improvement with respect to commercially…”
Get full text
Journal Article -
11
SiPM Signal Processing via Multiple Linear Regression
Published 24-04-2023“…This paper presents a novel approach using multiple linear regression to process transient signals from silicon photomultipliers. The method provides excellent…”
Get full text
Journal Article -
12
PeakOTron: A Python Module for Fitting Charge Spectra of Silicon Photomultipliers
Published 27-01-2023“…A Python program has been developed which fits a published detector-response model to SiPM charge spectra to characterise SiPMs. Spectra for SiPMs illuminated…”
Get full text
Journal Article -
13
Radiation Hardness of a Wide Spectral Range SiPM with Quasi-Spherical Junction
Published 16-09-2022“…New pixel geometries are on the rise to achieve high sensitivity in near-infrared wavelengths with silicon photomultipliers (SiPMs). We test prototypes of the…”
Get full text
Journal Article -
14
Influence of X-ray irradiation on the properties of the Hamamatsu silicon photomultiplier S10362-11-050C
Published in 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC) (01-10-2013)“…We have investigated the effects of X-ray radiation of doses of 0, 200 Gy, and 20 kGy on the Hamamatsu silicon-photomultiplier (SiPM) S10362-11-050P. From…”
Get full text
Conference Proceeding -
15
Depth-dependent charge collection profile of pad diodes
Published 15-12-2021“…The collected charge of two pad diodes is measured along the diode width using a 5:2 GeV electron beam at the DESY II beam test facility. The electron beam…”
Get full text
Journal Article -
16
Dedicated front-end electronics for an ILC prototype hadronic calorimeter with SiPM readout
Published in IEEE Nuclear Science Symposium Conference Record, 2005 (2005)“…A prototype hadronic calorimeter for the ILC detector is under construction at DESY. It will consist of 8000 scintillator tiles with analog readout performed…”
Get full text
Conference Proceeding -
17
EndoTOFPET-US a Novel Multimodal Tool for Endoscopy and Positron Emission Tomography
Published 19-03-2013“…The EndoTOFPET-US project aims to jointly exploit Time-Of-Flight Positron Emission Tomography (TOFPET) and ultrasound endoscopy with a multi-modal instrument…”
Get full text
Journal Article -
18
Study of depth-dependent charge collection profiles in irradiated pad diodes
Published 26-09-2022“…In this work, charge collection profiles of non-irradiated and irradiated 150 $\mu$m $p$-type pad diodes were measured using a 5.2 GeV electron beam traversing…”
Get full text
Journal Article -
19
Investigation of high resistivity p-type FZ silicon diodes after 60Co {\gamma}-irradiation
Published 27-06-2023“…In this work, the effects of $^\text{60}$Co $\gamma$-ray irradiation on high resistivity $p$-type diodes have been investigated. The diodes were exposed to…”
Get full text
Journal Article -
20
Single channel optimization for an endoscopic time-of-flight positron emission tomography detector
Published in 2011 IEEE Nuclear Science Symposium Conference Record (01-10-2011)“…An endoscopic time-of-flight PET detector combined with an ultrasound probe will be designed and built to develop new biomarkers for pancreas and prostate…”
Get full text
Conference Proceeding