Search Results - "Fragopoulou, M"
-
1
Phenomenological calculations of shielding spallation neutron sources
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-06-2013)“…The high level of radiation generated by a spallation source requires the design of an appropriate shielding to surround the source in order to fulfill…”
Get full text
Journal Article -
2
Electron accelerator driven system for transmutation studies
Published in Journal of radioanalytical and nuclear chemistry (01-11-2018)“…An accelerator driven system has been studied by irradiation with 20 MeV electrons. Slow, intermediate and fast neutrons were measured by activation and Solid…”
Get full text
Journal Article -
3
Application of passive methods for electron flux measurements regarding to 238U electron-disintegration studies
Published in Journal of radioanalytical and nuclear chemistry (2018)“…The electron flux is measured using 238 U targets detecting the (e, n) and (e, f) reactions for which the data are currently available only for low energies…”
Get full text
Journal Article -
4
High sensitivity MOSFET-based neutron dosimetry
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-09-2010)“…A new dosemeter based on a metal-oxide-semiconductor field effect transistor sensitive to both neutrons and gamma radiation was manufactured at LAAS-CNRS…”
Get full text
Journal Article -
5
Non-linearity of recoil pulse height events in He-3 tubes
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-06-2010)“…Regarding neutron spectrometry, energy calibration of a He-3 counter was performed for neutron energies up to about 7 MeV, for various operating voltages in…”
Get full text
Journal Article -
6
MOSFET with a boron-loaded gate as a low-energy neutron dosimeter
Published in Radiation physics and chemistry (Oxford, England : 1993) (01-12-2011)“…A MOSFET-based low-energy neutron dosimeter has been fabricated using a 10B loaded gate electrode as ( n, α) converter. The response to thermal neutrons has…”
Get full text
Journal Article -
7
Thermal neutron dosimetry using MOSFET dosemeters
Published in Radiation measurements (01-10-2009)“…Metal-Oxide-Semiconductor Field Effect Transistors (MOSFETs) with a LiF powder placed on their surface were used as neutron dosemeter. The effect of thermal…”
Get full text
Journal Article Conference Proceeding -
8
Indirect measurement of inelastic cross section of relativistic protons in Pb target
Published in Annals of nuclear energy (01-07-2010)“…The inelastic cross section of relativistic protons in Pb was determined indirectly by measuring the neutron distribution along a Lead spallation neutron…”
Get full text
Journal Article -
9
Dose measurements around spallation neutron sources
Published in Radiation protection dosimetry (01-12-2008)“…Neutron dose measurements and calculations around spallation sources appear to be of great importance in shielding research. Two spallation sources were…”
Get full text
Journal Article -
10
Neutron measurements by passive methods in the Dubna transmutation assemblies
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-03-2004)“…In the general case of neutron measurement by passive detectors, the conversion of direct experimental data to neutron flux results by using (1) a…”
Get full text
Journal Article -
11
A neutron dosemeter based on a stack of two p-MOSFETs
Published in 2010 IEEE International Conference on Imaging Systems and Techniques (01-07-2010)“…The dosimetric characteristics of a new type of Metal-Oxide-Semiconductor field effect transistor (MOSFET), sensitive to both thermal and intermediate-fast…”
Get full text
Conference Proceeding -
12
Spallation neutron production in the new Dubna transmutation assembly
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-08-2003)“…A large Pb target with a U blanket was irradiated with 1.5 GeV protons at the Dubna Nuclotron accelerator. Solid-state nuclear track detectors measured neutron…”
Get full text
Journal Article -
13
Detection of spallation neutrons and protons using the (nat)Cd activation technique in transmutation experiments at Dubna
Published in Applied radiation and isotopes (01-07-2006)“…Various spallation sources have been used to transmute long-lived radioactive waste, mostly making use of the wide energy neutron fluence. In addition to…”
Get full text
Journal Article -
14
On the behavior of spallation neutrons from extended Pb targets plus moderator: A comparison between SSNTD measurements and calculation
Published in Radiation Measurements (01-11-2005)“…Thick Pb targets of different lengths were irradiated by 1 GeV protons at the Nuclotron accelerator of the High Energy Laboratory, JINR, Dubna. To favor…”
Get full text
Journal Article Conference Proceeding -
15
Neutron yields from massive lead and uranium targets irradiated with relativistic protons
Published in Radiation Measurements (2005)“…Long-lived isotopes can be transmuted into stable or short-lived elements either by neutron captures or neutron induced fission. The need of a large excess of…”
Get full text
Journal Article Conference Proceeding -
16
Application of activation methods on the Dubna experimental transmutation set-ups
Published in Applied radiation and isotopes (01-02-2003)“…High spallation neutron fluxes were produced by irradiating massive heavy targets with proton beams in the GeV range. The experiments were performed at the…”
Get full text
Journal Article -
17
Application of passive methods for electron flux measurements regarding to .sup.238U electron-disintegration studies
Published in Journal of radioanalytical and nuclear chemistry (01-08-2018)“…The electron flux is measured using .sup.238U targets detecting the (e, n) and (e, f) reactions for which the data are currently available only for low…”
Get full text
Journal Article -
18
-
19
Hadron multiplicity studies on a combined Pb/U-blanket spallation source: Experimental and simulation benchmark analysis
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-02-2009)“…Spallation sources are able to produce intense neutron fluxes using massive targets when irradiated by relativistic proton beams. Such sub-critical Accelerator…”
Get full text
Journal Article -
20
Preliminary results on neutron production from a Pb/U target irradiated by deuteron beam at 1.25 GeV/amu
Published in Radiation measurements (01-08-2008)“…A spallation neutron source consisted of a cylindrical Pb target and surrounded by uranium blanket was irradiated by deuteron beam 1.25 GeV/amu provided from…”
Get full text
Journal Article