Search Results - "Foo, Jong Yong A"
-
1
Phonocardiographic signal analysis method using a modified hidden Markov model
Published in Annals of biomedical engineering (01-03-2007)“…Auscultation is an important diagnostic indicator for cardiovascular analysis. Heart sound classification and analysis play an important role in the…”
Get full text
Journal Article -
2
A computational system to optimise noise rejection in photoplethysmography signals during motion or poor perfusion states
Published in Medical & biological engineering & computing (01-03-2006)“…Photoplethysmography (PPG) signals can be used in clinical assessment such as heart rate (HR) estimations and extraction of arterial flow waveforms. Motion…”
Get full text
Journal Article -
3
Use of pulse transit time to distinguish respiratory events from tidal breathing in sleeping children
Published in Chest (01-10-2005)“…Currently, esophageal pressure monitoring is the "gold standard" measure for inspiratory efforts, but its invasive nature necessitates a better tolerated and…”
Get more information
Journal Article -
4
Factors that Affect Pulse Wave Time Transmission in the Monitoring of Cardiovascular System
Published in Journal of clinical monitoring and computing (01-04-2008)“…Objectives Vascular transit time (VTT) can be defined as the first heart sound of the phonocardiography (PCG) signal to its arrival at the photoplethysmography…”
Get full text
Journal Article -
5
Predictive regression equations and clinical uses of peripheral pulse timing characteristics in children
Published in Physiological measurement (01-06-2005)“…Studies have shown that increased arterial stiffening can be an indication of cardiovascular diseases like hypertension. In clinical practice, this can be…”
Get more information
Journal Article -
6
Investigation of Pulse Transit Time Characteristics During Single and Recurrent Obstructive Respiratory Events
Published in Journal of clinical monitoring and computing (01-08-2008)“…Conventional overnight polysomnography (PSG) used to determine the respiratory behaviour during sleep can be a complex and expensive procedure. Pulse transit…”
Get full text
Journal Article -
7
Pulse transit time in paediatric respiratory sleep studies
Published in Medical engineering & physics (01-01-2007)“…Abstract Pulse transit time (PTT) has emerged over the recent decades as a simple and non-invasive measure to quantify inspiratory effort changes in adults…”
Get full text
Journal Article -
8
Estimation of breathing interval from the photoplethysmographic signals in children
Published in Physiological measurement (01-12-2005)“…Two important parameters that are generally under continual observation during clinical monitoring are heart rate (HR) variability and breathing interval (BI)…”
Get more information
Journal Article -
9
Screening of obstructive and central apnoea/hypopnoea in children using variability : A preliminary study
Published in Acta pædiatrica (Oslo) (01-05-2006)“…Polysomnography (PSG) is the current standard protocol for sleep disordered breathing (SDB) investigation in children. Presently, there are limited reliable…”
Get full text
Journal Article -
10
Pulse transit time changes observed with different limb positions
Published in Physiological measurement (01-12-2005)“…Pulse transit time (PTT) is a non-invasive measure of arterial compliance. It can be used to assess instantaneous blood pressure (BP) changes in continual…”
Get more information
Journal Article -
11
Variability in time delay between two models of pulse oximeters for deriving the photoplethysmographic signals
Published in Physiological measurement (01-08-2005)“…Pulse oximetry is commonly used as an arterial blood oxygen saturation (SaO2) measure. However, its other serial output, the photoplethysmography (PPG) signal,…”
Get more information
Journal Article -
12
Effect of ethnicity and growth on ratio-based transit time surrogate ankle-brachial index marker from a Chinese children's perception
Published in Acta Cardiologica (01-06-2008)“…Objective - Since its introduction, ankle brachial index (ABI) measurements have been used in numerous clinical studies for its diagnostic and epidemiological…”
Get full text
Journal Article -
13
Effects of poorly perfused peripheries on derived transit time parameters of the lower and upper limbs
Published in Biomedizinische Technik (01-06-2008)“…A simple and non-intrusive approach termed the pulse transit time ratio (PTTR) has recently been shown to be a potential surrogate of the ankle-brachial index…”
Get more information
Journal Article -
14
Comparison of wavelet transformation and adaptive filtering in restoring artefact-induced time-related measurement
Published in Biomedical signal processing and control (2006)“…Photoplethysmography (PPG) can be used in time-related measurements such as heart rate (HR) and pulse transit time (PTT) estimations in the medical fields. The…”
Get full text
Journal Article -
15
Screening of obstructive and central apnoea/hypopnoea in children using variability: A preliminary study
Published in Acta Paediatrica (01-05-2006)“…Aim: Polysomnography (PSG) is the current standard protocol for sleep disordered breathing (SDB) investigation in children. Presently, there are limited…”
Get full text
Journal Article