Search Results - "Folks, Russell"

Refine Results
  1. 1

    Novel solid-state-detector dedicated cardiac camera for fast myocardial perfusion imaging: multicenter comparison with standard dual detector cameras by Esteves, Fabio P., Raggi, Paolo, Folks, Russell D., Keidar, Zohar, Wells Askew, J., Rispler, Shmuel, O’Connor, Michael K., Verdes, Liudmilla, Garcia, Ernest V.

    Published in Journal of nuclear cardiology (01-12-2009)
    “…Objective To compare the diagnostic performance of a new dedicated ultrafast solid-state cardiac camera (Discovery NM 530c [DNM]) with standard dual detector…”
    Get full text
    Journal Article
  2. 2

    Diagnostic performance of low-dose rest/stress Tc-99m tetrofosmin myocardial perfusion SPECT using the 530c CZT camera: Quantitative vs visual analysis by Esteves, Fabio P., Galt, James R., Folks, Russell D., Verdes, Liudmila, Garcia, Ernest V.

    Published in Journal of nuclear cardiology (01-02-2014)
    “…We set out to develop normal databases and prospectively validate abnormality criteria for a low-dose Tc-99m tetrofosmin myocardial perfusion SPECT protocol…”
    Get full text
    Journal Article
  3. 3

    Computer assisted interpretation of Tc-99m mercaptoacetyltriglycine diuretic scintigraphy enhances resident performance by Taylor, Andrew T., Fazlur Rahman, A.K.M., Folks, Russell D., Moncayo, Valeria, Savir-Baruch, Bital, Plaxton, Nicholas, Polsani, Aruna, Halkar, Raghuveer K., Dubovsky, Eva V., Garcia, Ernest V., Manatunga, Amita

    Published in Nuclear medicine communications (01-06-2023)
    “…iRENEX is a software module that incorporates scintigraphic and clinical data to interpret 99m Tc- mercaptoacetyltriglycine (MAG3) diuretic studies and provide…”
    Get full text
    Journal Article
  4. 4
  5. 5
  6. 6

    Repeatability of left ventricular dyssynchrony and function parameters in serial gated myocardial perfusion SPECT studies by Lin, Xianhe, Xu, Huiqin, Zhao, Xuefeng, Folks, Russell D., Garcia, Ernest V., Soman, Prem, Chen, Ji

    Published in Journal of nuclear cardiology (01-10-2010)
    “…Background The purpose of this study was to establish the repeatability of left-ventricular (LV) dyssynchrony and function parameters measured from serial…”
    Get full text
    Journal Article
  7. 7

    The increasing role of quantification in clinical nuclear cardiology: The Emory approach by Garcia, Ernest V., Faber, Tracy L., Cooke, C. David, Folks, Russell D., Chen, Ji, Santana, Cesar

    Published in Journal of nuclear cardiology (01-07-2007)
    “…Single photon emission computed tomography (SPECT) myocardial perfusion imaging has attained widespread clinical acceptance as a standard of care for patients…”
    Get full text
    Journal Article
  8. 8
  9. 9
  10. 10
  11. 11

    I-123 mIBG and Tc-99m myocardial SPECT imaging to predict inducibility of ventricular arrhythmia on electrophysiology testing: A retrospective analysis by Zhou, Yanli, Zhou, Weihua, Folks, Russell D., Manatunga, Daya N., Jacobson, Arnold F., Bax, Jeroen J., Garcia, Ernest V., Chen, Ji

    Published in Journal of nuclear cardiology (01-10-2014)
    “…The purpose of this study is to assess mIBG uptake in scar border zone and its relation with ventricular arrhythmia (VA) inducibility on electrophysiology (EP)…”
    Get full text
    Journal Article
  12. 12

    99m Tc-MAG 3 : Image Wisely by Taylor, Andrew T, Folks, Russell D, Rahman, A K M Fazlur, Polsani, Aruna, Dubovsky, Eva V, Halkar, Raghuveer, Manatunga, Amita

    Published in Radiology (01-07-2017)
    “…Purpose To determine if commonly administered doses of technetium 99m ( Tc) mertiatide (MAG ) in the range of 300-370 MBq (approximately 8-10 mCi) contribute…”
    Get full text
    Journal Article
  13. 13

    99mTc-MAG3: Image Wisely by Taylor, Andrew T, Folks, Russell D, Rahman, A K M Fazlur, Polsani, Aruna, Dubovsky, Eva V, Halkar, Raghuveer, Manatunga, Amita

    Published in Radiology (01-07-2017)
    “…Purpose To determine if commonly administered doses of technetium 99m (99mTc) mertiatide (MAG3) in the range of 300-370 MBq (approximately 8-10 mCi) contribute…”
    Get full text
    Journal Article
  14. 14
  15. 15

    Quantitative I-123 mIBG SPECT in differentiating abnormal and normal mIBG myocardial uptake by Chen, Ji, Folks, Russell D., Verdes, Liudmila, Manatunga, Daya N., Jacobson, Arnold F., Garcia, Ernest V.

    Published in Journal of nuclear cardiology (01-02-2012)
    “…The purpose of this study was to evaluate global quantitation of cardiac uptake on I-123 mIBG SPECT. The study included a pilot group of 67 subjects and a…”
    Get full text
    Journal Article
  16. 16

    Quantitative (82)Rb PET/CT: development and validation of myocardial perfusion database by Santana, Cesar A, Folks, Russell D, Garcia, Ernest V, Verdes, Liudmila, Sanyal, Rupan, Hainer, Jon, Di Carli, Marcelo F, Esteves, Fabio P

    Published in The Journal of nuclear medicine (1978) (01-07-2007)
    “…The use of myocardial perfusion (82)Rb PET/CT studies continues to increase but its accuracy using database quantification methods for the diagnosis of…”
    Get full text
    Journal Article
  17. 17

    99mTc-MAG3 Renography: Normal Values for MAG3 Clearance and Curve Parameters, Excretory Parameters, and Residual Urine Volume by Esteves, Fabio P, Taylor, Andrew, Manatunga, Amita, Folks, Russell D, Krishnan, Meghna, Garcia, Ernest V

    Published in American journal of roentgenology (1976) (01-12-2006)
    “…Specific quantitative measurements have been recommended to assist in the interpretation of technetium-99m mercaptoacetyltriglycine (MAG3) renal studies. Our…”
    Get full text
    Journal Article
  18. 18
  19. 19
  20. 20