Search Results - "Florean, M"
-
1
Reutilization and stabilization of wastes by the production of glass foams
Published in Ceramics international (01-08-2007)“…Glass foams are known to represent highly valuable products for thermal and acoustic insulation, often produced by employing wastes. Although the usage of…”
Get full text
Journal Article -
2
IVVS actuating system compatibility test to ITER gamma radiation conditions
Published in Fusion engineering and design (01-10-2013)“…•ENEA developed and tested a prototype of a laser In Vessel Viewing and ranging System (IVVS) for ITER.•One piezo-motor prototype has been tested on the ENEA…”
Get full text
Journal Article -
3
Iter in vessel viewing system design and assessment activities
Published in Fusion engineering and design (01-10-2011)“…The In Vessel Viewing System (IVVS) is fundamental remote handling equipment, which will be used to make a survey of the status of the blanket first wall and…”
Get full text
Journal Article Conference Proceeding -
4
IDENTIFIKASI NILAI PENDIDIKAN KARAKTER DALAM PELAKSANAAN KEGIATAN EKSTRAKURIKULER DRUMBBAND
Published in EduHumaniora : jurnal pendidikan dasar (31-07-2020)“…Karakter merupakan sifat, watak, akhlak maupun kepribadian diri seseorang. Sekolah memiliki peranan memiliki peranan yang penting dalam pendidikan karakter,…”
Get full text
Journal Article -
5
Correction method of vibration effects for images produced by laser radar
Published in 2015 9th International Symposium on Image and Signal Processing and Analysis (ISPA) (01-09-2015)“…Present large scale fusion research reactors need imaging and metrology systems to make a survey of the status of the in-vessel plasma facing components in…”
Get full text
Conference Proceeding -
6
Monitoring methodology for TID damaging of SDRAM devices based on retention time analysis
Published in 19th IEEE International Symposium on Defect and Fault Tolerance in VLSI Systems, 2004. DFT 2004. Proceedings (2004)“…Total ionizing dose (TID) is a potential problem for solid state devices exposed to ionizing radiation. An important parameter to define is the level of TID…”
Get full text
Conference Proceeding -
7
TID test for SDRAM based IEEM calibration system
Published in IEEE Symposium Conference Record Nuclear Science 2004 (2004)“…Traditionally, to map out device sensitivity with submicrometric resolutions one uses a microbeam. Ion electron emission microscopy (IEEM) appears to be a…”
Get full text
Conference Proceeding -
8
FTU bolometer electronic system upgrade
Published in Fusion engineering and design (01-10-2013)“…► Design and realization of a new bolometer electronic system. ► Many improvements over the actual commercial system. ► Architecture based on digital…”
Get full text
Journal Article -
9
REUTILISATION AND STABILISATION OF WASTES BY THE PRODUCTION OF GLASS FOAMS
Published in Ceramics international (01-01-2007)“…A cellular structure was achieved after oxidation of SiC-based wastes from the polishing of glass articles. The foamed recycled soda-lime glass incorporated…”
Get full text
Journal Article -
10
Treatment of acute myeloid leukemia and myelodysplastic syndrome by low dose arabinosyl cytosine
Published in Haematologica (Roma) (01-01-1985)Get more information
Journal Article -
11
Side effects of d-penicillamine in the treatment of rheumatoid arthritis
Published in Minerva medica (31-05-1986)“…In the present study, the side effects of d-Penicillamine therapy in 54 patients with rheumatoid arthritis are analyzed. The therapeutic efficacy of the drug…”
Get more information
Journal Article