Search Results - "Flecher, X"
-
1
Lower limb length and offset in total hip arthroplasty
Published in Orthopaedics & traumatology, surgery & research (01-02-2016)“…Abstract Restoration of normal hip biomechanics is a key goal of total hip arthroplasty (THA) and favorably affects functional recovery. Furthermore, a major…”
Get full text
Journal Article -
2
Femoral offset: Anatomical concept, definition, assessment, implications for preoperative templating and hip arthroplasty
Published in Orthopaedics & traumatology, surgery & research (01-05-2009)“…Summary Background objective Femoral offset is supposed to influence the results of hip replacement but little is known about the accurate method of measure…”
Get full text
Journal Article -
3
Pre-operative function, motivation and duration of symptoms predict sporting participation after total hip replacement
Published in Journal of bone and joint surgery. British volume (01-08-2014)“…There is little in the literature on the level of participation in sports which patients undertake after total hip replacement (THR). Our aims in this study…”
Get full text
Journal Article -
4
Can three-dimensional patient-specific cutting guides be used to achieve optimal correction for high tibial osteotomy? Pilot study
Published in Orthopaedics & traumatology, surgery & research (01-04-2017)“…Abstract Introduction Treatment of medial tibiofemoral osteoarthritis with a high-tibial osteotomy (HTO) is most effective when the optimal angular correction…”
Get full text
Journal Article -
5
Posterior tibial slope changes after opening- and closing-wedge high tibial osteotomy: A comparative prospective multicenter study
Published in Orthopaedics & traumatology, surgery & research (01-02-2012)“…Summary Introduction Valgus high tibial osteotomy is considered to be an effective treatment for unicompartmental medial osteoarthritis. It is generally…”
Get full text
Journal Article -
6
Endoscopic or arthroscopic iliopsoas tenotomy for iliopsoas impingement following total hip replacement. A prospective multicenter 64-case series
Published in Orthopaedics & traumatology, surgery & research (01-12-2017)“…Impingement between the acetabular component and the iliopsoas tendon is a cause of anterior pain after total hip replacement (THR). Treatment can be…”
Get full text
Journal Article -
7
Influence of treatment modality on morbidity and mortality in periprosthetic femoral fracture. A comparative study of 71 fractures treated by internal fixation or femoral implant revision
Published in Orthopaedics & traumatology, surgery & research (01-05-2018)“…The incidence of periprosthetic femoral fracture is constantly increasing, with high associated morbidity and mortality. Surgical treatment is guided by the…”
Get full text
Journal Article -
8
From radiographs to 3D printing: how can new surgical planning technologies contribute to hip surgery?
Published in Orthopaedics & traumatology, surgery & research (01-05-2017)Get full text
Journal Article -
9
Epidemiology of distal femur fractures in France in 2011–12
Published in Orthopaedics & traumatology, surgery & research (01-09-2014)“…Abstract Introduction Epidemiological study of femoral fractures has been dominated by proximal fractures. Distal fracture requires equal attention for correct…”
Get full text
Journal Article -
10
Pelvic fracture in multiple trauma: A 67-case series
Published in Orthopaedics & traumatology, surgery & research (01-12-2016)“…Abstract Introduction Severe pelvic trauma remains associated with elevated mortality, largely due to hemorrhagic shock. Objective The main study objective was…”
Get full text
Journal Article -
11
Relation between lower extremity alignment and proximal femur anatomy. Parameters during total hip arthroplasty
Published in Orthopaedics & traumatology, surgery & research (01-09-2013)“…Summary Background Lower extremity alignment correlates with native femoral offset. Eventual impact of the change in femoral offset induced by total hip…”
Get full text
Journal Article -
12
Titanium-titanium modular neck for primary THA. Result of a prospective series of 170 cemented THA with a minimum follow-up of 5 years
Published in Orthopaedics & traumatology, surgery & research (01-04-2015)“…Abstract Background Although they have been in use since the end of the 1980s, modular titanium neck components are associated with a risk of wear or fracture,…”
Get full text
Journal Article -
13
Blade-plate fixation for distal femoral fractures: A case-control study
Published in Orthopaedics & traumatology, surgery & research (01-09-2014)“…Abstract Background The blade-plate is the earliest of the contemporary internal fixation devices introduced for distal femoral fractures. The recent…”
Get full text
Journal Article -
14
Is a hip distractor useful in the arthroscopic treatment of femoroacetabular impingement?
Published in Orthopaedics & traumatology, surgery & research (01-06-2011)“…Summary Introduction There is increasing interest in using hip arthroscopy for the treatment of femoroacetabular impingement (FAI). However, the distraction is…”
Get full text
Journal Article -
15
Comparison of the inter- and intra-observer reproducibility of the Crowe, Hartofilakidis and modified Cochin classification systems for the diagnosis of developmental dysplasia of the hip
Published in Orthopaedics & traumatology, surgery & research (01-10-2014)“…Abstract Introduction Developmental dysplasia of the hip (DDH) leads to multiple treatment challenges during adulthood. Surgical treatment is mainly based on…”
Get full text
Journal Article -
16
Garden I femoral neck fractures in patients 65 years old and older: Is conservative functional treatment a viable option?
Published in Orthopaedics & traumatology, surgery & research (01-05-2010)“…Summary Introduction Internal fixation is the preferred treatment of Garden I femoral neck fractures in the elderly. High re-operation rates have however been…”
Get full text
Journal Article -
17
Do tantalum components provide adequate primary fixation in all acetabular revisions?
Published in Orthopaedics & traumatology, surgery & research (01-05-2010)“…Summary Introduction A number of studies have reported favorable results of cementless fixation in acetabular revisions. Nevertheless, the implant bearing on…”
Get full text
Journal Article -
18
Design parameters dependences on contact stress distribution in gait and jogging phases after total hip arthroplasty
Published in Journal of biomechanics (01-01-2008)“…Abstract We have developed a mathematical model to calculate the contact stress distribution in total hip arthroplasty (THA) prosthesis between the…”
Get full text
Journal Article -
19
Antibiotic-loaded tantalum may serve as an antimicrobial delivery agent
Published in Journal of bone and joint surgery. British volume (01-07-2019)“…AimsThe aims of this study were to compare the mean duration of antibiotic release and the mean zone of inhibition between vancomycin-loaded porous tantalum…”
Get full text
Journal Article -
20
Three-dimensional anatomy of the hip in osteoarthritis after developmental dysplasia
Published in Journal of bone and joint surgery. British volume (01-09-2005)“…Using radiography and computer tomography (CT) we studied the morphology of 83 hips in 69 Caucasian adults with osteoarthritis secondary to developmental…”
Get full text
Journal Article