Search Results - "Flanz, Jay"
-
1
Reassessment of the Necessity of the Proton Gantry: Analysis of Beam Orientations From 4332 Treatments at the Massachusetts General Hospital Proton Center Over the Past 10 Years
Published in International journal of radiation oncology, biology, physics (01-05-2016)“…Purpose To retrospectively analyze the beam approaches used in gantry-based proton treatments, and to reassess the practical advantages of the gantry, compared…”
Get full text
Journal Article -
2
Assessment of out-of-field absorbed dose and equivalent dose in proton fields
Published in Medical physics (Lancaster) (01-01-2010)“…Purpose: In proton therapy, as in other forms of radiation therapy, scattered and secondary particles produce undesired dose outside the target volume that may…”
Get full text
Journal Article -
3
Out-of-Field Dose Equivalents Delivered by Passively Scattered Therapeutic Proton Beams for Clinically Relevant Field Configurations
Published in International journal of radiation oncology, biology, physics (2009)“…Purpose Microdosimetric measurements were performed at Massachusetts General Hospital, Boston, MA, to assess the dose equivalent external to passively…”
Get full text
Journal Article -
4
A respiratory-gated treatment system for proton therapy
Published in Medical physics (Lancaster) (01-08-2007)“…Proton therapy offers the potential for excellent dose conformity and reduction in integral dose. The superior dose distribution is, however, much more…”
Get full text
Journal Article -
5
Charged particle beams to cure cancer: Strengths and challenges
Published in Seminars in oncology (01-06-2019)“…Charged particle therapy is the most advanced radiotherapy method in oncology. The favorable depth-dose distribution and the biological properties of charged…”
Get full text
Journal Article -
6
Technical note: Does the greater power of pencil beam scanning reduce the need for a proton gantry? A study of head‐and‐neck and brain tumors
Published in Medical physics (Lancaster) (01-02-2022)“…Purpose Proton therapy systems without a gantry can be more compact and less expensive in terms of capital cost and therefore more available to a larger…”
Get full text
Journal Article -
7
Investigation of real tissue water equivalent path lengths using an efficient dose extinction method
Published in Physics in medicine & biology (23-06-2017)“…For proton therapy, an accurate conversion of CT HU to relative stopping power (RSP) is essential. Validation of the conversion based on real tissue samples is…”
Get more information
Journal Article -
8
Future (of) Synchrotrons for Particle Therapy
Published 24-04-2018“…CERN Yellow Report CERN-2017-004-SP pp. 293-307 The field of particle therapy is quickly growing and yet it's more widespread adoption is limited by size, cost…”
Get full text
Journal Article -
9
Assessment of out-of-field absorbed dose and equivalent dosein proton fields
Published in Medical physics (Lancaster) (15-12-2009)“…Purpose: In proton therapy, as in other forms of radiation therapy, scattered and secondary particles produce undesired dose outside the target volume that may…”
Get full text
Journal Article -
10
Sensitivities in the production of spread-out Bragg peak dose distributions by passive scattering with beam current modulation
Published in Medical physics (Lancaster) (01-10-2007)“…A spread-out Bragg peak (SOBP) is used in proton beam therapy to create a longitudinal conformality of the required dose to the target. In order to create this…”
Get full text
Journal Article -
11
A soft robotic device for patient immobilization in sitting and reclined positions for a compact proton therapy system
Published in 2020 8th IEEE RAS/EMBS International Conference for Biomedical Robotics and Biomechatronics (BioRob) (01-11-2020)“…Proton therapy has a substantial physical advantage over conventional cancer radiation treatment with X-rays. Proton therapy reduces the radiation dose to…”
Get full text
Conference Proceeding -
12
Does the greater power of pencil beam scanning reduce the need for a proton gantry? A study of head-and-neck and brain tumors
Published 26-06-2022“…Medical Physics, 49(2), 813-824, 2022 Proton therapy systems without a gantry can be more compact and less expensive in terms of capital cost, and therefore…”
Get full text
Journal Article -
13
Critical feature analysis of a radiotherapy machine
Published in Reliability engineering & system safety (01-07-2005)“…The software implementation of the emergency shutdown feature in a major radiotherapy system was analyzed, using a directed form of code review based on module…”
Get full text
Journal Article Conference Proceeding -
14
OUT-OF-FIELD DOSE EQUIVALENTS DELIVERED BY PASSIVELY SCATTERED THERAPEUTIC PROTON BEAMS FOR CLINICALLY RELEVANT FIELD CONFIGURATIONS
Published in Australasian physical & engineering sciences in medicine (01-12-2008)“…Dose equivalent values ranged from 8.8-0.3 mSv/Gy (2.5-60 cm lateral displacement) for a typical prostate cancer field, 10.8-0.58 mSv/Gy (2.5-40 cm lateral…”
Get full text
Journal Article -
15
DETERMINATION OF THE DOSE EQUIVALENT NEAR PROTON PENCIL BEAMS
Published in Australasian physical & engineering sciences in medicine (01-12-2008)“…Information from the spectra of energy deposition events allows one to determine the average quality factor using established microdosimetric methods and the…”
Get full text
Journal Article