Search Results - "Flannery, Anthony F"

  • Showing 1 - 4 results of 4
Refine Results
  1. 1

    Field Evaluation of an Electrochemical Probe for in Situ Screening of Heavy Metals in Groundwater by Herdan, Janet, Feeney, Rosemary, Kounaves, Samuel P, Flannery, Anthony F, Storment, Christopher W, Kovacs, Gregory T. A, Darling, R. Bruce

    Published in Environmental science & technology (01-01-1998)
    “…The use of an electrochemically based probe for in situ determination of heavy metals in groundwater is described. The in situ probe, consisting of a…”
    Get full text
    Journal Article
  2. 2

    Microfabricated electrochemical analysis system for heavy metal detection by Reay, Richard J., Flannery, Anthony F., Storment, Christopher W., Kounaves, Samuel P., Kovacs, Gregory T.A.

    Published in Sensors and actuators. B, Chemical (01-08-1996)
    “…A low power, hand-held system has been developed for the measurement of heavy metal ions in aqueous solutions. The system consists of an electrode array…”
    Get full text
    Journal Article Conference Proceeding
  3. 3

    Fabrication Methods for Environmentally Hardened Sensors by Flannery, Anthony F

    Published 01-01-2011
    “…Micromachined sensors have continued to open exciting new doors in metrology. Applications in biology, pharmacology, genetics, chemistry, and other fields are…”
    Get full text
    Dissertation
  4. 4

    PECVD silicon carbide as a chemically resistant material for micromachined transducers by Flannery, Anthony F., Mourlas, Nicholas J., Storment, Christopher W., Tsai, Stan, Tan, Samantha H., Heck, John, Monk, Dave, Kim, Thomas, Gogoi, Bishnu, Kovacs, Gregory T.A.

    Published in Sensors and actuators. A. Physical. (01-10-1998)
    “…Plasma enhanced chemical vapor deposited (PECVD) amorphous hydrogenated silicon carbide is a material with many potential applications for micromachined…”
    Get full text
    Journal Article