Chimera: a project of a 4π detector for heavy ion reactions studies at intermediate energy
Published in Nuclear physics. A (06-02-1995)Get full text
Journal Article -
2
Light response and particle identification with large CsI(TI) crystals coupled to photodiodes
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-01-1996)“…The light response of large CsI(TI) crystals supplied by various companies and coupled to photodiodes has been investigated. Energy resolution measurements and…”
Get full text
Journal Article -
3
Timing performances and edge effects of detectors worked from 6-in. silicon slices
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-01-1997)“…Prototypes of new passivated implanted planar silicon detectors, obtained for the first time from 6 in. silicon slices, have been tested. The time and energy…”
Get full text
Journal Article -
4
Detector array control and triggering
Published in IEEE transactions on nuclear science (01-08-1998)“…A commercial DSP-based board installed in a host-PC was employed for the fast, on-line and real-time computation of special algorithms, in order to perform…”
Get full text
Journal Article -
5
Physics with the Chimera detector at LNS in Catania: the REVERSE experiment
Published in Nuclear Physics A (29-01-2001)Get full text
Journal Article Conference Proceeding -
6
Multifragmentation threshold in $^{93}Nb+${nat}Mg collisions at 30 MeV/nucleon
Published in Nuclear physics. A (01-10-2008)“…We analyzed the $^{93}Nb$ on $^{nat}Mg$ reaction at $30$ MeV/nucleon in the aim of disentangling binary sequential decay and multifragmentation decay close to…”
Get full text
Journal Article -
7
Facilities at LNS for charge and mass identification of heavy-ion reaction products
Published in Il Nuovo cimento, A (01-02-1991)Get full text
Journal Article -
8
Review of Instruments Used in Hazard Vulnerability Analysis of Hospitals
Published in Prehospital and disaster medicine (01-04-2017)Get full text
Journal Article -
9
Hazard Vulnerability Analysis: Practices in Massachusetts Hospitals
Published in Prehospital and disaster medicine (01-04-2017)Get full text
Journal Article -
10
Hazard Vulnerability Analysis: Practices in Boston Hospitals
Published in Prehospital and disaster medicine (01-04-2017)Get full text
Journal Article -
11
Data acquisition and real-time computing by a DSP-based system
Published in Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms (01-03-1998)“…A digital signal processor (DSP) based two-parameter data acquisition system, connected to two analog-to-digital converters (ADCs) by means of an ad hoc built…”
Get full text
Journal Article -
12
The enhanced data acquisition system for the 4 pi detector CHIMERA
Published in IEEE transactions on nuclear science (01-04-2000)“…CHIMERA is a second generation 4 pi detector for high resolution light particle and fragment measurements in the field of intermediate energy nuclear…”
Get full text
Journal Article -
13
The on-line computational and control system for the 4 pi -detector CHIMERA
Published in IEEE transactions on nuclear science (01-04-2000)“…A commercial two-DSP-based board is the basic unit of the on-line computational and control system under development for the multidetector array CHIMERA. The…”
Get full text
Journal Article -
14
The on-line Computational and Control System for the 4pi-Detector CHIMERA
Published in IEEE transactions on nuclear science (01-04-2000)“…A commercial two-DSP (Digital Signal Processor)-based board is the basic unit of the on-line computational and control system under development for the CHIMERA…”
Get full text
Journal Article -
15
The enhanced data acquisition system for the 4[pi] detector CHIMERA
Published in IEEE transactions on nuclear science (01-04-2000)“…An enhanced data acquisition, control and trigger system has been developed to manage the almost 5000 electronic channels of the detector…”
Get full text
Journal Article -
16
The on-line computational and control system for the 4[pi]-detector CHIMERA
Published in IEEE transactions on nuclear science (01-04-2000)“…The physical data, collected and organized in UDP packets by the data acquisition system, are read through a 10 Mbit/s Ethernet network…”
Get full text
Journal Article -
17
The on-line computational and control system for the 4/spl pi/-detector CHIMERA
Published in IEEE transactions on nuclear science (01-04-2000)“…A commercial two-DSP-based board is the basic unit of the on-line computational and control system under development for the multidetector array CHIMERA. The…”
Get full text
Journal Article -
18
The enhanced data acquisition system for the 4pi detector CHIMERA
Published in IEEE transactions on nuclear science (01-04-2000)“…CHIMERA is a second generation 4pi detector for high-resolution light particle and fragment measurements in the field of intermediate energy nuclear reactions…”
Get full text
Journal Article -
19
The enhanced data acquisition system for the 4/spl pi/ detector CHIMERA
Published in IEEE transactions on nuclear science (01-04-2000)“…CHIMERA is a second generation 4/spl pi/ detector for high resolution light particle and fragment measurements in the field of intermediate energy nuclear…”
Get full text
Journal Article -
20
The data acquisition and control system for the 4pi detector CHIMERA
Published in IEEE transactions on nuclear science (01-08-1998)“…CHIMERA (Charged Heavy Ions Mass and Energy Resolving Array), a new 4pi detector for charged particles is under development at various sites of the Istituto…”
Get full text