Search Results - "Feist, J. H."

Refine Results
  1. 1

    Experience with the commissioning of the superconducting stellarator Wendelstein 7-X by Bosch, Hans-Stephan, Bykov, V., Brakel, R., van Eeten, P., Feist, J.-H., Gasparotto, M., Grote, H., Klinger, T., Nagel, M., Naujoks, D., Neilson, G.H., Rummel, T., Schacht, J., Vilbrandt, R., Wegener, L., Werner, A.

    Published in Fusion engineering and design (01-10-2015)
    “…•Present status of W7-X assembly.•Preparation of commissioning.•Recent results of commission.•Further step in the commissioning of W7-X.•Lessens learned. The…”
    Get full text
    Journal Article
  2. 2

    Quality management for WENDELSTEIN 7-X—Lessons learned by Feist, J.-H., Bramow, H.-J., Brockmann, R., Gliege, G., Grünberg, D., Kluck, T., Pohle, D., Schroeder, M., Schult, R., Vilbrandt, R.

    Published in Fusion engineering and design (01-10-2007)
    “…The WENDELSTEIN 7-X stellarator is the next step device in the stellarator line of IPP Garching. It is being assembled in the branch institute of IPP at…”
    Get full text
    Journal Article Conference Proceeding
  3. 3

    Progress in the Design, Manufacture and Testing of the W7-X Superconducting Magnets by Sborchia, C., Baldzuhn, J., Feist, J.H., Risse, K., Rummel, T., Viebke, H., Wanner, M.

    “…The W7-X machine is a low-shear stellarator of the Wendelstein line being assembled in Greifswald, Germany. The manufacture of its superconducting magnets is…”
    Get full text
    Journal Article Conference Proceeding
  4. 4

    Rf ion sources for fusion applications: design, development and performance by Speth, E, Ciric, M, Feist, J.H, Frank, P, Heinemann, B, Kraus, W, Probst, F, Riedl, R, Trainham, R, Vollmer, O, Wilhelm, R

    Published in Fusion engineering and design (01-11-1999)
    “…The use of rf ion sources in neutral beam injection (NBI) systems offers reduced maintenance and cost due to the absence of filaments. For the first time…”
    Get full text
    Journal Article Conference Proceeding
  5. 5

    Digital radiography and conventional imaging of the chest: a comparison of observer performance by Thaete, FL, Fuhrman, CR, Oliver, JH, Britton, CA, Campbell, WL, Feist, JH, Straub, WH, Davis, PL, Plunkett, MB

    Published in American journal of roentgenology (1976) (01-03-1994)
    “…The purpose of this study was to compare observer performance in interpreting high-quality, digitally acquired computed radiographs of the chest displayed on…”
    Get full text
    Journal Article Conference Proceeding
  6. 6

    Final design and construction of the Wendelstein7-X coils by Wegener, L, Feist, J.-H, Sapper, J, Kerl, F, Werner, F

    Published in Fusion engineering and design (01-11-2001)
    “…The Stellarator of the Wendelstein 7-X (W7-X) experiment contains a system of 50 non-planar and 20 planar superconducting coils. The coils were designed by the…”
    Get full text
    Journal Article Conference Proceeding
  7. 7

    Design and construction of WENDELSTEIN 7-X by Wanner, M, Feist, J.-H, Renner, H, Sapper, J, Schauer, F, Schneider, H, Erckmann, V, Niedermeyer, H

    Published in Fusion engineering and design (01-10-2001)
    “…Following the approval by EURATOM and the German government WENDELSTEIN 7-X (W7-X) is presently the largest fusion project under construction. W7-X is a…”
    Get full text
    Journal Article Conference Proceeding
  8. 8

    Assembly and test of the W7-X demo-cryostat by Schauer, F., Bau, H., Bojko, I., Brockmann, R., Feist, J.-H., Hein, B., Pieger-Frey, M., Pirsch, H., Sapper, J., Sombach, B., Stadlbauer, J., Volzke, O., Wald, I., Wanner, M.

    Published in Fusion engineering and design (01-10-2001)
    “…An overview is given on the status of the demo-cryostat project for the WENDELSTEIN 7-X stellarator. Construction and assembly of the prototype are finished,…”
    Get full text
    Journal Article Conference Proceeding
  9. 9

    Quality management for WENDELSTEIN 7-X by Feist, J.-H, Bramow, H.-J, Bräuer, T, Gliege, G, Kamionka, U, Krause, B, Pieger-Frey, M, Wanner, M

    Published in Fusion engineering and design (01-11-2001)
    “…The WENDELSTEIN 7-X stellarator is the next step device in the stellarator line of IPP Garching and is being built in the new branch institute of IPP at…”
    Get full text
    Journal Article Conference Proceeding
  10. 10
  11. 11

    Storage phosphor radiographs vs conventional films: interpreters' perceptions of diagnostic quality by Fuhrman, CR, Gur, D, Good, B, Rockette, H, Cooperstein, LA, Feist, JH

    Published in American journal of roentgenology (1976) (01-05-1988)
    “…We compared storage phosphor images with high-quality conventional film-screen images by evaluating physicians' perceptions of image quality and their levels…”
    Get full text
    Journal Article
  12. 12

    Acquired tracheomalacia: etiology and differential diagnosis by Feist, J H, Johnson, T H, Wilson, R J

    Published in Chest (01-09-1975)
    “…The noninvasive diagnosis of impaired mechanical integrity or compliance of the trachea is most accurately made by fluoroscopic observation recorded on video…”
    Get more information
    Journal Article
  13. 13

    Extra- and intrasplenic artery aneurysms in portal hypertension by Feist, J H, Gajaraj, A

    Published in Radiology (01-11-1977)
    “…Extra- and intrasplenic arterial aneurysms have occasionally been encountered in cases of portal hypertension both with and without cirrhosis. The exact…”
    Get more information
    Journal Article
  14. 14

    Asbestosis among electricians by Hodgson, M J, Parkinson, D K, Sabo, S, Owens, G R, Feist, J H

    Published in Journal of occupational medicine (01-08-1988)
    “…In a cross-sectional study of a small group of non-shipyard electricians, the prevalence of asbestosis, defined as irregular opacities of at least 1/0…”
    Get more information
    Journal Article
  15. 15
  16. 16
  17. 17
  18. 18
  19. 19
  20. 20