Search Results - "Ezzell, G"
-
1
WE‐E‐141‐02: An Improvement in IMRT QA Results and Beam Matching in LINACs Using Statistical Process Control
Published in Medical Physics (01-06-2013)“…Purpose: The purpose of this study is to apply the principles of Statistical Process Control (SPC) in the context of patient specific IMRT QA to set clinic…”
Get full text
Conference Proceeding Journal Article -
2
WE‐F‐WAB‐01: Safety Improvement Through Incident Learning
Published in Medical Physics (01-06-2013)“…Incident learning is a key tool for improving the quality and safety of procedures. Its use has been linked to better patient‐safety outcomes. This session is…”
Get full text
Conference Proceeding Journal Article -
3
Nine-year Outcome and Toxicity in Patients Treated With IMRT for Clinically Localized Prostate Cancer
Published in International journal of radiation oncology, biology, physics (01-11-2012)Get full text
Journal Article -
4
WE‐E‐500‐01: Physics Pheud
Published in Medical Physics (01-06-2013)“…Come on down! This symposium adopts the format and excitement of a television game show to highlight important and contemporary issues in the science,…”
Get full text
Conference Proceeding Journal Article -
5
TH‐B‐BRC‐01: Tools for IMRT Commissioning: Static and Rotating Gantries
Published in Medical Physics (01-06-2009)“…Commissioning an IMRT system refers to the initial verification by phantom studies that treatments can be planned, prepared, and delivered with sufficient…”
Get full text
Conference Proceeding Journal Article -
6
-
7
WE‐A‐AUD C‐01: IMRT Commissioning: A Multi‐Center Evaluation of a Standardized Test Protocol
Published in Medical Physics (01-06-2008)“…There is evidence that IMRT treatments may not always be as accurate as practitioners believe. In 2006, the Radiological Physics Center (RPC) reported that of…”
Get full text
Conference Proceeding Journal Article -
8
TU‐CD‐BRD‐01: Making Incident Learning Practical and Useful: Challenges and Previous Experiences
Published in Medical physics (Lancaster) (01-06-2015)“…It has long been standard practice in radiation oncology to report internally when a patient's treatment has not gone as planned and to report events to…”
Get full text
Journal Article -
9
EP-2202: Accuracy of and quality assurance for VMAT-based, single isocenter SRS for multiple targets
Published in Radiotherapy and oncology (01-04-2018)Get full text
Journal Article -
10
TU‐D‐T‐6E‐02: Panel Discussion — Why, What, and How Much QA Is Necessary for IMRT?
Published in Medical physics (Lancaster) (01-06-2005)“…Abstract only…”
Get full text
Journal Article -
11
Genetic and geometric optimization of three-dimensional radiation therapy treatment planning
Published in Medical physics (Lancaster) (01-03-1996)“…The thesis of this report is that potentially useful treatment beams can be chosen based on geometric heuristics and that a genetic algorithm (GA) can be…”
Get more information
Journal Article -
12
A manual algorithm for computing dwell times for two-catheter endobronchial treatments using HDR brachytherapy
Published in Medical physics (Lancaster) (01-05-2000)“…A method has been developed to permit the calculation of dwell times for endobronchial high dose rate (HDR) brachytherapy treatment using two catheters,…”
Get full text
Journal Article -
13
WE‐D‐BRA‐01: FEATURED PRESENTATION and BEST IN PHYSICS (THERAPY): Predicting Potentially Problematic VMAT Treatment Plans Before Patient Specific QA Measurements
Published in Medical physics (Lancaster) (01-06-2015)“…Purpose: Several promising IMRT QA tools have been developed in recent years to combat problems found in the lack of sensitivity in planar dose measurements…”
Get full text
Journal Article -
14
WE‐B‐Exhibit Hall‐01: Ask the RO‐ILS Experts
Published in Medical physics (Lancaster) (01-06-2015)“…Have a question about RO‐ILS: Radiation Oncology Incident Learning System™, or interested in learning more? Sponsored by the American Society for Radiation…”
Get full text
Journal Article -
15
SU‐E‐T‐679: Retrospective Analysis of the Sensitivity of Planar Dose Measurements To Gamma Analysis Criteria
Published in Medical physics (Lancaster) (01-06-2015)“…Purpose: IMRT QA using planar dose measurements is still a widely used method for checking the accuracy of treatment plans. A pass/fail judgment is made using…”
Get full text
Journal Article -
16
Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning
Published in Medical physics (Lancaster) (01-12-2007)“…The Monte Carlo (MC) method has been shown through many research studies to calculate accurate dose distributions for clinical radiotherapy, particularly in…”
Get full text
Journal Article -
17
TH‐E‐19A‐01: Quality and Safety in Radiation Therapy
Published in Medical physics (Lancaster) (01-06-2014)“…Clinical radiotherapy data clearly demonstrate the link between the quality and safety of radiation treatments and the outcome for patients. The medical…”
Get full text
Journal Article -
18
TU-D-201-04: Veracity of Data Elements in Radiation Oncology Incident Learning Systems
Published in Medical physics (Lancaster) (01-06-2016)“…Purpose: Incident learning systems encompass volumes, varieties, values, and velocities of underlying data elements consistent with the V’s of big data…”
Get full text
Journal Article -
19
Limitations of the straight-line assumption for endobronchial HDR brachytherapy treatments
Published in Medical physics (Lancaster) (01-01-2000)“…It is useful to expedite high dose rate brachytherapy endobronchial treatments by using standardized dwell weights and worksheets, avoiding computerized…”
Get full text
Journal Article -
20
Permanent 125iodine implants for recurrent malignant gliomas
Published in International journal of radiation oncology, biology, physics (15-03-1999)“…To determine the efficacy and toxicity of permanent 125iodine implants for recurrent malignant gliomas. Between January 1989 and January:, 59 patients with…”
Get more information
Journal Article