Search Results - "Escudero, María Lorenza"
-
1
Implantation of heat treatment Ti6al4v alloys in femoral bone of Wistar rats
Published in Journal of materials science. Materials in medicine (03-10-2022)“…Two heat treatments were carried out at below (Ti6Al4V 800 ) and above (Ti6Al4V 1050 ) the beta-phase transformation temperature ( T TRANSUS = 980 °C), to…”
Get full text
Journal Article -
2
Wettability, Corrosion Resistance, and Osteoblast Response to Reduced Graphene Oxide on CoCr Functionalized with Hyaluronic Acid
Published in Materials (06-04-2022)“…The durability of metal-metal prostheses depends on achieving a higher degree of lubrication. The beneficial effect of hyaluronic acid (HA) on the friction and…”
Get full text
Journal Article -
3
Biological Responses in the Blood and Organs of Rats to Intraperitoneal Inoculation of Graphene and Graphene Oxide
Published in Materials (15-04-2022)“…The discrepancy among the in vivo results found in the literature regarding graphene's side effects led us to conduct an in vivo study with graphene. In vivo…”
Get full text
Journal Article -
4
Synthesis and Electrochemical Characterisation of Magnetite Coatings on Ti6Al4V-ELI
Published in Metals (Basel ) (01-12-2020)“…Titanium alloys have been widely employed in implant materials owing to their biocompatibility. The primary limitation of these materials is their poor…”
Get full text
Journal Article -
5
Barrier Graphene Oxide on a CoCr Alloy via Silane/GO Covalent Bonding and Its Electrochemical Behavior in a Simulated Synovial Fluid Electrolyte
Published in Metals (Basel ) (01-08-2023)“…In this work, impermeable and ultrathin surface nanomodifications for joint applications based on graphene oxide (GO) are assembled on CoCr surfaces via…”
Get full text
Journal Article -
6
Effect of Wear-Corrosion of Reduced Graphene Oxide Functionalized with Hyaluronic Acid on Inflammatory and Proteomic Response of J774A.1 Macrophages
Published in Metals (Basel ) (01-03-2023)“…The presence of a worn surface in the implanted material, as in the case of a replacement of a damaged osteoarticular joint, is the normal condition after…”
Get full text
Journal Article -
7
Corrosion Behaviour and J774A.1 Macrophage Response to Hyaluronic Acid Functionalization of Electrochemically Reduced Graphene Oxide on Biomedical Grade CoCr
Published in Metals (Basel ) (01-07-2021)“…Improvements in the lubrication of metal–metal joint prostheses are of great clinical interest in order to minimize the particles released during…”
Get full text
Journal Article -
8
Macrophage Biocompatibility of CoCr Wear Particles Produced under Polarization in Hyaluronic Acid Aqueous Solution
Published in Materials (08-05-2018)“…Macrophages are the main cells involved in inflammatory processes and in the primary response to debris derived from wear of implanted CoCr alloys. The…”
Get full text
Journal Article -
9
Osseointegration of TI6Al4V dental implants modified by thermal oxidation in osteoporotic rabbits
Published in International journal of implant dentistry (21-07-2016)“…Background In this work, the effect of the heat treatment on Ti6Al4V implants and topical administration of growth hormone to address a better osseointegration…”
Get full text
Journal Article -
10
Osteoblast Cell Response on the Ti6Al4V Alloy Heat-Treated
Published in Materials (23-04-2017)“…In an effort to examine the effect of the microstructural changes of the Ti6Al4V alloy, two heat treatments were carried out below (Ti6Al4V ) and above…”
Get full text
Journal Article -
11
Effect of the Heat-Treated Ti6Al4V Alloy on the Fibroblastic Cell Response
Published in Materials (30-12-2017)“…Two heat treatments were carried out below (Ti6Al4V ) and above (Ti6Al4V ) Ti6Al4V beta-phase transformation temperature (980 °C), with the purpose of studying…”
Get full text
Journal Article -
12
Response of MC3T3-E1 osteoblasts, L929 fibroblasts, and J774 macrophages to fluoride surface-modified AZ31 magnesium alloy
Published in Journal of biomedical materials research. Part A (01-10-2013)“…The present work evaluates the biocompatibility of a fluoride surface‐modified AZ31 magnesium alloy (AZ31HF) with different cell lines that coexist in the…”
Get full text
Journal Article -
13
Effect of Heat Treatment on the Electrochemical and Mechanical Behavior of the Ti6Al4V Alloy
Published in Metallurgical and materials transactions. A, Physical metallurgy and materials science (01-08-2021)“…The effects of heat treatment on the hardness and electrochemical behavior of the Ti6Al4V alloy were studied. Two heat treatments were performed: one below…”
Get full text
Journal Article -
14
Corrosion behavior of surface modifications on titanium dental implant. In situ bacteria monitoring by electrochemical techniques
Published in Journal of biomedical materials research. Part B, Applied biomaterials (01-04-2018)“…The effects of surface modifications and bacteria on the corrosion behavior of titanium have been studied. Five surface modifications were analyzed: two acid…”
Get full text
Journal Article -
15
Caracterización y comportamiento frente a la corrosión de recubrimientos de ácido fítico, obtenidos por conversión química, sobre substratos de magnesio en solución fisiológica
Published in Revista de metalurgia (Madrid) (30-06-2014)“…Con objeto de mejorar la resistencia a la corrosión de implantes biodegradables de magnesio y de la aleación AZ31, se ha depositado un recubrimiento de ácido…”
Get full text
Journal Article -
16
Comparative study of the wear resistance of Al2O3-coated MA956 superalloy
Published in Revista de metalurgia (Madrid) (30-10-2000)Get full text
Journal Article -
17
In situ electrochemical study of the interaction of cells with thermally treated titanium
Published in Biointerphases (01-06-2015)“…Micromotion and fretting wear between bone and Ti-based alloys in stem and dental implants breaks the passive film and exposes the metal to the action of the…”
Get full text
Journal Article -
18
Determination of metallic traces in kidneys, livers, lungs and spleens of rats with metallic implants after a long implantation time
Published in Journal of materials science. Materials in medicine (2008)“…Metallic transfer from implants does not stop at surrounding tissues, and metallic elements may be transferred by proteins to become lodged in organs far from…”
Get full text
Journal Article -
19
Preparación de recubrimientos de hidroxiapatita a partir de precursores de tipo sol-gel
Published in Revista CENIC. Ciencias químicas (01-05-2006)“…Desde los años 90, se realizan innumerables investigaciones para obtener un sistema que combine las ventajas mecánicas de los metales y la afinidad biológica…”
Get full text
Journal Article -
20
Preparación de recubrimientos de hidroxiapatita a partir de precursores de tipo sol-gel
Published in Revista CENIC. Ciencias químicas (01-05-2006)“…Desde los años 90, se realizan innumerables investigaciones para obtener un sistema que combine las ventajas mecánicas de los metales y la afinidad biológica…”
Get full text
Journal Article