Search Results - "Ebrahimi, Behrouz"
-
1
Characterization of high-pressure cavitating flow through a thick orifice plate in a pipe of constant cross section
Published in International journal of thermal sciences (01-04-2017)“…To validate the applicability of basic cavitating flow theory for high-pressure flow systems, this paper presents a systematic study of high-pressure flow…”
Get full text
Journal Article -
2
An open-source deep learning network AVA-Net for arterial-venous area segmentation in optical coherence tomography angiography
Published in Communications medicine (17-04-2023)“…Background Differential artery-vein (AV) analysis in optical coherence tomography angiography (OCTA) holds promise for the early detection of eye diseases…”
Get full text
Journal Article -
3
Deep learning-based optical coherence tomography angiography image construction using spatial vascular connectivity network
Published in Communications engineering (09-02-2024)“…Optical coherence tomography angiography (OCTA) provides unrivaled capability for depth-resolved visualization of retinal vasculature at the microcapillary…”
Get full text
Journal Article -
4
Deep learning for artery–vein classification in optical coherence tomography angiography
Published in Experimental Biology and Medicine (01-05-2023)“…Major retinopathies can differentially impact the arteries and veins. Traditional fundus photography provides limited resolution for visualizing retinal…”
Get full text
Book Review Journal Article -
5
Differential Capillary and Large Vessel Analysis Improves OCTA Classification of Diabetic Retinopathy
Published in Investigative ophthalmology & visual science (01-08-2024)“…This study aimed to investigate the impact of distinctive capillary-large vessel (CLV) analysis in optical coherence tomography angiography (OCTA) on the…”
Get full text
Journal Article -
6
Second-Order Sliding Mode Strategy for Air-Fuel Ratio Control of Lean-Burn SI Engines
Published in IEEE transactions on control systems technology (01-07-2014)“…Higher fuel economy and lower exhaust emissions for spark-ignition engines depend significantly on precise air-fuel ratio (AFR) control. However, the presence…”
Get full text
Journal Article -
7
Assessing spectral effectiveness in color fundus photography for deep learning classification of retinopathy of prematurity
Published in Journal of biomedical optics (01-07-2024)“…Retinopathy of prematurity (ROP) poses a significant global threat to childhood vision, necessitating effective screening strategies. This study addresses the…”
Get full text
Journal Article -
8
Optimizing the OCTA layer fusion option for deep learning classification of diabetic retinopathy
Published in Biomedical optics express (01-09-2023)“…The purpose of this study is to evaluate layer fusion options for deep learning classification of optical coherence tomography (OCT) angiography (OCTA) images…”
Get full text
Journal Article -
9
Colour fusion effect on deep learning classification of uveal melanoma
Published in Eye (London) (01-10-2024)“…Background Reliable differentiation of uveal melanoma and choroidal nevi is crucial to guide appropriate treatment, preventing unnecessary procedures for…”
Get full text
Journal Article -
10
Quality Evaluation of Groundwater Resources using Geostatistical Methods (Case Study: Central Lorestan Plain, Iran)
Published in Water resources management (01-09-2018)“…In this research, based on the qualitative data of 40 wells, variations of water quality parameters of the Central Plain Aquifer were evaluated using kriging…”
Get full text
Journal Article -
11
OCTA-ReVA: an open-source toolbox for comprehensive retinal vessel feature analysis in optical coherence tomography angiography
Published in Biomedical optics express (01-10-2024)“…Optical coherence tomography angiography (OCTA) has significantly advanced the study and diagnosis of eye diseases. However, current clinical OCTA systems and…”
Get full text
Journal Article -
12
Differential artery-vein analysis improves the OCTA classification of diabetic retinopathy
Published in Biomedical optics express (01-06-2024)“…This study investigates the impact of differential artery-vein (AV) analysis in optical coherence tomography angiography (OCTA) on machine learning…”
Get full text
Journal Article -
13
AQM controller design for TCP networks based on a new control strategy
Published in Telecommunication systems (01-12-2014)“…When the network suffers from congestion, the core or edge routers signal the incidence of congestion through the active queue management (AQM) to the sources…”
Get full text
Journal Article -
14
A dynamic feedback control strategy for control loops with time-varying delay
Published in International journal of control (04-05-2014)“…Dynamic systems of nth order with time-varying delay in the control loop are examined in this paper. The infinite-dimensional pure delay problem is…”
Get full text
Journal Article -
15
A second order sliding mode strategy for fault detection and fault-tolerant-control of a MEMS optical switch
Published in Mechatronics (Oxford) (01-09-2012)“…Optical switches are widely used in telecommunication industry due to their many desirable characteristics. In this paper, robust fault detection and…”
Get full text
Journal Article -
16
Normalized Blood Flow Index in Optical Coherence Tomography Angiography Provides a Sensitive Biomarker of Early Diabetic Retinopathy
Published in Translational vision science & technology (05-04-2023)“…To evaluate the sensitivity of normalized blood flow index (NBFI) for detecting early diabetic retinopathy (DR). Optical coherence tomography angiography…”
Get full text
Journal Article -
17
A compensated PID active queue management controller using an improved queue dynamic model
Published in International journal of communication systems (01-12-2014)“…SUMMARYBeside the major objective of providing congestion control, achieving predictable queuing delay, maximizing link utilization, and robustness are the…”
Get full text
Journal Article -
18
Multispectral Fundus Photography of Choroidal Nevi With Trans-Palpebral Illumination
Published in Translational vision science & technology (01-03-2024)“…The purpose of this study was to investigate the spectral characteristics of choroidal nevi and assess the feasibility of quantifying the basal diameter of…”
Get full text
Journal Article -
19
Optimal sliding-mode guidance with terminal velocity constraint for fixed-interval propulsive maneuvers
Published in Acta astronautica (01-05-2008)“…An optimal strategy based on minimum control effort with terminal position and velocity constraints is developed for an exoatmospheric interceptor in order to…”
Get full text
Journal Article -
20
Robust control of a nonlinear non-minimum phase supersonic flight vehicle based on stable system center
Published in Aerospace science and technology (01-03-2013)“…Design and synthesis of a nonlinear time-varying and non-minimum phase supersonic flight vehicle longitudinal dynamics control for g-commands output tracking…”
Get full text
Journal Article