Search Results - "ESTES, N. A. M. III"
-
1
Efficacy of Implantable Cardioverter–Defibrillators for the Prevention of Sudden Death in Patients with Hypertrophic Cardiomyopathy
Published in The New England journal of medicine (10-02-2000)“…Hypertrophic cardiomyopathy is a genetically determined myocardial disease with a diverse natural history. 1 – 7 Since a subgroup of patients with hypertrophic…”
Get full text
Journal Article -
2
Diagnosing syncope : Part 1 : Value of history, physical examination, and electrocardiography
Published in Annals of internal medicine (15-06-1997)Get full text
Journal Article -
3
Diagnosing syncope. Part 2 : Unexplained syncope
Published in Annals of internal medicine (01-07-1997)Get full text
Journal Article -
4
Quality of Life and Clinical Outcomes in Elderly Patients Treated with Ventricular Pacing as Compared with Dual-Chamber Pacing
Published in The New England journal of medicine (16-04-1998)“…Pacemaker technology and clinical practice in the United States permit the use of either single-chamber ventricular pacemakers or dual-chamber pacemakers for…”
Get full text
Journal Article -
5
An Experimental Model of Sudden Death Due to Low-Energy Chest-Wall Impact (Commotio Cordis)
Published in The New England journal of medicine (18-06-1998)“…We also studied whether the use of safety baseballs, which are softer than standard ones, would reduce the risk of arrhythmia. A total of 48 additional animals…”
Get full text
Journal Article -
6
Interference with Cardiac Pacemakers by Cellular Telephones
Published in The New England journal of medicine (22-05-1997)“…Reports of interference between European cellular telephones and cardiac pacemakers in 1994 1 – 3 prompted the U.S. government and researchers to examine the…”
Get full text
Journal Article -
7
Mechanisms of death in the CABG Patch Trial : A randomized Trial of implantable cardiac Defibrillator prophylaxis in patients at high risk of death after coronary artery bypass graft surgery
Published in Circulation (New York, N.Y.) (23-03-1999)“…The CABG Patch trial compared prophylactic implantable cardiac-defibrillator (ICD) implantation with no antiarrhythmic therapy in coronary bypass surgery…”
Get full text
Journal Article -
8
Selective activation of the K+ATP channel is a mechanism by which sudden death is produced by low-energy chest-wall impact (commotio cordis)
Published in Circulation (New York, N.Y.) (27-07-1999)“…Background —Sudden death due to relatively innocent chest-wall impact has been described in young individuals (commotio cordis). In our previously reported…”
Get full text
Journal Article -
9
Comparison of frequency of complications of implantable cardioverter-defibrillators in children versus adults
Published in The American journal of cardiology (15-01-1999)“…Compared with adults patients (n = 309) receiving implantable cardioverter-defibrillators at the same institution, pediatric patients (n = 11) exhibited a…”
Get full text
Journal Article -
10
Electrical Alternans During Rest and Exercise as Predictors of Vulnerability to Ventricular Arrhythmias
Published in The American journal of cardiology (15-11-1997)“…This investigation was performed to evaluate the feasibility of detecting repolarization alternans with the heart rate elevated with a bicycle exercise…”
Get full text
Journal Article -
11
Analysis of intracardiac electrograms showing monomorphic ventricular tachycardia in patients with implantable cardioverter-defibrillators
Published in The American journal of cardiology (01-03-2000)“…Ventricular tachycardia (VT) initiation and its relation to various clinical factors was studied by reviewing intracardiac electrograms from patients with…”
Get full text
Journal Article -
12
Complications of dual chamber Pacemaker implantation in the Elderly
Published in Journal of interventional cardiac electrophysiology (01-06-1998)“…Pacemakers are frequently implanted, yet accurate prospective data on implant complications are limited. Elderly patients may be at increased risk of implant…”
Get full text
Journal Article -
13
Long-term outcome of patients with syncope associated with coronary artery disease and a nondiagnostic electrophysiologic evaluation
Published in The American journal of cardiology (01-05-1999)“…Syncope in the patient with structural heart disease and a nondiagnostic noninvasive workup is a generally accepted indication for an invasive…”
Get full text
Journal Article -
14
Commotio cordis: cardiovascular manifestations of a rare survivor
Published in Chest (01-07-1998)“…Death due to low-energy chest wall trauma, commotio cordis, may occur in young athletes. Death is sudden and usually refractory to even immediate resuscitation…”
Get more information
Journal Article -
15
Perioperative and long-term results with mapping-guided subendocardial resection and left ventricular endoaneurysmorrhaphy
Published in Circulation (New York, N.Y.) (01-09-1996)“…Surgical ablation of the arrhythmogenic focus in patients with life-threatening ventricular tachyarrhythmias can be curative. However, the surgical techniques…”
Get full text
Journal Article -
16
Baseline characteristics of patients in the Coronary Artery Bypass Graft (CABG) Patch Trial
Published in The American heart journal (01-11-1997)“…Background Patients with left ventricular dysfuntion who undergo coronary artery bypass graft (CABG) surgery frequently have late sudden cardiac death. The…”
Get full text
Journal Article -
17
A teenager with pacemaker twiddler syndrome
Published in The Journal of pediatrics (01-09-1997)Get full text
Journal Article -
18
A consensus report on antiarrhythmic drug use
Published in Clinical cardiology (Mahwah, N.J.) (01-03-1994)“…During the past few years, a number of new antiarrhythmic agents have become available for use in the United States, encainide has been withdrawn from use, and…”
Get more information
Journal Article -
19
Evaluation of coronary revascularization to prevent tachycardia recurrences in survivors of ventricular fibrillation
Published in The American journal of cardiology (15-03-1999)“…Long-term follow-up of 29 consecutive survivors of ventricular fibrillation who underwent revascularization demonstrated that recurrent arrhythmics events were…”
Get full text
Journal Article -
20
Pacemaker lead infection: Detection by multiplane transesophageal echocardiography
Published in The American heart journal (01-03-1996)“…Infection of a permanent pacemaker system occurs with an estimated incidence of 0.2% to 3%. Staphylococcal species account for most pacemaker infections, which…”
Get full text
Journal Article