Effective Doses and Excess Lifetime Cancer Risks from Absorbed Dose Rates Measured in Facilities of Two Tertiary Institutions in Nigeria

This study was aimed at examining the radiation absorbed dose rate, annual effective doses and excess lifetime cancer risks of halls of residence, Radiotherapy Unit and Radiology Department of UI, UCH and UNIMEDTH respectively. Results of measurements show that the mean absorbed dose rate for male a...

Full description

Saved in:
Bibliographic Details
Published in:Journal of Applied Sciences and Environmental Management Vol. 26; no. 10
Main Authors: C. J. Olowookere, N. N. Jibiri, E. O. Oyekunle, J. Fatukasi, E. S. Osho, A. A. Raheem, D. B. Adejumo, T. A. Awolola
Format: Journal Article
Language:English
Published: Joint Coordination Centre of the World Bank assisted National Agricultural Research Programme (NARP) 31-10-2022
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:This study was aimed at examining the radiation absorbed dose rate, annual effective doses and excess lifetime cancer risks of halls of residence, Radiotherapy Unit and Radiology Department of UI, UCH and UNIMEDTH respectively. Results of measurements show that the mean absorbed dose rate for male and female hall are 0.33 ± 0.05476 and 0.17 ± 0.05074 µSv h-1 respectively. The mean overall absorbed dose rates calculated for facilities studied are 0.269 ± 0.0992 µSv h-1, 0.121 ± 0.036 µSv h-1 and 0.123 ± 0.00931 µSv h-1 in UI, UCH and UNIMEDTH respectively. The mean annual effective doses recorded in both male and female halls in University of Ibadan ranges between 0.71 mSv y-1 and 2.67 mSv y-1. The mean annual effective doses obtained from the facility of University of Medical Sciences Teaching Hospital, Ondo (UNIMEDTH) ranges between 0.17 and 0.44 mSv y-1. In addition, the mean annual effective doses calculated from the measured absorbed dose rate in Radiotherapy Department of University College Hospital, Ibadan ranges between 0.20 and 1.22 mSv y-1. As regards ELCRs, the mean values  determined in various facilities examined are 6.07 x 10-3 (Male Halls, UI), 3.27 x 10-3 (Female Halls, UI), 0.57 x 10-3 (UNIMEDTH- NE), 0.99 x 10-3 (UNIMEDTH- EX), 0.65 x x 10-3 (Teletherapy, UCH) and 0.57 x 10-3 (Brachytherapy, UCH).The mean ELCRs of both halls examined are higher than the world average of 1.45 x 10-3 and the standard value of 0.29 x 10-3 by at least a factor of 1.97 units.
ISSN:2659-1502
2659-1499
DOI:10.4314/jasem.v26i10.14