Search Results - "Dreossi, D"
-
1
Local anisotropy analysis of injection moulded fibre reinforced polymer composites
Published in Composites science and technology (01-09-2008)“…The fibre orientation distribution in a material sample extracted from an injection moulded plate, displaying the commonly encountered layered shell–core–shell…”
Get full text
Journal Article -
2
X-ray Phase-Contrast Radiography and Tomography with a Multiaperture Analyzer
Published in Physical review letters (16-06-2017)“…We present a multiaperture analyzer setup for performing x-ray phase contrast imaging in planar and three-dimensional modalities. The method is based on…”
Get full text
Journal Article -
3
Towards breast tomography with synchrotron radiation at Elettra: first images
Published in Physics in medicine & biology (21-02-2016)“…The aim of the SYRMA-CT collaboration is to set-up the first clinical trial of phase-contrast breast CT with synchrotron radiation (SR). In order to combine…”
Get more information
Journal Article -
4
Optimization of propagation-based x-ray phase-contrast tomography for breast cancer imaging
Published in Physics in medicine & biology (21-03-2017)“…The aim of this study was to optimise the experimental protocol and data analysis for in-vivo breast cancer x-ray imaging. Results are presented of the…”
Get more information
Journal Article -
5
The ICTP-Elettra X-ray laboratory for cultural heritage and archaeology
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-05-2013)“…A set of portable/transportable X-ray analytical instruments based on radiography, microtomography, fluorescence and diffraction have been built and are being…”
Get full text
Journal Article -
6
Theory and preliminary experimental verification of quantitative edge illumination x-ray phase contrast tomography
Published in Optics express (07-04-2014)“…X-ray phase contrast imaging (XPCi) methods are sensitive to phase in addition to attenuation effects and, therefore, can achieve improved image contrast for…”
Get full text
Journal Article -
7
Free propagation phase-contrast breast CT provides higher image quality than cone-beam breast-CT at low radiation doses: a feasibility study on human mastectomies
Published in Scientific reports (24-09-2019)“…In this study we demonstrate the first direct comparison between synchrotron x-ray propagation-based CT (PB-CT) and cone-beam breast-CT (CB-CT) on human…”
Get full text
Journal Article -
8
Measurement of the linear attenuation coefficients of breast tissues by synchrotron radiation computed tomography
Published in Physics in medicine & biology (07-09-2010)“…The measurement of the linear attenuation coefficients of breast tissues is of fundamental importance in the field of breast x-ray diagnostic imaging…”
Get more information
Journal Article -
9
DID NEANDERTHALS PLAY MUSIC? X-RAY COMPUTED MICRO-TOMOGRAPHY OF THE DIVJE BABE 'FLUTE'
Published in Archaeometry (01-06-2012)“…Archaeological evidence for wind musical instruments made by modern humans has been well established from the Upper Palaeolithic in Europe. Musical instruments…”
Get full text
Journal Article -
10
Clinical application of low-dose phase contrast breast CT: methods for the optimization of the reconstruction workflow
Published in Biomedical optics express (01-08-2015)“…Results are presented of a feasibility study of three-dimensional X-ray tomographic mammography utilising in-line phase contrast. Experiments were performed at…”
Get full text
Journal Article -
11
Airborne LiDAR application to karstic areas: the example of Trieste province (north-eastern Italy) from prehistoric sites to Roman forts
Published in Journal of archaeological science (01-04-2013)“…The Trieste Karst, at the northernmost shore of the Adriatic Sea, is rich in prehistoric caves and protohistoric hill forts. Most of these archaeological sites…”
Get full text
Journal Article -
12
The effects of the imaging system on the validity limits of the ray-optical approach to phase contrast imaging
Published in Medical physics (Lancaster) (01-12-2005)“…A theoretical analysis of the x-ray phase contrast imaging and its validation via synchrotron radiation imaging is here presented. Two different mathematical…”
Get full text
Journal Article -
13
Three-dimensional Quantitative Analysis of Bread Crumb by X-ray Microtomography
Published in Journal of food science (01-05-2005)“…Phase‐sensitive X‐ray microtomography was used as a nondestructive imaging technique for the computerized reconstruction of three‐dimensional (3D) images of…”
Get full text
Journal Article -
14
3D histomorphometric quantification of trabecular bones by computed microtomography using synchrotron radiation
Published in Micron (Oxford, England : 1993) (01-12-2010)“…Conventional bone histomorphometry is an important method for quantitative evaluation of bone microstructure. X-ray computed microtomography is a non-invasive…”
Get full text
Journal Article -
15
Experimental Characterization of a Parallel Polycapillary Collimator for X-Ray Scatter Imaging
Published in IEEE transactions on nuclear science (01-08-2011)“…The full exploitation of polycapillary lenses in X-ray imaging systems-e.g., based on X-ray fluorescence, X-ray diffraction, X-ray scattering-is strictly…”
Get full text
Journal Article -
16
The mammography project at the SYRMEP beamline
Published in European journal of radiology (01-12-2008)“…Abstract A clinical program for X-ray phase contrast (PhC) mammography with synchrotron radiation (SR) has been started in March 2006 at the SYRMEP beamline of…”
Get full text
Journal Article Conference Proceeding -
17
Structural analysis of rat bone explants kept in vitro in simulated microgravity conditions
Published in Journal of the mechanical behavior of biomedical materials (01-04-2009)“…Skeletal abnormalities reported in humans and laboratory animals after spaceflight, include cancellous osteopenia, decreased cortical and cancellous bone…”
Get full text
Journal Article -
18
Medical applications of synchrotron radiation at the SYRMEP beamline of ELETTRA
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-08-2005)“…The main purpose of the SYRMEP (SYnchrotron Radiation for MEdical Physics) research team is the investigation and development of innovative techniques for…”
Get full text
Journal Article -
19
Effect of spatial coherence on application of in-line phase contrast imaging to synchrotron radiation mammography
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-08-2005)“…Effect of spatial coherence on the application of in-line phase contrast imaging (IL-PCI) to synchrotron radiation (SR) mammography is investigated…”
Get full text
Journal Article -
20
Numerical and experimental structural analysis of trabecular architectures
Published in Meccanica (Milan) (01-02-2007)“…This paper presents the application of the Cell Method (CM) to the static analysis of 3D structures obtained from micro-computed tomography reconstructions of…”
Get full text
Journal Article