Failure analysis in the tube of the refrigeration system of a reheating furnace
•Failure analysis of cooling system tube.•Microstructural changes due to loss of the refractory.•Structural steel tube corrosion due to microstructural changes. This work aimed to analyze a failure that occurred prematurely in an ASTM SS Grade 70 steel tube in the cooling system of a reheating furna...
Saved in:
Published in: | Engineering failure analysis Vol. 120; p. 105052 |
---|---|
Main Authors: | , , , , |
Format: | Journal Article |
Language: | English |
Published: |
Elsevier Ltd
01-02-2021
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | •Failure analysis of cooling system tube.•Microstructural changes due to loss of the refractory.•Structural steel tube corrosion due to microstructural changes.
This work aimed to analyze a failure that occurred prematurely in an ASTM SS Grade 70 steel tube in the cooling system of a reheating furnace. The following techniques were used: visual inspection, optical microscopy (OM), scanning electron microscopy (SEM), chemical analysis by energy dispersive spectroscopy (EDS), Vickers microhardness (HV) and measurements and chemical analysis by optical emission spectrometry (OES). It was concluded that the failure was caused by a drastic corrosion process, due to microstructural changes resulting from the loss of the refractory coating. |
---|---|
ISSN: | 1350-6307 1873-1961 |
DOI: | 10.1016/j.engfailanal.2020.105052 |