Search Results - "Dimitrov, I E"

  • Showing 1 - 9 results of 9
Refine Results
  1. 1
  2. 2

    Functionalized Xenon as a Biosensor by Spence, Megan M., Rubin, Seth M., Dimitrov, Ivan E., Ruiz, E. Janette, Wemmer, David E., Pines, Alexander, Yao, Shao Qin, Tian, Feng, Schultz, Peter G.

    “…The detection of biological molecules and their interactions is a significant component of modern biomedical research. In current biosensor technologies,…”
    Get full text
    Journal Article
  3. 3
  4. 4

    An MR imaging method for simultaneous measurement of gaseous diffusion constant and longitudinal relaxation time by Dimitrov, Ivan E., Charagundla, Sridhar R., Rizi, Rahim, Reddy, Ravinder, Leigh, John S.

    Published in Magnetic resonance imaging (01-02-1999)
    “…A magnetic resonance imaging method for simultaneous and accurate determination of gaseous diffusion constant and longitudinal relaxation time is presented…”
    Get full text
    Journal Article
  5. 5

    Demonstration of a compact compressor for application of metastability-exchange optical pumping of 3He to human lung imaging by Gentile, Thomas R., Jones, Gordon L., Thompson, Alan K., Rizi, Rahim R., Roberts, David A., Dimitrov, Ivan E., Reddy, Ravinder, Lipson, David A., Gefter, Warren, Schnall, Mitchell D., Leigh, John S.

    Published in Magnetic resonance in medicine (01-02-2000)
    “…Hyperpolarized gas magnetic resonance imaging has recently emerged as a method to image lungs, sinuses, and the brain. The best lung images to date have been…”
    Get full text
    Journal Article
  6. 6

    MRI of hyperpolarized 3He gas in human paranasal sinuses by Rizi, R R, Dimitrov, I E, Thompson, A, Jones, G, Gentile, T R, Ishii, M, Reddy, R, Schnall, M D, Leigh, J S

    Published in Magnetic resonance in medicine (01-06-1998)
    “…In this study, MRI of hyperpolarized 3He gas in human paranasal sinuses is presented. Helium images were obtained at 1.5 T, using a surface coil and a 2D, fast…”
    Get more information
    Journal Article
  7. 7

    Intermolecular dipole-dipole relaxation of (129)Xe dissolved in water by Dimitrov, I E, Reddy, R, Leigh, J S

    Published in Journal of magnetic resonance (1997) (01-08-2000)
    “…Intermolecular (129)Xe-(1)H nuclear Overhauser effects and (129)Xe longitudinal relaxation time measurements were used to demonstrate that the dipole-dipole…”
    Get full text
    Journal Article
  8. 8

    Indirect detection of lung perfusion using susceptibility-based hyperpolarized gas imaging by Dimitrov, Ivan E., Insko, Erik, Rizi, Rahim, Leigh, John S.

    Published in Journal of magnetic resonance imaging (01-02-2005)
    “…Purpose To address the problem of inadequate signal‐to‐noise ratio (SNR) encountered in lung perfusion magnetic resonance imaging (MRI) by developing an…”
    Get full text
    Journal Article
  9. 9