Search Results - "Di Micco, Luigi"
-
1
Automatic Setup of a Pulse Duplicator Apparatus through a Dither-free ESC Approach
Published in 2023 31st Mediterranean Conference on Control and Automation (MED) (26-06-2023)“…With the help of in-vitro simulators, it is possible to simulate human physiological conditions to test medical equipment, accelerating innovation cycles and…”
Get full text
Conference Proceeding -
2
Distensibility of Deformable Aortic Replicas Assessed by an Integrated In-Vitro and In-Silico Approach
Published in Bioengineering (Basel) (26-02-2022)“…The correct estimation of the distensibility of deformable aorta replicas is a challenging issue, in particular when its local characterization is necessary…”
Get full text
Journal Article -
3
Numerical Models Can Assist Choice of an Aortic Phantom for In Vitro Testing
Published in Bioengineering (Basel) (21-07-2021)“…(1) Background: The realization of appropriate aortic replicas for in vitro experiments requires a suitable choice of both the material and geometry. The…”
Get full text
Journal Article -
4
Automation of the peripheral resistance valve in a hydro-mechanical cardiovascular pulse duplicator system
Published in Control engineering practice (01-11-2021)“…This paper considers the modernization of an existing non-commercial Pulse Duplicator in use at the Healing Research Laboratory at the University of Padova,…”
Get full text
Journal Article -
5
Beating heart implantation of transventricular artificial cordae: How can access site selection and leaflet insertion improve mitral regurgitation correction?
Published in Medical engineering & physics (01-03-2022)“…•NeoChord and Harpoon are two techniques for treating mitral valve prolapse;.•Numerical analysis of access site selection and leaflet insertion is carried…”
Get full text
Journal Article -
6
The neochord mitral valve repair procedure: Numerical simulation of different neochords tensioning protocols
Published in Medical engineering & physics (01-12-2019)“…•The NeoChord procedure is a new technique for treating mitral valve prolapse.•Numerical model of MV for verifying intra-operative effects of NeoChord…”
Get full text
Journal Article -
7
Mimicking the Complex Human Circulatory System via a Custom Hydro-mechanical Pulse Duplicator
Published in 2022 IEEE Workshop on Complexity in Engineering (COMPENG) (18-07-2022)“…The complex human systemic circulation can be mimicked by exploiting in vitro simulators, giving the chance to replicate both physiological and pathological…”
Get full text