Search Results - "Deng, Sophie X."
-
1
The application of human amniotic membrane in the surgical management of limbal stem cell deficiency
Published in The ocular surface (01-04-2019)“…The application of human amniotic membrane (AM) has a wide spectrum of indications in the treatment of ocular surface disorders. Transplantation of AM has been…”
Get full text
Journal Article -
2
Global Consensus on Definition, Classification, Diagnosis, and Staging of Limbal Stem Cell Deficiency
Published in Cornea (01-03-2019)“…PURPOSE:Despite extensive knowledge gained over the last 3 decades regarding limbal stem cell deficiency (LSCD), the disease is not clearly defined, and there…”
Get full text
Journal Article -
3
Corneal Epithelial Thickness Measured Using Anterior Segment Optical Coherence Tomography as a Diagnostic Parameter for Limbal Stem Cell Deficiency
Published in American journal of ophthalmology (01-08-2020)“…Using anterior segment optical coherence tomography (AS-OCT), we investigated the epithelial thickness (ET) of the central cornea and limbal regions in…”
Get full text
Journal Article -
4
Mesenchymal Stem Cells Reduce Corneal Fibrosis and Inflammation via Extracellular Vesicle‐Mediated Delivery of miRNA
Published in Stem cells translational medicine (01-11-2019)“…Mesenchymal stem cells from corneal stromal stem cells (CSSC) prevent fibrotic scarring and stimulate regeneration of transparent stromal tissue after corneal…”
Get full text
Journal Article -
5
Global Consensus on the Management of Limbal Stem Cell Deficiency
Published in Cornea (01-10-2020)“…PURPOSE:In recent decades, the medical and surgical treatment of limbal stem cell deficiency (LSCD) has evolved significantly through the incorporation of…”
Get full text
Journal Article Conference Proceeding -
6
Assessment of corneal epithelial thickness in dry eye patients
Published in Optometry and vision science (01-12-2014)“…To investigate the features of corneal epithelial thickness topography with Fourier-domain optical coherence tomography (OCT) in dry eye patients. In this…”
Get full text
Journal Article -
7
Regulation of Limbal Epithelial Stem Cells: Importance of the Niche
Published in International journal of molecular sciences (05-11-2021)“…Limbal epithelial stem/progenitor cells (LSCs) reside in a niche that contains finely tuned balances of various signaling pathways including Wnt, Notch, BMP,…”
Get full text
Journal Article -
8
Classification of Limbal Stem Cell Deficiency Using Clinical and Confocal Grading
Published in Cornea (01-01-2019)“…PURPOSE:To grade the severity of limbal stem cell deficiency (LSCD) based on the extent of clinical presentation and central corneal basal epithelial cell…”
Get full text
Journal Article -
9
Wnt activation as a potential therapeutic approach to treat partial limbal stem cell deficiency
Published in Scientific reports (21-09-2023)“…Limbal epithelial stem/progenitor cells (LSCs) are adult stem cells located at the limbus, tightly regulated by their niche involving numerous signaling…”
Get full text
Journal Article -
10
Stability and Function of Extracellular Vesicles Derived from Immortalized Human Corneal Stromal Stem Cells: A Proof of Concept Study
Published in The AAPS journal (05-12-2022)“…With significant advancement and development of extracellular vesicle (EV)-based therapies, there is a growing need to understand how their storage affects…”
Get full text
Journal Article -
11
Ultrastructure of the Posterior Corneal Stroma
Published in Ophthalmology (Rochester, Minn.) (01-04-2015)“…Purpose To reinvestigate the ultrastructure of the posterior stroma of the human cornea and to correlate the findings with the stromal behavior after…”
Get full text
Journal Article -
12
Wnt6 plays a complex role in maintaining human limbal stem/progenitor cells
Published in Scientific reports (22-10-2021)“…The corneal epithelium is consistently regenerated by limbal stem/progenitor cells (LSCs), a very small population of adult stem cells residing in the limbus…”
Get full text
Journal Article -
13
Identification of novel molecular markers through transcriptomic analysis in human fetal and adult corneal endothelial cells
Published in Human molecular genetics (01-04-2013)“…The corneal endothelium is composed of a monolayer of corneal endothelial cells (CECs), which is essential for maintaining corneal transparency. To better…”
Get full text
Journal Article -
14
Generation of Functional Immortalized Human Corneal Stromal Stem Cells
Published in International journal of molecular sciences (02-11-2022)“…In addition to their therapeutic potential in regenerative medicine, human corneal stromal stem cells (CSSCs) could serve as a powerful tool for drug discovery…”
Get full text
Journal Article -
15
Expansion of Human Limbal Epithelial Stem/Progenitor Cells Using Different Human Sera: A Multivariate Statistical Analysis
Published in International journal of molecular sciences (25-08-2020)“…Transplantation of human cultured limbal epithelial stem/progenitor cells (LESCs) has demonstrated to restore the integrity and functionality of the corneal…”
Get full text
Journal Article -
16
THz and mm-Wave Sensing of Corneal Tissue Water Content: In Vivo Sensing and Imaging Results
Published in IEEE transactions on terahertz science and technology (01-03-2015)“…A pulsed terahertz (THz) imaging system and millimeter-wave reflectometer were used to acquire images and point measurements, respectively, of five rabbit…”
Get full text
Journal Article -
17
Genome-wide analysis suggests a differential microRNA signature associated with normal and diabetic human corneal limbus
Published in Scientific reports (14-06-2017)“…Small non-coding RNAs, in particular microRNAs (miRNAs), regulate fine-tuning of gene expression and can impact a wide range of biological processes. However,…”
Get full text
Journal Article -
18
Human adipose-derived stem cells support the growth of limbal stem/progenitor cells
Published in PloS one (11-10-2017)“…The most efficient method to expand limbal stem cells (LSCs) in vitro for clinical transplantation is to culture single LSCs directly on growth-arrested mouse…”
Get full text
Journal Article -
19
Corneal epithelial thickness map in long-term soft contact lenses wearers
Published in Optometry and vision science (01-12-2014)“…To map the corneal epithelial thickness in vivo with Fourier-domain optical coherence tomography in long-term soft contact lens (SCL) wearers. This is a…”
Get full text
Journal Article -
20
Submillimeter-wave cornea phantom sensing over an extended depth of field with an axicon-generated Bessel beam
Published in IEEE transactions on terahertz science and technology (01-03-2023)“…The feasibility of a 220 - 330 GHz zero order axicon generated Bessel beam for corneal water content was explored. Simulation and experimental data from the…”
Get full text
Journal Article