Current clinical practice in adapted automated peritoneal dialysis (aAPD)-A prospective, non-interventional study
Published in PloS one (09-12-2021)“…Adapted automated peritoneal dialysis (aAPD), comprising a sequence of dwells with different durations and fill volumes, has been shown to enhance both…”
Get full text
Journal Article -
2
Association of Prescription With Body Composition and Patient Outcomes in Incident Peritoneal Dialysis Patients
Published in Frontiers in medicine (24-12-2021)“…The nutritional status of patients on peritoneal dialysis (PD) is influenced by patient- and disease-related factors and lifestyle. This analysis evaluated the…”
Get full text
Journal Article -
3
The impact of volume overload on technique failure in incident peritoneal dialysis patients
Published in Clinical kidney journal (01-02-2021)“…Technique failure in peritoneal dialysis (PD) can be due to patient- and procedure-related factors. With this analysis, we investigated the association of…”
Get full text
Journal Article -
4
Effect of balance Solution on the Peritoneal Membrane in Automated Peritoneal Dialysis
Published in Peritoneal dialysis international (01-09-2016)“…Interference of conventional peritoneal dialysis fluids (cPDFs) with peritoneal membrane cell functions may be attributed to the dialysis fluid's low pH, high…”
Get full text
Journal Article -
5
Evolution Over Time of Volume Status and PD-Related Practice Patterns in an Incident Peritoneal Dialysis Cohort
Published in Clinical journal of the American Society of Nephrology (07-06-2019)“…Volume overload is frequent in prevalent patients on kidney replacement therapies and is associated with outcome. This study was devised to follow-up volume…”
Get full text
Journal Article -
6
BIOCOMPATIBILITY AND TOLERABILITY OF A PURELY BICARBONATE-BUFFERED PERITONEAL DIALYSIS SOLUTION
Published in Peritoneal dialysis international (2009)“…Novel peritoneal dialysis solutions are characterized by a minimal content of glucose degradation products and a neutral pH. Many studies have shown the…”
Get full text
Journal Article -
7
Baseline hydration status in incident peritoneal dialysis patients: the initiative of patient outcomes in dialysis (IPOD-PD study)
Published in Nephrology, dialysis, transplantation (01-05-2015)“…Non-euvolaemia in peritoneal dialysis (PD) patients is associated with elevated mortality risk. There is an urgent need to collect data to help us understand…”
Get full text
Journal Article -
8
-
9
-
10
Current clinical practice in adapted automated peritoneal dialysis
Published in PloS one (09-12-2021)“…Adapted automated peritoneal dialysis (aAPD), comprising a sequence of dwells with different durations and fill volumes, has been shown to enhance both…”
Get full text
Journal Article -
11
Current clinical practice in adapted automated peritoneal dialysis (aAPD)-A prospective, non-interventional study
Published in PloS one (01-01-2021)“…Adapted automated peritoneal dialysis (aAPD), comprising a sequence of dwells with different durations and fill volumes, has been shown to enhance both…”
Get full text
Journal Article -
12
SP507ADAPTED APD (aAPD), WHAT IS THE ACTUAL PRACTICE? DATA OF THE PD-IDEA STUDY (PD-IMPROVED DIALYSIS EFFICIENCY WITH aAPD)
Published in Nephrology, dialysis, transplantation (01-06-2019)Get full text