Search Results - "Dabezies, E"
-
1
Fractures in very low birth weight infants with rickets
Published in Clinical orthopaedics and related research (01-02-1997)“…A syndrome in very low birth weight premature infants weighing less than 1500 g is evidenced by developmental nutritional rickets and fractures at 75 days of…”
Get more information
Journal Article -
2
Magnetic Resonance Imaging of the Interosseous Membrane of the Forearm
Published in Journal of bone and joint surgery. American volume (01-02-2001)“…BackgroundDiagnosis of damage to the interosseous membrane of the forearm after trauma is difficult. Patients with a proximal radial fracture and associated…”
Get full text
Journal Article -
3
Neural anatomy of the human anterior cruciate ligament
Published in Journal of bone and joint surgery. American volume (01-02-1987)“…The histology of the anterior cruciate ligament was studied by a modified technique of the Gairns gold chloride stain for neural elements. Three morphological…”
Get full text
Journal Article -
4
Plate fixation of the humeral shaft for acute fractures, with and without radial nerve injuries
Published in Journal of orthopaedic trauma (1992)“…We report herein the results of operatively treating 44 consecutive acute fractures of the humeral shaft using plates for internal fixation. Ninety-seven…”
Get more information
Journal Article -
5
Tissue expansion prior to revision total knee arthroplasty
Published in The Journal of arthroplasty (01-06-1997)“…The first case of the use of a tissue expander in revision total knee surgery is reported. A 76-year-old woman presented with extremely adherent scar tissue on…”
Get full text
Journal Article -
6
Ganglions of the proximal interphalangeal joint
Published in Orthopedics (Thorofare, N.J.) (01-08-2000)“…Ganglions of the proximal interphalangeal joint are uncommon. Six patients (nine ganglions) were treated surgically. The lesions presented on the ulnar aspect…”
Get full text
Journal Article -
7
Stabilization of sacroiliac joint disruption with threaded compression rods
Published in Clinical orthopaedics and related research (01-09-1989)“…Eleven cases of sacroiliac dislocation and/or fracture (Malgaigne pattern) were successfully reduced and stabilized using two threaded compression rods. The…”
Get more information
Journal Article -
8
Factors affecting postoperative flexion in total knee arthroplasty
Published in Orthopedics (Thorofare, N.J.) (01-06-1990)“…In the review of 67 cases with total condylar (TC) prostheses, 59 with TC posterior stabilizers, 70 with TC prostheses modified with flat posterior tibial…”
Get more information
Journal Article -
9
Femoral osteotomy for secondary arthritis of the hip in young adults
Published in Canadian Journal of Surgery (01-02-1995)“…Osteotomy around the hip is a valuable and important treatment option in hip disease. It may be used on either side of the joint or in a combined fashion. The…”
Get full text
Journal Article -
10
The small pin circular fixator for proximal tibial fractures with soft tissue compromise
Published in Orthopedics (Thorofare, N.J.) (01-03-1991)“…We used a Monticelli-Spinelli small pin circular external fixator in five cases, in combination with closed reduction or limited open reduction internal…”
Get more information
Journal Article -
11
Lateral compartment arthritis of the knee accelerated by medial displacement osteotomy of hip fractures
Published in Orthopedics (Thorofare, N.J.) (01-09-1992)Get more information
Journal Article -
12
Safety and efficacy of chymopapain (Discase) in the treatment of sciatica due to a herniated nucleus pulposus. Results of a randomized, double-blind study
Published in Spine (Philadelphia, Pa. 1976) (01-05-1988)“…A prospective, multiinstitutional, double-blind trial comparing the effect of chymopapain (Discase) vs. placebo (cysteine-edetate-iothalamate: CEI) for lumbar…”
Get more information
Journal Article -
13
Hand infections in patients with diabetes mellitus
Published in Orthopedics (Thorofare, N.J.) (01-11-2001)“…Fifty diabetic patients with hand infections were studied retrospectively. The cause of infection varied, and the infections were divided into two groups:…”
Get full text
Journal Article -
14
Surgery and Arthroscopy of the Knee
Published in Journal of bone and joint surgery. American volume (01-06-1989)Get full text
Journal Article -
15
Symptomatic recurrent patella dislocation in a patient with dyschondrosteosis (Leri Weill syndrome)
Published in Orthopedics (Thorofare, N.J.) (01-05-1995)Get more information
Journal Article -
16
The small pin circular fixator for distal tibial pilon fractures with soft tissue compromise
Published in Orthopedics (Thorofare, N.J.) (01-03-1991)“…A Monticelli-Spinelli small pin circular external fixator was used in combination with closed reduction or a limited open reduction internal fixation in five…”
Get more information
Journal Article -
17
Fixation of metacarpal and phalangeal fractures with miniature plates and screws
Published in The Journal of hand surgery (American ed.) (01-03-1986)“…Fifty-two unstable metacarpal and phalangeal fractures were treated with miniature plates and screws as internal fixation devices with excellent results based…”
Get more information
Journal Article -
18
Enhanced spino-pelvic fixation for segmental spinal instrumentation: a preliminary biomechanical evaluation
Published in Orthopedics (Thorofare, N.J.) (01-06-1994)“…A new method for spino-pelvic fixation of Luque rods was developed and biomechanically evaluated on cadaveric specimens. The technique is surgically simpler…”
Get more information
Journal Article -
19
Interlocking intramedullary fixation of hand fractures
Published in Orthopedics (Thorofare, N.J.) (01-02-1993)“…Reduction and stabilization can be especially difficult in treating comminuted hand fractures with bone loss or nonunion. Two cases are presented to illustrate…”
Get more information
Journal Article -
20
Measurement of effective pedicle diameter in the human spine
Published in Orthopedics (Thorofare, N.J.) (01-07-1989)“…Effective pedicle diameter (EPD), the maximal cancellous diameter of the spinal pedicle, demonstrates the maximal diameter available for transpedicular screw…”
Get more information
Journal Article