Search Results - "DICKMANDER, D. L"

  • Showing 1 - 12 results of 12
Refine Results
  1. 1

    AC/DC harmonic interactions in the presence of GIC for the Quebec-New England Phase II HVDC transmission by Dickmander, D.L., Lee, S.Y., Desilets, G.L., Granger, M.

    Published in IEEE transactions on power delivery (01-01-1994)
    “…During the spring of 1991, several severe geomagnetic disturbances were recorded in North America, and particularly in Northern Quebec, where Hydro-Quebec's La…”
    Get full text
    Journal Article
  2. 2

    Analysis of DC harmonics using the three-pulse model for the Intermountain Power Project HVDC transmission by Dickmander, D.L., Peterson, K.J.

    Published in IEEE transactions on power delivery (01-04-1989)
    “…The authors compare the 'classical' converter modeling technique described by E.W. Kimbark (1971) and the recently proposed three-pulse model described by N.L…”
    Get full text
    Journal Article Conference Proceeding
  3. 3

    Potential DC system support to enhance AC system performance in the Western United States by Lee, R.L., Melvold, D.J., Szumlas, D.J., Le, L.M., Finley, A.T., Martin, D.E., Wong, W.K., Dickmander, D.L.

    Published in IEEE transactions on power systems (01-02-1993)
    “…The potentials of utilizing the controllability of DC lines to reduce the complexity of remedial schemes or to increase the stability performance of a system…”
    Get full text
    Journal Article
  4. 4

    Increasing WSCC power system performance with modulation controls on the Intermountain Power Project HVDC system by Martin, D.E., Wong, W.K., Dickmander, D.L., Lee, R.L., Melvold, D.J.

    Published in IEEE transactions on power delivery (01-07-1992)
    “…The interconnected power system in the western US and Canada, designated as the Western Systems Coordinating Council (WSCC), has two DC lines that transmit…”
    Get full text
    Journal Article
  5. 5

    Control system design and performance verification for the Chester, Maine static VAr compensator by Dickmander, D.L., Thorvaldsson, B.H., Stromberg, G.A., Osborn, D.L., Poitras, A.E., Fisher, D.A.

    Published in IEEE transactions on power delivery (01-07-1992)
    “…The Chester SVC (static VAr compensator) has been installed at the Chester 345 kV station in the Maine Electric Power Company operating area. Because of the…”
    Get full text
    Journal Article
  6. 6
  7. 7

    Analysis of DC Harmonics Using the Three-Pulse Model for the Intermountain Power Project HVDC Transmission by Dickmander, D. L., Peterson, K. J.

    Published in IEEE power engineering review (01-04-1989)
    “…The harmonic analysis of the dc-side of an HVDC line transmission requires realistic models of the converters, the dc line, and other relevant equipment. These…”
    Get full text
    Journal Article
  8. 8
  9. 9
  10. 10
  11. 11

    Integration of large wind farms into utility grids (part 2 - performance issues) by Pourbeik, P., Koessler, R.J., Dickmander, D.L., Wong, W.

    “…This paper presents a discussion of the two major types of wind turbines, conventional induction generators and double-fed induction machines. Performance…”
    Get full text
    Conference Proceeding
  12. 12

    Increasing WSCC power system performance with modulation controls on the Intermountain Power Project HVDC system by Martin, D.E., Wong, W.K., Dickmander, D.L., Lee, R., Melvold, D.J.

    “…The interconnected power system in the western US and Canada, the Western Systems Coordinating Council (WSCC), has two DC lines that transmit power for long…”
    Get full text
    Conference Proceeding