Search Results - "DE MELLO, F. P"
-
1
ATL‐1, an analogue of aspirin‐triggered lipoxin A4, is a potent inhibitor of several steps in angiogenesis induced by vascular endothelial growth factor
Published in British journal of pharmacology (01-03-2008)“…Background and purpose: Vascular endothelial growth factor (VEGF) is the most important proangiogenic protein. We have demonstrated that ATL‐1, a synthetic…”
Get full text
Journal Article -
2
Activity of synthetic chalcones in hamsters experimentally infected with Leishmania (Viannia) braziliensis
Published in Parasitology research (1987) (01-10-2015)“…The purpose of this study is to evaluate the toxicity of synthetic chalcones 1 and 2 in uninfected hamsters and anti-Leishmania activity of synthetic chalcones…”
Get full text
Journal Article -
3
Ultrastructural and morphological changes in Leishmania (Viannia) braziliensis treated with synthetic chalcones
Published in Experimental parasitology (01-01-2016)“…Cutaneous leishmaniasis has an estimated incidence of 1.5 million new cases per year and the treatment options available are old, expensive, toxic, and…”
Get full text
Journal Article -
4
Boiler models for system dynamic performance studies
Published in IEEE transactions on power systems (01-02-1991)“…The dynamic response of boiler pressure is a mass-volume-energy balance relationship which can be derived from changes in turbine valve position and boiler…”
Get full text
Journal Article -
5
Leishmanicidal activity of synthetic chalcones in Leishmania (Viannia) braziliensis
Published in Experimental parasitology (01-01-2014)“…•New synthetic chalcones (1–4) showed inhibitory activity in vitro to promastigotes of L. (V.) braziliensis.•All synthetic chalcones (1–4) exhibited low…”
Get full text
Journal Article -
6
Dynamic models for combined cycle plants in power system studies
Published in IEEE transactions on power systems (01-08-1994)“…The increasing use of combined cycle plants as part of a power system's generation mix brings an industry need for modeling these types of plants in…”
Get full text
Journal Article -
7
Representation of Saturation in Synchronous Machines
Published in IEEE transactions on power systems (1986)“…Prediction of synchronous machine steady state and transient performance requires proper account of iron saturation effects. This paper explores, with…”
Get full text
Journal Article Conference Proceeding -
8
Voltage oscillatory instability caused by induction motor loads
Published in IEEE transactions on power systems (01-08-1996)“…Isolated power systems which fit the structure of a single equivalent generator supplying an equivalent composite load can experience a voltage oscillatory…”
Get full text
Journal Article -
9
Mechanical countermeasures to subsynchronous torsional instability (in turbogenerators)
Published in IEEE transactions on power systems (01-11-1990)“…A mechanical countermeasure is presented that uses a fluid coupling to drive a flywheel at the end of a turbogenerator shaft, resulting in increased torsional…”
Get full text
Journal Article Conference Proceeding -
10
Exploratory concepts on control of variable series compensation in transmission systems to improve damping of intermachine/system oscillations
Published in IEEE transactions on power systems (01-02-1994)“…Of much current interest is the application of power electronics in AC transmission systems notably to control power flow in series elements through variable…”
Get full text
Journal Article -
11
Determination of synchronous machine stator and field leakage inductances from standstill frequency response tests
Published in IEEE transactions on power systems (01-11-1988)“…It is shown that the identification of d-axis stator and field winding leakage inductance appears to be possible using standstill frequency-response rests with…”
Get full text
Journal Article Conference Proceeding -
12
Steam plant startup and control in system restoration
Published in IEEE transactions on power systems (01-02-1994)“…The IEEE Working Group on Power System Restoration developed a panel session for the Summer Power Meeting on July 14, 1992 on Special Considerations in Power…”
Get full text
Journal Article -
13
Aspirin-triggered Lipoxin A4 inhibition of VEGF-induced endothelial cell migration involves actin polymerization and focal adhesion assembly
Published in Oncogene (05-01-2006)“…Angiogenesis, the growth of new capillaries from pre-existing ones, occurs through dynamic functions of the endothelial cells (EC), including migration, which…”
Get full text
Journal Article -
14
ATL‐1, an analogue of aspirin‐triggered lipoxin A 4 , is a potent inhibitor of several steps in angiogenesis induced by vascular endothelial growth factor
Published in British journal of pharmacology (29-01-2009)“…Background and purpose: Vascular endothelial growth factor (VEGF) is the most important proangiogenic protein. We have demonstrated that ATL‐1, a synthetic…”
Get full text
Journal Article -
15
Aspirin-triggered Lipoxin A sub(4) inhibition of VEGF-induced endothelial cell migration involves actin polymerization and focal adhesion assembly
Published in Oncogene (01-01-2006)“…Angiogenesis, the growth of new capillaries from pre-existing ones, occurs through dynamic functions of the endothelial cells (EC), including migration, which…”
Get full text
Journal Article -
16
Harmonic interaction in generator pre-sunchronous operation
Published in 2012 IEEE International Conference on Power System Technology (POWERCON) (01-10-2012)“…The pre-synchronous condition of generators operating at normal speed, with voltage on manual control, while connected to open circuited step up transformers,…”
Get full text
Conference Proceeding -
17
Simulating fast and slow dynamic effects in power systems
Published in IEEE computer applications in power (01-07-1992)“…Different numerical techniques for power system dynamic simulation are described. Examples of large-scale system simulations using the extended term simulation…”
Get full text
Journal Article -
18
Measurement of synchronous machine rotor angle from analysis of zero sequence harmonic components of machine terminal voltage
Published in IEEE transactions on power delivery (01-10-1994)“…Generator rotor angle measurement is useful in identification of electric machine parameters in the d and q axes and as an indicator of stability of the…”
Get full text
Journal Article -
19
Some considerations in the development of restoration plans for electric utilities serving large metropolitan areas
Published in IEEE transactions on power systems (01-05-2006)“…The objective of this paper is to establish general guidelines on the considerations and needs in the development of effective restoration plans for electric…”
Get full text
Journal Article -
20
Practical Approaches to Supplementary Stabilizing from Accelerating Power
Published in IEEE transactions on power apparatus and systems (01-09-1978)“…Use of accelerating power to provide damping of synchronous machine oscillations through supplementary control of excitation has significant advantages…”