Search Results - "DAURES, Josiane"
-
1
Accuracy of a dose-area product compared to an absorbed dose to water at a point in a 2 cm diameter field
Published in Medical physics (Lancaster) (01-07-2016)“…Purpose: Graphite calorimeters with a core diameter larger than the beam can be used to establish dosimetric references in small fields. The dose-area product…”
Get full text
Journal Article -
2
Proton dosimetry comparison involving ionometry and calorimetry
Published in International journal of radiation oncology, biology, physics (01-02-1997)“…A comparison of the absorbed dose to tissue determined by various ionization chambers, Faraday cups, and an A-150 plastic calorimeter was performed in the 200…”
Get more information
Journal Article -
3
Using a dose-area product for absolute measurements in small fields: a feasibility study
Published in Physics in medicine & biology (21-01-2016)“…To extend the dosimetric reference system to field sizes smaller than 2 cm × 2 cm, the LNE-LNHB laboratory is studying an approach based on a new dosimetric…”
Get more information
Journal Article -
4
The LNE-LNHB water calorimeter for primary measurement of absorbed dose at low depth in water: application to medium-energy x-rays
Published in Physics in medicine & biology (07-05-2013)“…Water calorimeters are used to establish absorbed dose standards in several national metrology laboratories involved in ionizing radiation dosimetry. These…”
Get more information
Journal Article -
5
Comparison between absorbed dose to water standards established by water calorimetry at the LNE-LNHB and by application of international air-kerma based protocols for kilovoltage medium energy x-rays
Published in Physics in medicine & biology (07-05-2013)“…Nowadays, the absorbed dose to water for kilovoltage x-ray beams is determined from standards in terms of air-kerma by application of international dosimetry…”
Get more information
Journal Article -
6
Feasibility of using a dose-area product ratio as beam quality specifier for photon beams with small field sizes
Published in Physica medica (01-01-2018)“…•DAPR20,10 properties are investigated in photon beams with field sizes below 2 cm.•Influence of field size on photon spectrum and dosimetric parameters is…”
Get full text
Journal Article -
7
FIRST EURADOS INTERCOMPARISON EXERCISE OF EYE LENS DOSEMETERS FOR MEDICAL APPLICATIONS
Published in Radiation protection dosimetry (01-09-2016)“…In the context of the decrease in the eye lens dose limit for occupational exposure to 20 mSv per year stated by the recent revision of the European Basic…”
Get full text
Journal Article Publication -
8
High energy photon reference for radiation protection: technical design of the LINAC beam and ionization chambers; and calculation of monoenergetic conversion coefficients
Published in EPJ Web of Conferences (01-01-2016)“…In this work, we present the results of the first part of a research project aimed at offering a complete response to dosimeters providers and nuclear…”
Get full text
Journal Article Conference Proceeding -
9
Air kerma to HP(3) conversion coefficients for photons from 10 keV to 10 MeV, calculated in a cylindrical phantom
Published in Radiation protection dosimetry (01-05-2013)“…In the framework of the ORAMED project (Optimization of RAdiation protection for MEDical staff), funded by the European Union Seventh Framework Programme,…”
Get full text
Journal Article -
10
Intercomparison of active personal dosemeters in interventional radiology
Published in Radiation protection dosimetry (2008)“…The use of active personal dosemeters (APD) in interventional radiology was evaluated by Working Group 9 (Radiation protection dosimetry of medical staff) of…”
Get full text
Journal Article -
11
Intercomparison on measurements of the quantity personal dose equivalent, Hp(0.07), by extremity ring dosimeters in medical fields
Published in Radiation measurements (01-02-2008)“…In the framework of the CONRAD project, the EURADOS WG9 organized an intercomparison of extremity dosimeters that are used in a variety of medical fields. The…”
Get full text
Conference Proceeding Journal Article -
12
Traceability of absorbed dose in photon radiation therapy: from primary standard to patient treatment
Published in Accreditation and quality assurance (01-11-2009)“…The relevant standard quantity for radiation therapy is the absorbed dose to water. This quantity refers to the amount of energy locally absorbed in a small…”
Get full text
Journal Article -
13