Search Results - "DAUGIRDAS, John"

Refine Results
  1. 1
  2. 2

    Comparison of measured vs kinetic-model predicted phosphate removal during hemodialysis and hemodiafiltration by Daugirdas, John T

    Published in Nephrology, dialysis, transplantation (23-11-2022)
    “…To what extent hemodiafiltration (HDF) improves management of hyperphosphatemia over hemodialysis (HD) is a subject of ongoing investigation. We modified a…”
    Get full text
    Journal Article
  3. 3

    Kt/V (and especially its modifications) remains a useful measure of hemodialysis dose by Daugirdas, John T

    Published in Kidney international (01-09-2015)
    “…Removal of small molecular weight solutes shows a strong relationship to hemodialysis outcomes. In contrast, survival with high-flux dialysis or…”
    Get more information
    Journal Article
  4. 4
  5. 5

    Comparison of modeled versus reported phosphate removal and modeled versus postdialysis serum phosphate levels in conventional hemodialysis by Daugirdas, John T.

    Published in Seminars in dialysis (01-07-2023)
    “…Background We compared predictions of phosphate removal by a 2‐pool kinetic model with measured phosphate removal in spent dialysate as reported by others…”
    Get full text
    Journal Article
  6. 6

    Lower cardiovascular mortality with high-volume hemodiafiltration: a cool effect? by Daugirdas, John T

    Published in Nephrology, dialysis, transplantation (01-06-2016)
    “… It is likely that high-convective volume hemodiafiltration results in better cardiovascular outcomes than hemodialysis. At the moment, the mechanism of…”
    Get full text
    Journal Article
  7. 7

    A two-pool kinetic model predicts phosphate concentrations during and shortly following a conventional (three times weekly) hemodialysis session by Daugirdas, John T

    Published in Nephrology, dialysis, transplantation (01-01-2018)
    “…Previous studies have suggested that a conventional two-pool model cannot be used to predict intradialysis and early postdialysis phosphorus concentrations. A…”
    Get full text
    Journal Article
  8. 8
  9. 9

    Solute solver 'what if' module for modeling urea kinetics by Daugirdas, John T

    Published in Nephrology, dialysis, transplantation (01-11-2016)
    “…The publicly available Solute Solver module allows calculation of a variety of two-pool urea kinetic measures of dialysis adequacy using pre- and postdialysis…”
    Get full text
    Journal Article
  10. 10

    Intradialytic hypotension and splanchnic shifting: Integrating an overlooked mechanism with the detection of ischemia‐related signals during hemodialysis by Daugirdas, John T.

    Published in Seminars in dialysis (01-05-2019)
    “…In the most simple analysis, a patient's hematocrit during hemodialysis will rise when the rate of ultrafiltration exceeds the rate at which the fluid is…”
    Get full text
    Journal Article
  11. 11

    Hemodialysis effect on platelet count and function and hemodialysis-associated thrombocytopenia by Daugirdas, John T, Bernardo, Angelito A

    Published in Kidney international (01-07-2012)
    “…Substantial activation of platelets can occur in the course of hemodialysis. Platelet surface markers show evidence of platelet degranulation. Some activation…”
    Get more information
    Journal Article
  12. 12

    Equations to Estimate the Normalized Creatinine Generation Rate (CGRn) in 3/Week Dialysis Patients With or Without Residual Kidney Function by Daugirdas, John T.

    Published in Journal of renal nutrition (01-01-2021)
    “…Normalized creatinine generation rate (CGRn) can be computed for a variety of dialysis schedules using a recently described kinetic modeling program. However,…”
    Get full text
    Journal Article
  13. 13
  14. 14
  15. 15

    Removal of Phosphorus by Hemodialysis by Daugirdas, John T.

    Published in Seminars in dialysis (01-11-2015)
    “…The control of serum phosphorus by dialysis is made difficult by the fact that intradialytic blood levels tend to be low, and because phosphorus is removed…”
    Get full text
    Journal Article
  16. 16

    Eliminating the need for routine monthly postdialysis serum urea nitrogen measurement: A method for monitoring Kt/V and normalized protein catabolic rate using conductivity determined dialyzer clearance by Daugirdas, John T.

    Published in Seminars in dialysis (01-11-2018)
    “…Many dialysis machines can compute dialyzer sodium clearances at multiple time points during a dialysis treatment using conductivity. For a given treatment,…”
    Get full text
    Journal Article
  17. 17
  18. 18
  19. 19

    Dialysis time, survival, and dose-targeting bias by Daugirdas, John T

    Published in Kidney international (01-01-2013)
    “…Dialysis time is increasingly being appreciated as an important measure of dialysis adequacy. Increased dialysis time leads to better control of volume excess,…”
    Get more information
    Journal Article
  20. 20

    Hemodialysis Treatment Time: As Important as it Seems? by Daugirdas, John T.

    Published in Seminars in dialysis (01-03-2017)
    “…Hemodialysis treatment time and Kt/V can both be considered to be primary measures of hemodialysis adequacy, because when either goes to zero, mortality is…”
    Get full text
    Journal Article