Search Results - "Croci, Tommaso"
-
1
TCAD Modeling of Surface Radiation Damage Effects: A State-Of-The-Art Review
Published in Frontiers in physics (02-02-2021)“…A comprehensive numerical model which accounts for surface damage effects induced by radiation on silicon particle detectors is presented with reference to the…”
Get full text
Journal Article -
2
TCAD modeling of bulk radiation damage effects in silicon devices with the Perugia radiation damage model
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-10-2022)“…The “Perugia Surface and Bulk” radiation damage model is a Synopsys Sentaurus Technology CAD (TCAD) numerical model which accounts for surface and bulk damage…”
Get full text
Journal Article -
3
Characterisation of the FBK EXFLU1 thin sensors with gain in a high fluence environment
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-11-2024)“…The EXFLU1 batch of LGAD sensors on substrates of thickness between 15 and 45μm were exposed to various radiation grades between 1 × 1014 and 5 × 1015 neqcm−2…”
Get full text
Journal Article -
4
Dosimetry of microbeam radiotherapy by flexible hydrogenated amorphous silicon detectors
Published in Physics in medicine & biology (26-07-2024)“…Detectors that can provide accurate dosimetry for microbeam radiation therapy (MRT) must possess intrinsic radiation hardness, a high dynamic range, and a…”
Get more information
Journal Article -
5
A hydrogenated amorphous silicon detector for Space Weather applications
Published in Astrophysics and space science (01-09-2023)“…The characteristics of a hydrogenated amorphous silicon (a-Si:H) detector are presented here for monitoring in space solar flares and the evolution of strong…”
Get full text
Journal Article -
6
TCAD modelling of a-Si:H devices for particle detection applications
Published in Materials science in semiconductor processing (01-01-2024)“…Hydrogenated amorphous silicon (a-Si:H) has been proposed as a suitable material for particle detection applications thanks to its property to be deposited…”
Get full text
Journal Article -
7
A Front-End Circuit in 28 nm CMOS for Hydrogenated Amorphous Silicon Detectors in Clinical Dosimetry
Published in 2024 13th International Conference on Modern Circuits and Systems Technologies (MOCAST) (26-06-2024)“…This paper presents the design and the charac-terization of a front-end circuit, designed in 28 nm CMOS, for real-time dosimetry in radiation diagnostics and…”
Get full text
Conference Proceeding -
8
A Compensated Design of the LGAD Gain Layer
Published 01-09-2022“…Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Volume 1040, 2022, 167232 In…”
Get full text
Journal Article -
9
A Hydrogenated amorphous silicon detector for Space Weather Applications
Published 01-02-2023“…The characteristics of a hydrogenated amorphous silicon (a-Si:H) detector are presented here for monitoring in space solar flares and the evolution of large…”
Get full text
Journal Article -
10
Depleted MAPS on a 110 nm CMOS CIS Technology
Published in 2019 26th IEEE International Conference on Electronics, Circuits and Systems (ICECS) (01-11-2019)“…A high-voltage monolithic active pixel sensor, designed to be compatible with standard deep sub-micron CMOS production lines, is described. The device can…”
Get full text
Conference Proceeding