Longitudinal Evaluation of Radiopacity of Resin Composites: Influence of Photoactivation and Accelerated Photoaging

This study aimed to assess longitudinally the radiopacity of resin composites under the influence of photoactivation and photoaging processes. Ten specimens (1 mm thick and 4 mm in diameter) of three different microhybrid resin composites, Filtek Z250 XT (R1), TPH 3 Spectrum (R2), and Opallis (R3),...

Full description

Saved in:
Bibliographic Details
Published in:Operative dentistry Vol. 43; no. 2; pp. E64 - E71
Main Authors: Cruz, A D, Costa, Iam, Calazans, F S, Aguiar, M F, Barceleiro, M O
Format: Journal Article
Language:English
Published: United States 01-03-2018
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:This study aimed to assess longitudinally the radiopacity of resin composites under the influence of photoactivation and photoaging processes. Ten specimens (1 mm thick and 4 mm in diameter) of three different microhybrid resin composites, Filtek Z250 XT (R1), TPH 3 Spectrum (R2), and Opallis (R3), were prepared for this study. For longitudinal assessment of radiopacity, radiographic images were obtained five times. The first time (T1), the specimens were not photoactivated; the second time (T2), the specimens were photoactivated; and the next three times, photoaging was carried out, with images obtained at 24 hours (T3), 48 hours (T4), and 72 hours (T5) after this process. The photoaging was conducted using LED light (700 lumens, 9 W, 6400 k) under controlled environmental conditions at 37°C (±1°C) and 65% (±5%) relative humidity. The digital system DIGORA Optime was used. The digital images were measured using the histogram function, and then the pixel intensity values were converted into mmAl (the standard unit of radiopacity) using a linear regression function, with minimal adjustment of R ≥ 0.9. Data in mmAl were statistically analyzed using an analysis of variance (α=0.05). R2 resin composite showed higher values of radiopacity, R1 resin composite showed intermediate values, and R3 resin composite showed lower values. Only at T1 did the higher radiopacity of R2 composite differ significantly from other groups ( p = 0.0000). After application of treatments (photoactivation and photoaging), all radiopacity values were similar ( p-values to T2=0.0507, T3=0.0536, T4=0.0502, T5=0.0501) due to consecutive increase of radiopacity of R1 and R3 composites from T2. Photoactivation and photoaging processes influenced the radiopacity, but changes occurring in the degree of radiopacity were dependent on the composition and chemical characteristics of each composite used.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0361-7734
1559-2863
DOI:10.2341/16-240-L