Search Results - "Colella, Pietro"
-
1
Thermal Assessment of Power Cables and Impacts on Cable Current Rating: An Overview
Published in Energies (Basel) (13-10-2020)“…The conceptual assessment of the rating conditions of power cables was addressed over one century ago, with theories based on the physical and heat transfer…”
Get full text
Journal Article -
2
The Immediate Impacts of COVID-19 on European Electricity Systems: A First Assessment and Lessons Learned
Published in Energies (Basel) (01-01-2021)“…The worldwide spread of the COVID-19 pandemic in 2020 forced most countries to intervene with policies and actions—including lockdowns, social-distancing and…”
Get full text
Journal Article -
3
Concepts and Methods to Assess the Dynamic Thermal Rating of Underground Power Cables
Published in Energies (Basel) (01-05-2021)“…With the increase in the electrical load and the progressive introduction of power generation from intermittent renewable energy sources, the power line…”
Get full text
Journal Article -
4
Impact of Wind and Solar Generation on the Italian Zonal Electricity Price
Published in Energies (Basel) (01-09-2021)“…This paper assesses the impact of increasing wind and solar power generation on zonal market prices in the Italian electricity market from 2015 to 2019,…”
Get full text
Journal Article -
5
Impacts of COVID-19 Pandemic on Italian Electricity Demand and Markets
Published in CSEE Journal of Power and Energy Systems (01-03-2023)Get full text
Journal Article -
6
Model-Based Identification of Alternative Bidding Zones: Applications of Clustering Algorithms with Topology Constraints
Published in Energies (Basel) (01-05-2021)“…The definition of bidding zones is a relevant question for electricity markets. The bidding zones can be identified starting from information on the nodal…”
Get full text
Journal Article -
7
Creation of the Internal Categories for Low-Voltage Three-Phase Electricity Users
Published in IEEE transactions on industry applications (01-07-2024)“…The categorisation of electricity users is carried out by Distributor System Operators (DSOs) and retailers to create synthetic load profiles. Initially, some…”
Get full text
Journal Article -
8
Fault Current Detection and Dangerous Voltages in DC Urban Rail Traction Systems
Published in IEEE transactions on industry applications (01-07-2017)“…In this paper, the electrical safety of dc urban traction systems is analyzed, with particular focus on fault current detection and on dangerous voltages which…”
Get full text
Journal Article -
9
A Comparative Review of the Methodologies to Identify a Global Earthing System
Published in IEEE transactions on industry applications (01-07-2017)“…International Standards IEC 61936-1 and EN 50522 define a global earthing system (GES) as the earthing network, created by the interconnection of local…”
Get full text
Journal Article -
10
Forecasting Electricity Price in Different Time Horizons: An Application to the Italian Electricity Market
Published in IEEE transactions on industry applications (01-11-2021)“…Electricity price is a crucial element for market players to maximize their profits. In this context, the forecast of the hour-ahead, day-ahead, and week-ahead…”
Get full text
Journal Article -
11
Impact of MV Ground Fault Current Distribution on Global Earthing Systems
Published in IEEE transactions on industry applications (01-11-2015)“…Global earthing systems (GESs), created by the interconnection of local earthing systems, should guarantee the absence of dangerous touch voltages. One of the…”
Get full text
Journal Article -
12
Validation and Testing of an Analytical Formulation to Compute the Reduction Factor in MV Grids
Published in IEEE transactions on industry applications (01-07-2020)“…Global Earthing Systems (GESs) are defined by International Standards IEC 61936-1 and EN 50522 as an equivalent Earthing System (ES) created by the…”
Get full text
Journal Article -
13
Optimization of Digital Overcurrent Protection Settings in DC Urban Light Railway Systems
Published in IEEE transactions on industry applications (01-07-2019)“…DC urban light railway systems are used for public transportation in many towns worldwide. In these systems, short-circuit currents are often similar, both in…”
Get full text
Journal Article -
14
Dangerous touch voltages in buildings: The impact of extraneous conductive parts in risk mitigation
Published in Electric power systems research (01-06-2017)“…[Display omitted] •Reinforced concrete and brick buildings are modeled with FEM.•Touch voltage reduction due to embedded metallic parts is quantitatively…”
Get full text
Journal Article -
15
Data analytics in the electricity market: a systematic literature review
Published in Energy systems (Berlin. Periodical) (08-04-2023)Get full text
Journal Article -
16
Global Earthing System: Can Buried Metallic Structures Significantly Modify the Ground Potential Profile?
Published in IEEE transactions on industry applications (01-11-2015)“…Global earthing systems (GESs), which are created by the interconnection of local earthing systems, should guarantee the absence of dangerous touch voltages…”
Get full text
Journal Article -
17
Ground Resistance of Buried Metallic Parts in Urban Areas: An Extensive Measurement Campaign
Published in IEEE transactions on industry applications (01-11-2017)“…In urban and industrial areas, a relevant presence of buried metallic objects (e.g., gas and water pipes, etc.) can be detected. Usually, these elements are…”
Get full text
Journal Article -
18
Fall of Potential Measurement of the Earth Resistance in Urban Environments: Accuracy Evaluation
Published in IEEE transactions on industry applications (01-05-2019)“…Both Standards EN 50522 and IEEE 81 propose the fall of potential method (FPM) to carry out the measurement of the resistance to earth…”
Get full text
Journal Article -
19
Risk of electrocution during fire suppression activities involving photovoltaic systems
Published in Fire safety journal (01-07-2014)“…Firefighting activities regarding buildings normally require electric power to be disconnected before a water jet is used, in order to minimize the risk of…”
Get full text
Journal Article -
20
Currents Distribution During a Fault in an MV Network: Methods and Measurements
Published in IEEE transactions on industry applications (01-11-2016)“…When a single line to ground fault (SLGF) happens on the MV side of an HV/MV system, only a small portion of the fault current is injected into the ground by…”
Get full text
Journal Article