Search Results - "Cluitmans, Pierre J. M"
-
1
Resting-state networks and dissociation in psychogenic non-epileptic seizures
Published in Journal of psychiatric research (01-07-2014)“…Abstract Objective Psychogenic non-epileptic seizures (PNES) are epilepsy-like episodes which have an emotional rather than organic origin. Although PNES have…”
Get full text
Journal Article -
2
Time-Frequency Analysis of Accelerometry Data for Detection of Myoclonic Seizures
Published in IEEE transactions on information technology in biomedicine (01-09-2010)“…Four time-frequency and time-scale methods are studied for their ability of detecting myoclonic seizures from accelerometric data. Methods that are used are:…”
Get full text
Journal Article -
3
investigation of the phase locking index for measuring of interdependency of cortical source signals recorded in the EEG
Published in Biological cybernetics (01-02-2009)“…The phase locking index (PLI) was introduced to quantify in a statistical sense the phase synchronization of two signals. It has been commonly used to process…”
Get full text
Journal Article -
4
Autonomic nervous system functioning associated with psychogenic nonepileptic seizures: Analysis of heart rate variability
Published in Epilepsy & behavior (01-01-2016)“…Abstract Objective Psychogenic nonepileptic seizures (PNESs) resemble epileptic seizures but originate from psychogenic rather than organic causes. Patients…”
Get full text
Journal Article -
5
Neurophysiological correlates of dissociative symptoms
Published in Journal of Neurology, Neurosurgery and Psychiatry (01-02-2014)“…Objective Dissociation is a mental process with psychological and somatoform manifestations, which is closely related to hypnotic suggestibility and…”
Get full text
Journal Article Book Review -
6
Detection of Subtle Nocturnal Motor Activity From 3-D Accelerometry Recordings in Epilepsy Patients
Published in IEEE transactions on biomedical engineering (01-11-2007)“…This paper presents a first step towards reliable detection of nocturnal epileptic seizures based on 3-D accelerometry (ACM) recordings. The main goal is to…”
Get full text
Journal Article -
7
Epileptic seizure detection on patients with mental retardation based on EEG features: A pilot study
Published in 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (01-08-2015)“…Mental retardation (MR) is one of the most common secondary disabilities in people with Epilepsy. However, to our knowledge there are no reliable seizure…”
Get full text
Conference Proceeding Journal Article -
8
Seizure detection using dynamic warping for patients with intellectual disability
Published in 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (01-08-2016)“…Electroencephalography (EEG) is paramount for both retrospective analysis and real-time monitoring of epileptic seizures. Studies have shown that EEG-based…”
Get full text
Conference Proceeding Journal Article -
9
Sympathetic activity and hypothalamo-pituitary–adrenal axis activity during sleep in post-traumatic stress disorder: A study assessing polysomnography with simultaneous blood sampling
Published in Psychoneuroendocrinology (01-01-2013)“…Summary Background Nightmares and insomnia in PTSD are hallmark symptoms, yet poorly understood in comparison to the advances toward a biological framework for…”
Get full text
Journal Article -
10
The potential value of three-dimensional accelerometry for detection of motor seizures in severe epilepsy
Published in Epilepsy & behavior (01-08-2005)“…Seizure detection results based on the visual analysis of three-dimensional (3D) accelerometry (ACM) and video/EEG recordings are reported for 18 patients with…”
Get full text
Journal Article -
11
Model for arm movements during myoclonic seizures
Published in 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (01-01-2007)“…A model is formulated for arm movements during myoclonic (epileptic) seizures. The system described in the model, consists of a mechanical and an…”
Get full text
Conference Proceeding Journal Article -
12
Clinical evaluation of a method for automatic detection and removal of artifacts in auditory evoked potential monitoring
Published in Journal of clinical monitoring (01-11-1995)“…The objective of our study was to evaluate the method for detection and removal of artifacts in evoked potential monitoring described earlier by Cluitmans and…”
Get more information
Journal Article -
13
Sympathetic activity and hypothalamo-pituitaryaadrenal axis activity during sleep in post-traumatic stress disorder: A study assessing polysomnography with simultaneous blood sampling
Published in Psychoneuroendocrinology (01-01-2013)“…Nightmares and insomnia in PTSD are hallmark symptoms, yet poorly understood in comparison to the advances toward a biological framework for the disorder…”
Get full text
Journal Article -
14
Artifact detection and removal during auditory evoked potential monitoring
Published in Journal of clinical monitoring (01-04-1993)“…Various artifacts can distort or obscure evoked potential waveforms. The algorithms presented in this paper scan the output electroencephalographic signal for…”
Get more information
Journal Article -
15
Optimized moving-average filtering for gradient artefact correction during simultaneous EEG-fMRI
Published in 5th ISSNIP-IEEE Biosignals and Biorobotics Conference (2014): Biosignals and Robotics for Better and Safer Living (BRC) (01-05-2014)“…The strong capability of the combined EEG-fMRI for investigating and revealing new insights on mapping of the brain activity as well as on several other…”
Get full text
Conference Proceeding -
16
Context related artefact detection in prolonged EEG recordings
Published in Computer methods and programs in biomedicine (01-11-1999)“…The need for reliable detection of artefacts in raw and processed EEG is widely acknowledged. Although different EEG analysis systems have been described, only…”
Get full text
Journal Article -
17
Separation of Spatially Localized Cortical Activities in the EEG: Model-based Analysis and Optimization
Published in 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (01-01-2007)“…The mapping of brain sources into the scalp electroencephalogram (EEG) depends on volume conduction properties of the head and on an electrode montage…”
Get full text
Conference Proceeding Journal Article -
18
Analysis of the Phase Locking Index for Measuring of Interdependency of Cortical Signals Recorded in the EEG
Published in 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (01-01-2007)“…The phase locking index (PLI) was introduced to quantify in a statistical sense the phase synchronization of two signals. It has been commonly used to process…”
Get full text
Conference Proceeding Journal Article