Search Results - "Ciano, S"
-
1
Silicon Photomultipliers as a Readout System for a Scintillator-Lead Shashlik Calorimeter
Published in IEEE transactions on nuclear science (01-06-2011)“…Silicon photomultipliers are silicon devices that in recent times have been proposed as candidates for the replacement of photomultiplier tubes in many…”
Get full text
Journal Article -
2
The XAFS fluorescence detector system based on 64 silicon drift detectors for the SESAME synchrotron light source
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-08-2019)“…SESAME (Synchrotron-light for Experimental Science and Application in the Middle East) is a “third-generation” synchrotron light source. The Middle East’s…”
Get full text
Journal Article -
3
Macrophage migration in fibrin gel matrices. II. Effects of clotting factor XIII, fibronectin, and glycosaminoglycan content on cell migration
Published in The Journal of immunology (1950) (01-04-1988)“…We investigated the migration of oil-induced, guinea pig peritoneal macrophages in three-dimensional fibrin matrices, with particular attention to variables…”
Get full text
Journal Article -
4
Macrophage migration in fibrin gel matrices
Published in Laboratory investigation (01-01-1986)“…Macrophage migration has been extensively studied in vitro on artificial substrates but in vivo macrophages migrate through connective tissue and fibrin gel…”
Get more information
Journal Article -
5
Silicon photomultipliers for scintillating trackers
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-12-2012)“…In recent years, silicon photomultipliers (SiPMs) have been proposed as a new kind of readout device for scintillating detectors in many experiments. A SiPM…”
Get full text
Journal Article -
6
Segmental colitis associated with Aeromonas hydrophila
Published in The American journal of gastroenterology (01-04-1989)“…We describe a 40-yr-old woman who presented with abdominal pain and diarrhea, and who was found to have segmental colitis involving the cecum and ascending…”
Get more information
Journal Article -
7
A signet-ring cell carcinoma of the ampulla of Vater
Published in Archives of pathology & laboratory medicine (1976) (01-10-1990)“…We describe a variant of carcinoma of the ampulla of Vater, which, to our knowledge, has not been previously described. Classic signet-ring cells represented…”
Get more information
Journal Article -
8
Quantitation of lymphocytes in endomyocardial biopsies: use and limitations of antibodies to leukocyte common antigen
Published in Human pathology (01-08-1987)“…The difficulty in distinguishing lymphocytes from other cells in the myocardial interstitium on hematoxylin-eosin-stained sections has contributed to the…”
Get more information
Journal Article -
9
Acquired immunodeficiency syndrome with disseminated toxoplasmosis presenting as an acute pulmonary and gastrointestinal illness
Published in Archives of pathology & laboratory medicine (1976) (01-05-1991)“…Encephalitis due to the protozoan Toxoplasma gondii has emerged as a common cause of central nervous system disease in patients with acquired immunodeficiency…”
Get more information
Journal Article -
10
Villous adenoma presenting as a vaginal polyp in a rectovaginal tract
Published in Human pathology (01-08-1987)“…A 72-year-old woman had a villous adenoma of endodermal derivation involving the rectovaginal septum and contiguous mucosal surfaces that presented clinically…”
Get more information
Journal Article -
11
Lactic Acidosis Associated with Linezolid Treatment: Cases Notified to the French Pharmacovigilance Network
Published in Drug safety (2006)Get full text
Journal Article -
12
A SiPM based readout system for shashlik calorimeters: Status and perspectives
Published in 2011 IEEE Nuclear Science Symposium Conference Record (01-10-2011)“…In recent years Silicon Photomultipliers (SiPMs) have been proposed as a new type of readout system for scintillating detectors in many experiments. SiPMs…”
Get full text
Conference Proceeding -
13
Development and tests of a new prototype detector for the XAFS beamline at Elettra Synchrotron in Trieste
Published 12-01-2016“…The XAFS beamline at Elettra Synchrotron in Trieste combines X-ray absorption spectroscopy and X-ray diffraction to provide chemically specific structural…”
Get full text
Journal Article -
14
Tracking Patterns of Nonadherence to Prescribed CT Protocol Parameters
Published in Journal of the American College of Radiology (01-02-2017)“…Abstract Purpose Quantification of the frequency, understanding the motivation, and documentation of the changes made by CT technologists at scan time are…”
Get full text
Journal Article -
15
A Wiki-Based Solution to Managing Your Institution’s Imaging Protocols
Published in Journal of the American College of Radiology (01-07-2016)Get full text
Journal Article -
16
Simultaneous laparoscopic removal of a Todani type II choledochal cyst and a microlithiasic cholecystitis
Published in Annals of hepato-biliary-pancreatic surgery (2022)“…Diverticula of the choledochus, better known as Todani type II cysts, are very rare and represent a predominantly pediatric pathology. Their identification by…”
Get full text
Journal Article