Search Results - "Choi, Charles H."
-
1
A novel technique for postclosure of large‐bore sheaths using two Perclose devices
Published in Catheterization and cardiovascular interventions (01-04-2021)“…Objectives This study aimed to assess the feasibility, efficacy, and safety of a novel percutaneous postprocedure closure technique for large arterial sheath…”
Get full text
Journal Article -
2
Comparison of paravalvular aortic leak characteristics in the Medtronic CoreValve versus Edwards Sapien Valve: Paravalvular aortic leak characteristics
Published in Catheterization and cardiovascular interventions (01-11-2018)“…Objectives Temporally quantify and localize paravalvular aortic leak (PVL) after transcatheter aortic valve replacement (TAVR) in the Medtronic CoreValve (MCV)…”
Get full text
Journal Article -
3
A comparison of valve‐in‐valve transcatheter aortic valve replacement in failed stentless versus stented surgical bioprosthetic aortic valves
Published in Catheterization and cardiovascular interventions (01-05-2019)“…Objectives The objectives of this study were to compare short‐ and intermediate‐term clinical outcomes, procedural complications, TAVR prosthesis hemodynamics,…”
Get full text
Journal Article -
4
Redo‐aortic valve replacement in prior stentless prosthetic aortic valves: Transcatheter versus surgical approach
Published in Catheterization and cardiovascular interventions (01-01-2022)“…Objectives The objective was to compare outcomes of redo‐aortic valve replacement (AVR) via surgical or transcatheter approach in prior surgical AVR with large…”
Get full text
Journal Article -
5
Comparison of outcomes with surgical cut‐down versus percutaneous transfemoral transcatheter aortic valve replacement: TAVR transfemoral access comparisons between surgical cut‐down and percutaneous approach
Published in Catheterization and cardiovascular interventions (01-06-2018)“…Objectives The objective is to compare the short‐term (30 days) and late (12 months) vascular adverse events in patients undergoing transfemoral…”
Get full text
Journal Article -
6
Transient Hypothermia in Hiv-1 with Insulin-Like Growth Factor-1 Deficiency and Severe Protein Calorie Malnutrition
Published in Proceedings - Baylor University. Medical Center (01-01-2015)“…Hypothermia is a multifactorial process that results from decreased heat production or increased heat loss, with the former due to, but not limited to,…”
Get full text
Journal Article -
7
Angiosarcoma of the Right Atrium Presenting as Hemoptysis
Published in Proceedings - Baylor University. Medical Center (01-01-2016)“…This case report describes a previously healthy 32-year-old man who presented with several weeks of hemoptysis. Initially he was treated with antibiotics with…”
Get full text
Journal Article -
8
One problem two issues! Left ventricular systolic and diastolic dysfunction in aortic stenosis
Published in Annals of translational medicine (01-01-2014)“…Reports suggested that immediate post-aortic valve replacement (AVR); left ventricular (LV) dysfunction may be an important risk for morbidity and mortality in…”
Get full text
Journal Article -
9
Iatrogenic retained foreign body in the right atrium. Lessons to Learn
Published in International journal of surgery case reports (2013)“…Abstract INTRODUCTION We report a case of a retained foreign body in the right atrium and the review of the literature discussing several cases where the poor…”
Get full text
Journal Article -
10
Consequence of Patient Substitution of Nattokinase for Warfarin After Aortic Valve Replacement with a Mechanical Prosthesis
Published in Proceedings - Baylor University. Medical Center (01-01-2015)“…This report describes a patient's self-substitution of nattokinase for the vitamin K antagonist warfarin after aortic valve replacement with a mechanical…”
Get full text
Journal Article -
11
-
12
Angiosarcoma of the right atrium presenting as hemoptysis
Published in Proceedings (Baylor University. Medical Center) (01-01-2016)Get full text
Report -
13
Consequence of patient substitution of nattokinase for warfarin after aortic valve replacement with a mechanical prosthesis
Published in Proceedings (Baylor University. Medical Center) (01-01-2015)“…This report describes a patient's self-substitution of nattokinase for the vitamin K antagonist warfarin after aortic valve replacement with a mechanical…”
Get full text
Report