Search Results - "Chen, Erli"
-
1
Fabrication of 10 nm enclosed nanofluidic channels
Published in Applied physics letters (01-07-2002)“…We made uniform arrays of nanometer scale structures using nanoimprint lithography over large areas (100 mm wafers). The nanofluidic channels were further…”
Get full text
Journal Article -
2
Clinical implementation of the first Cherenkov imaging system in a community-based hospital
Published in Technical innovations & patient support in radiation oncology (01-12-2022)“…To document experiences with one year of clinical implementation of the first Cherenkov imaging system and share the methods that we developed to utilize…”
Get full text
Journal Article -
3
Characteristics of coplanar transmission lines on multilayer substrates: modeling and experiments
Published in IEEE transactions on microwave theory and techniques (01-06-1997)“…Characteristics of coplanar transmission lines on multilayer substrates expressed in analytic formulas have been obtained using conformal mapping. The accuracy…”
Get full text
Journal Article -
4
The American Society for Radiation Oncology 2017 Radiation Oncologist Workforce Study
Published in International journal of radiation oncology, biology, physics (01-03-2019)“…The aim of this study is to report the American Society for Radiation Oncology 2017 radiation oncologist (RO) workforce survey results; identify demographic,…”
Get full text
Journal Article -
5
High-efficiency and high-speed silicon metal–semiconductor–metal photodetectors operating in the infrared
Published in Applied physics letters (10-02-1997)“…A silicon metal–semiconductor–metal photodetector with high-efficiency and high-speed in the infrared is reported. The high performance is achieved by using a…”
Get full text
Journal Article -
6
Performance comparison of quantitative metrics for analysis of in vivo Cherenkov imaging incident detection during radiotherapy
Published in British journal of radiology (01-09-2022)“…Examine the responses of multiple image similarity metrics to detect patient positioning errors in radiotherapy observed through Cherenkov imaging, which may…”
Get full text
Journal Article -
7
Abstract PR001: Radiation dose estimates via live, optical imaging are highly dependent upon patient skin tone
Published in Cancer epidemiology, biomarkers & prevention (01-12-2023)“…Abstract Introduction: New medical technologies must be tested across diverse populations to ensure efficacy for all patients. In the last decade, a novel…”
Get full text
Journal Article -
8
Failure Mode and Effects Analysis for Experimental Use of FLASH on a Clinical Accelerator
Published in Practical Radiation Oncology (01-03-2023)“…The use of a linear accelerator (LINAC) in ultrahigh-dose-rate (UHDR) mode can provide a conduit for wider access to UHDR FLASH effects, sparing normal tissue,…”
Get full text
Journal Article -
9
AAPM Medical Physics Practice Guideline 14.a: Yttrium‐90 microsphere radioembolization
Published in Journal of applied clinical medical physics (01-02-2024)“…Radioembolization using Yttrium‐90 (90Y) microspheres is widely used to treat primary and metastatic liver tumors. The present work provides minimum practice…”
Get full text
Journal Article -
10
One Year of Clinic-Wide Cherenkov Imaging for Discovery of Quality Improvement Opportunities in Radiation Therapy
Published in Practical Radiation Oncology (01-01-2023)“…Cherenkov imaging is clinically available as a radiation therapy treatment verification tool. The aim of this work was to discover the benefits of always-on…”
Get full text
Journal Article -
11
A special report of current state of the medical physicist workforce — results of the 2012 ASTRO Comprehensive Workforce Study
Published in Journal of applied clinical medical physics (08-05-2015)“…The medical physics profession is undergoing significant changes. Starting in 2014, candidates registering for certification exams by the American Board of…”
Get full text
Journal Article -
12
High-reflectivity self-pumped phase conjugator using total internal reflection in KNbNO3:Fe
Published in Applied physics letters (24-09-1990)“…A self-pumped phase conjugate reflectivity of 74.8% is obtained with a suitably cut KNbO3:Fe crystal in a polygonal shape. The design and operation of this…”
Get full text
Journal Article -
13
10 nm Si pillars fabricated using electron‐beam lithography, reactive ion etching, and HF etching
Published in Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures (01-11-1993)“…This article reports the fabrication and preliminary photoluminescence (PL) study of free‐standing Si pillars with diameters of about 10 nm and aspect ratios…”
Get full text
Conference Proceeding -
14
Failure Mode and Effects Analysis (FMEA) for Experimental Use of FLASH on a Clinical Accelerator
Published 20-12-2021“…Background: Use of a linear accelerator in ultra-high dose rate (UHDR) mode can provide a conduit for wider access to UHDR FLASH effects, sparing normal…”
Get full text
Journal Article -
15
Metal-semiconductor-metal photodetectors and coplanar transmission lines on SOI for high-speed interconnection
Get full text
Dissertation -
16
Retrospective Evaluation of an Always-on Cherenkov Imaging System for Radiotherapy Quality Improvement
Published 14-10-2021“…Purpose: Cherenkov imaging is now clinically available to track the course of radiation therapy as a treatment verification tool. The aim of this work was to…”
Get full text
Journal Article -
17
Polarimetry of thin metal transmission gratings in the resonance region and its impact on the response of metal-semiconductor-metal photodetectors
Published in Applied physics letters (19-05-1997)“…The resonance behavior of metal transmission gratings and its impact on the response of metal-semiconductor-metal (MSM) photodetectors have been studied…”
Get full text
Journal Article -
18
Junction edge instability in simple spin valve recording heads
Published in IEEE transactions on magnetics (01-09-2000)“…Baseline popping (BLP) and baseline shift (BLS) in simple GMR heads has been studied experimentally. The instability occurs mainly at the sensor's junction…”
Get full text
Journal Article Conference Proceeding -
19
Micro-magnetic and electric analysis on MR head baseline popping and instabilities
Published in IEEE transactions on magnetics (01-07-2001)“…A general explanation for four types of instabilities in magneto-resistive (MR) recording heads is given. A micro-magnetic analysis of the root causes of the…”
Get full text
Journal Article Conference Proceeding -
20
Metal-semiconductor-metal photodetectors and coplanar transmission lines on SOI for high-speed interconnection
Published 01-01-1997“…This thesis studies metal-semiconductor-metal (MSM) photodetectors and coplanar transmission lines (CTL's) on Si-on-insulator (SOI) for gigabit-per-second…”
Get full text
Dissertation